diff --git a/docs/local-server.md b/docs/local-server.md
index a67938a..78eeadc 100644
--- a/docs/local-server.md
+++ b/docs/local-server.md
@@ -95,15 +95,15 @@ If the monitor is setup on the AirGradient dashboard, it will also receive confi
#### Configuration Parameters (GET/PUT)
-|Properties|Type|Accepted Values|Example|
-|-|-|-|-|
-|country|String| Country code as [ALPHA-2 notation](https://www.iban.com/country-codes) | {"country": "TH"}|
-|pmStandard|String|ugm3 : ug/m3
usaqi: USAQI | {"pmStandard": "ugm3"}|
-|ledBarMode|String|co2: LED bar displays CO2
pm: LED bar displays PM
off: Turn off LED bar | {"ledBarMode": "off"}|
-|abcDays|Number|Number of days for CO2 automatic baseline balibration. Maximum 200 days. Default 8 days. | {"abcDays": 8}|
-|mqttBrokerUrl|String|MQTT broker URL. | {"mqttBrokerUrl":"mqtt://192.168.0.18:1883"} |
-|temperatureUnit|String|c or C: Degree Celsius °C
f or F: Degree Fahrenheit °F | {"temperatureUnit": "c"}|
-|configurationControl|String|both : Accept local and cloud configuration
local : Accept only local configuration
cloud : Accept only cloud configuration | {"configurationControl": "both"}|
-|postDataToAirGradient|Boolean|Send data to AirGradient cloud:
true : Enabled
false: Disabled | {"postDataToAirGradient": true}|
-|co2CalibrationRequested|Boolean|Trigger CO2 calibration (400ppm) on monitor:
true : Calibration will be triggered | {"co2CalibrationRequested": true}|
-|ledBarTestRequested|Boolean|Test LED bar:
true : LEDs will run test sequence | {"ledBarTestRequested": true}|
+| Properties | Description | Type | Accepted Values | Example |
+|-------------------------|:-------------------------------------------------------|---------|-----------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------|
+| country | Country where the device is. | String | Country code as [ALPHA-2 notation](https://www.iban.com/country-codes) | {"country": "TH"} |
+| pmStandard | Particle matter standard used on the display. | String | `ugm3`: ug/m3
`us-aqi`: USAQI | {"pmStandard": "ugm3"} |
+| ledBarMode | Mode in which the led bar can be set. | String | `co2`: LED bar displays CO2
`pm`: LED bar displays PM
`off`: Turn off LED bar | {"ledBarMode": "off"} |
+| abcDays | Number of days for CO2 automatic baseline calibration. | Number | Maximum 200 days. Default 8 days. | {"abcDays": 8} |
+| mqttBrokerUrl | MQTT broker URL. | String | | {"mqttBrokerUrl": "mqtt://192.168.0.18:1883"} |
+| temperatureUnit | Temperature unit shown on the display. | String | `c` or `C`: Degree Celsius °C
`f` or `F`: Degree Fahrenheit °F | {"temperatureUnit": "c"} |
+| configurationControl | The configuration source of the device. | String | `both`: Accept local and cloud configuration
`local`: Accept only local configuration
`cloud`: Accept only cloud configuration | {"configurationControl": "both"} |
+| postDataToAirGradient | Send data to AirGradient cloud. | Boolean | `true`: Enabled
`false`: Disabled | {"postDataToAirGradient": true} |
+| co2CalibrationRequested | Can be set to trigger a calibration. | Boolean | `true`: CO2 calibration (400ppm) will be triggered | {"co2CalibrationRequested": true} |
+| ledBarTestRequested | Can be set to trigger a test. | Boolean | `true` : LEDs will run test sequence | {"ledBarTestRequested": true} |