@@ -16,15 +16,15 @@ Arduino IDE version 2.x ([download](https://www.arduino.cc/en/software))
#### Version < 3.2.0
Using library manager install the latest version (Tools ➝ Manage Libraries... ➝ search for `"airgradient"`)
Using library manager install the latest version (Tools ➝ Manage Libraries... ➝ search for `"airgradient"`)
![Aigradient Library](images/ag-lib.png)
#### Version >= 3.3.0
- From your terminal, go to Arduino libraries folder (windows and mac: `Documents/Arduino/libraries` or linux: `~/Arduino/Libraries`).
- With **git** cli, execute this command `git clone --recursive https://github.com/airgradienthq/arduino.git AirGradient_Air_Quality_Sensor`
- Restart Arduino IDE
- With **git** cli, execute this command `git clone --recursive https://github.com/airgradienthq/arduino.git AirGradient_Air_Quality_Sensor`
- Restart Arduino IDE
3. On tools tab, follow settings below
@@ -57,7 +57,7 @@ Upload Speed ➝ 921600
![board manager](images/esp8266-board.png)
3. Install AirGradient library on library manager using the latest version (Tools ➝ Manage Libraries... ➝ search for `"airgradient"`)
3. Install AirGradient library on library manager using the latest version (Tools ➝ Manage Libraries... ➝ search for `"airgradient"`)
![Aigradient Library](images/ag-lib.png)
@@ -65,7 +65,7 @@ Upload Speed ➝ 921600
![settings esp8266](images/settings-esp8266.png)
5. Open sketch to compile (File ➝ Examples ➝ AirGradient Air Quality Sensor ➝ `<Model Option>`). Depends on the DIY model, either `BASIC`, `DiyProIndoorV3_3` and `DiyProIndoorV4_2`
5. Open sketch to compile (File ➝ Examples ➝ AirGradient Air Quality Sensor ➝ `<Model Option>`). Depends on the DIY model, either `BASIC`, `DiyProIndoorV3_3` and `DiyProIndoorV4_2`
6. Compile
![compiled esp8266](images/compiled-esp8266.png)
@@ -78,13 +78,13 @@ ModuleNotFoundError: No module named serial
![Linux Failed](images/linux-failed.png)
Make sure python pyserial module installed globally in the environment by executing:
Make sure python pyserial module installed globally in the environment by executing:
`$ sudo apt install -y python3-pyserial`
or
or
`$ pip install pyserial`
`$ pip install pyserial`
Choose based on how python installed on your machine. But most user, using `apt` is better.

View File

@@ -1,6 +1,6 @@
## Local Server API
From [firmware version 3.0.10](firmwares) onwards, the AirGradient ONE and Open Air monitors have below API available.
From [firmware version 3.0.10](firmwares) onwards, the AirGradient ONE and Open Air monitors have below API available.
### Discovery
@@ -20,7 +20,7 @@ http://airgradient_ecda3b1eaaaf.local/measures/current
“ecda3b1eaaaf” being the serial number of your monitor.
You get the following response:
```json
```json
{
"wifi": -46,
"serialno": "ecda3b1eaaaf",
@@ -84,7 +84,7 @@ Compensated values apply correction algorithms to make the sensor values more ac
"/config" path returns the current configuration of the monitor.
```json
```json
{
"country": "TH",
"pmStandard": "ugm3",
@@ -118,22 +118,22 @@ Configuration parameters can be changed with a PUT request to the monitor, e.g.
Example to force CO2 calibration
```bash
curl -X PUT -H "Content-Type: application/json" -d '{"co2CalibrationRequested":true}' http://airgradient_84fce612eff4.local/config
curl -X PUT -H "Content-Type: application/json" -d '{"co2CalibrationRequested":true}' http://airgradient_84fce612eff4.local/config
```
Example to set monitor to Celsius
```bash
curl -X PUT -H "Content-Type: application/json" -d '{"temperatureUnit":"c"}' http://airgradient_84fce612eff4.local/config
curl -X PUT -H "Content-Type: application/json" -d '{"temperatureUnit":"c"}' http://airgradient_84fce612eff4.local/config
```
If you use command prompt on Windows, you need to escape the quotes:
``` -d "{\"param\":\"value\"}" ```
### Avoiding Conflicts with Configuration on AirGradient Server
If the monitor is set up on the AirGradient dashboard, it will also receive the configuration parameters from there. In case you do not want this, please set `configurationControl` to `local`. In case you set it to `cloud` and want to change it to `local`, you need to make a factory reset.
If the monitor is set up on the AirGradient dashboard, it will also receive the configuration parameters from there. In case you do not want this, please set `configurationControl` to `local`. In case you set it to `cloud` and want to change it to `local`, you need to make a factory reset.
### Configuration Parameters (GET/PUT)
@@ -204,34 +204,34 @@ Example correction configuration:
Field Name: `pm02`
| Algorithm | Value | Description | SLR required |
|------------|-------------|------|---------|
|------------|-------------|------|---------|
| Raw | `"none"` | No correction (default) | No |
| EPA 2021 | `"epa_2021"` | Use EPA 2021 correction factors on top of raw value | No |
| PMS5003_20240104 | `"slr_PMS5003_20240104"` | Correction for PMS5003 sensor batch 20240104| Yes |
| PMS5003_20240104 | `"slr_PMS5003_20240104"` | Correction for PMS5003 sensor batch 20240104| Yes |
| PMS5003_20231218 | `"slr_PMS5003_20231218"` | Correction for PMS5003 sensor batch 20231218| Yes |
| PMS5003_20231030 | `"slr_PMS5003_20231030"` | Correction for PMS5003 sensor batch 20231030| Yes |
**NOTES**:
**NOTES**:
- Set `useEpa2021` to `true` if want to apply EPA 2021 correction factors on top of SLR correction value, otherwise `false`
- `intercept` and `scalingFactor` values can be obtained from [this article](https://www.airgradient.com/blog/low-readings-from-pms5003/)
- If `configurationControl` is set to `local` (eg. when using Home Assistant), correction need to be set manually, see examples below
- If `configurationControl` is set to `local` (eg. when using Home Assistant), correction need to be set manually, see examples below
**Examples**:
- PMS5003_20231030
- PMS5003_20231030
```bash
curl --location -X PUT 'http://airgradient_84fce612eff4.local/config' --header 'Content-Type: application/json' --data '{"corrections":{"pm02":{"correctionAlgorithm":"slr_PMS5003_20231030","slr":{"intercept":0,"scalingFactor":0.02838,"useEpa2021":true}}}}'
```
- PMS5003_20231218
- PMS5003_20231218
```bash
curl --location -X PUT 'http://airgradient_84fce612eff4.local/config' --header 'Content-Type: application/json' --data '{"corrections":{"pm02":{"correctionAlgorithm":"slr_PMS5003_20231218","slr":{"intercept":0,"scalingFactor":0.03525,"useEpa2021":true}}}}'
```
- PMS5003_20240104
- PMS5003_20240104
```bash
curl --location -X PUT 'http://airgradient_84fce612eff4.local/config' --header 'Content-Type: application/json' --data '{"corrections":{"pm02":{"correctionAlgorithm":"slr_PMS5003_20240104","slr":{"intercept":0,"scalingFactor":0.02896,"useEpa2021":true}}}}'
@@ -244,10 +244,10 @@ Field Name:
- Humidity: `rhum`
| Algorithm | Value | Description | SLR required |
|------------|-------------|------|---------|
|------------|-------------|------|---------|
| Raw | `"none"` | No correction (default) | No |
| AirGradient Standard Correction | `"ag_pms5003t_2024"` | Using standard airgradient correction (for outdoor monitor)| No |
| Custom | `"custom"` | custom corrections constant, set `intercept` and `scalingFactor` manually | Yes |
| Custom | `"custom"` | custom corrections constant, set `intercept` and `scalingFactor` manually | Yes |
*Table above apply for both Temperature and Humidity*

View File

@@ -1,6 +1,6 @@
## OTA Updates
From [firmware version 3.1.1](https://github.com/airgradienthq/arduino/tree/3.1.1) onwards, the AirGradient ONE and Open Air monitors support over the air (OTA) updates.
From [firmware version 3.1.1](https://github.com/airgradienthq/arduino/tree/3.1.1) onwards, the AirGradient ONE and Open Air monitors support over the air (OTA) updates.
#### Mechanism
@@ -10,7 +10,7 @@ The device attempts to update to the latest version on startup and in regular in
http://hw.airgradient.com/sensors/{deviceId}/generic/os/firmware.bin?current_firmware={GIT_VERSION}
If does pass the version it is currently running on along to the server through URL parameter 'current_firmware'.
If does pass the version it is currently running on along to the server through URL parameter 'current_firmware'.
This allows the server to identify if the device is already running on the latest version or should update.
The following scenarios are possible