From 4af77d532ed38e852c4baaec07272c9e5b61afea Mon Sep 17 00:00:00 2001 From: Phat Nguyen Date: Sat, 20 Jul 2024 09:39:29 +0700 Subject: [PATCH] Update local-server.md Quote properties name --- docs/local-server.md | 74 ++++++++++++++++++++++---------------------- 1 file changed, 37 insertions(+), 37 deletions(-) diff --git a/docs/local-server.md b/docs/local-server.md index 925117f..7092b35 100644 --- a/docs/local-server.md +++ b/docs/local-server.md @@ -47,27 +47,27 @@ You get the following response: | Properties | Type | Explanation | |------------------|--------|--------------------------------------------------------------------| -| serialno | String | Serial Number of the monitor | -| wifi | Number | WiFi signal strength | -| pm01 | Number | PM1 in ug/m3 | -| pm02 | Number | PM2.5 in ug/m3 | -| pm10 | Number | PM10 in ug/m3 | -| pm02Compensated | Number | PM2.5 in ug/m3 with correction applied (from fw version 3.1.4 onwards) | -| rco2 | Number | CO2 in ppm | -| pm003Count | Number | Particle count per dL | -| atmp | Number | Temperature in Degrees Celsius | -| atmpCompensated | Number | Temperature in Degrees Celsius with correction applied | -| rhum | Number | Relative Humidity | -| rhumCompensated | Number | Relative Humidity with correction applied | -| tvocIndex | Number | Senisiron VOC Index | -| tvocRaw | Number | VOC raw value | -| noxIndex | Number | Senisirion NOx Index | -| noxRaw | Number | NOx raw value | -| boot | Number | Counts every measurement cycle. Low boot counts indicate restarts. | -| bootCount | Number | Same as boot property. Required for Home Assistant compatability. Will be depreciated. | -| ledMode | String | Current configuration of the LED mode | -| firmware | String | Current firmware version | -| model | String | Current model name | +| `serialno` | String | Serial Number of the monitor | +| `wifi` | Number | WiFi signal strength | +| `pm01` | Number | PM1 in ug/m3 | +| `pm02` | Number | PM2.5 in ug/m3 | +| `pm10` | Number | PM10 in ug/m3 | +| `pm02Compensated` | Number | PM2.5 in ug/m3 with correction applied (from fw version 3.1.4 onwards) | +| `rco2` | Number | CO2 in ppm | +| `pm003Count` | Number | Particle count per dL | +| `atmp` | Number | Temperature in Degrees Celsius | +| `atmpCompensated` | Number | Temperature in Degrees Celsius with correction applied | +| `rhum` | Number | Relative Humidity | +| `rhumCompensated` | Number | Relative Humidity with correction applied | +| `tvocIndex` | Number | Senisiron VOC Index | +| `tvocRaw` | Number | VOC raw value | +| `noxIndex` | Number | Senisirion NOx Index | +| `noxRaw` | Number | NOx raw value | +| `boot` | Number | Counts every measurement cycle. Low boot counts indicate restarts. | +| `bootCount` | Number | Same as boot property. Required for Home Assistant compatability. Will be depreciated. | +| `ledMode` | String | Current configuration of the LED mode | +| `firmware` | String | Current firmware version | +| `model` | String | Current model name | Compensated values apply correction algorithms to make the sensor values more accurate. Temperature and relative humidity correction is only applied on the outdoor monitor Open Air but the properties _compensated will still be send also for the indoor monitor AirGradient ONE. @@ -108,19 +108,19 @@ If the monitor is set up on the AirGradient dashboard, it will also receive conf | Properties | Description | Type | Accepted Values | Example | |-------------------------|:-------------------------------------------------------|---------|-----------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------| -| country | Country where the device is. | String | Country code as [ALPHA-2 notation](https://www.iban.com/country-codes) | {"country": "TH"} | -| model | Hardware identifier (only GET). | String | I-9PSL-DE | {"model": "I-9PSL-DE"} | -| pmStandard | Particle matter standard used on the display. | String | `ugm3`: ug/m3
`us-aqi`: USAQI | {"pmStandard": "ugm3"} | -| ledBarMode | Mode in which the led bar can be set. | String | `co2`: LED bar displays CO2
`pm`: LED bar displays PM
`off`: Turn off LED bar | {"ledBarMode": "off"} | -| displayBrightness | Brightness of the Display. | Number | 0-100 | {"displayBrightness": 50} | -| ledBarBrightness | Brightness of the LEDBar. | Number | 0-100 | {"ledBarBrightness": 40} | -| abcDays | Number of days for CO2 automatic baseline calibration. | Number | Maximum 200 days. Default 8 days. | {"abcDays": 8} | -| mqttBrokerUrl | MQTT broker URL. | String | | {"mqttBrokerUrl": "mqtt://192.168.0.18:1883"} | -| temperatureUnit | Temperature unit shown on the display. | String | `c` or `C`: Degree Celsius °C
`f` or `F`: Degree Fahrenheit °F | {"temperatureUnit": "c"} | -| configurationControl | The configuration source of the device. | String | `both`: Accept local and cloud configuration
`local`: Accept only local configuration
`cloud`: Accept only cloud configuration | {"configurationControl": "both"} | -| postDataToAirGradient | Send data to AirGradient cloud. | Boolean | `true`: Enabled
`false`: Disabled | {"postDataToAirGradient": true} | -| co2CalibrationRequested | Can be set to trigger a calibration. | Boolean | `true`: CO2 calibration (400ppm) will be triggered | {"co2CalibrationRequested": true} | -| ledBarTestRequested | Can be set to trigger a test. | Boolean | `true` : LEDs will run test sequence | {"ledBarTestRequested": true} | -| noxLearningOffset | Set NOx learning gain offset. | Number | 0-720 (default 12) | {"noxLearningOffset": 12} | -| tvocLearningOffset | Set VOC learning gain offset. | Number | 0-720 (default 12) | {"tvocLearningOffset": 12} | -| offlineMode | Set monitor to run without WiFi. | Boolean | `false`: Disabled (default)
`true`: Enabled | {"offlineMode": true} | +| `country` | Country where the device is. | String | Country code as [ALPHA-2 notation](https://www.iban.com/country-codes) | {"country": "TH"} | +| `model` | Hardware identifier (only GET). | String | I-9PSL-DE | {"model": "I-9PSL-DE"} | +| `pmStandard` | Particle matter standard used on the display. | String | `ugm3`: ug/m3
`us-aqi`: USAQI | {"pmStandard": "ugm3"} | +| `ledBarMode` | Mode in which the led bar can be set. | String | `co2`: LED bar displays CO2
`pm`: LED bar displays PM
`off`: Turn off LED bar | {"ledBarMode": "off"} | +| `displayBrightness` | Brightness of the Display. | Number | 0-100 | {"displayBrightness": 50} | +| `ledBarBrightness` | Brightness of the LEDBar. | Number | 0-100 | {"ledBarBrightness": 40} | +| `abcDays` | Number of days for CO2 automatic baseline calibration. | Number | Maximum 200 days. Default 8 days. | {"abcDays": 8} | +| `mqttBrokerUrl` | MQTT broker URL. | String | | {"mqttBrokerUrl": "mqtt://192.168.0.18:1883"} | +| `temperatureUnit` | Temperature unit shown on the display. | String | `c` or `C`: Degree Celsius °C
`f` or `F`: Degree Fahrenheit °F | {"temperatureUnit": "c"} | +| `configurationControl` | The configuration source of the device. | String | `both`: Accept local and cloud configuration
`local`: Accept only local configuration
`cloud`: Accept only cloud configuration | {"configurationControl": "both"} | +| `postDataToAirGradient` | Send data to AirGradient cloud. | Boolean | `true`: Enabled
`false`: Disabled | {"postDataToAirGradient": true} | +| `co2CalibrationRequested` | Can be set to trigger a calibration. | Boolean | `true`: CO2 calibration (400ppm) will be triggered | {"co2CalibrationRequested": true} | +| `ledBarTestRequested` | Can be set to trigger a test. | Boolean | `true` : LEDs will run test sequence | {"ledBarTestRequested": true} | +| `noxLearningOffset` | Set NOx learning gain offset. | Number | 0-720 (default 12) | {"noxLearningOffset": 12} | +| `tvocLearningOffset` | Set VOC learning gain offset. | Number | 0-720 (default 12) | {"tvocLearningOffset": 12} | +| `offlineMode` | Set monitor to run without WiFi. | Boolean | `false`: Disabled (default)
`true`: Enabled | {"offlineMode": true} |