Changed measurement and update intervalls

This commit is contained in:
Achim
2024-03-02 14:05:00 +07:00
parent 1eb43f684b
commit c1228bbd06
3 changed files with 5 additions and 6 deletions

View File

@ -90,13 +90,13 @@ enum {
#define WIFI_CONNECT_RETRY_MS 10000 /** ms */
#define LED_BAR_COUNT_INIT_VALUE (-1) /** */
#define LED_BAR_ANIMATION_PERIOD 100 /** ms */
#define DISP_UPDATE_INTERVAL 5000 /** ms */
#define SERVER_CONFIG_UPDATE_INTERVAL 30000 /** ms */
#define DISP_UPDATE_INTERVAL 2500 /** ms */
#define SERVER_CONFIG_UPDATE_INTERVAL 15000 /** ms */
#define SERVER_SYNC_INTERVAL 60000 /** ms */
#define MQTT_SYNC_INTERVAL 60000 /** ms */
#define SENSOR_CO2_CALIB_COUNTDOWN_MAX 5 /** sec */
#define SENSOR_TVOC_UPDATE_INTERVAL 1000 /** ms */
#define SENSOR_CO2_UPDATE_INTERVAL 5000 /** ms */
#define SENSOR_CO2_UPDATE_INTERVAL 4000 /** ms */
#define SENSOR_PM_UPDATE_INTERVAL 2000 /** ms */
#define SENSOR_TEMP_HUM_UPDATE_INTERVAL 2000 /** ms */
#define DISPLAY_DELAY_SHOW_CONTENT_MS 2000 /** ms */
@ -2239,7 +2239,6 @@ static void sendDataToServer(void) {
* @brief Update temperature and humidity value
*/
static void tempHumUpdate(void) {
Serial.println("Try SHT");
if (ag.sht.measure()) {
temp = ag.sht.getTemperature();

View File

@ -1,5 +1,5 @@
name=AirGradient Air Quality Sensor
version=3.0.5
version=3.0.6
author=AirGradient <support@airgradient.com>
maintainer=AirGradient <support@airgradient.com>
sentence=ESP32-C3 / ESP8266 library for air quality monitor measuring PM, CO2, Temperature, TVOC and Humidity with OLED display.

View File

@ -1,6 +1,6 @@
#include "AirGradient.h"
#define AG_LIB_VER "3.0.5"
#define AG_LIB_VER "3.0.6"
AirGradient::AirGradient(BoardType type)
: pms5003(type), pms5003t_1(type), pms5003t_2(type), s8(type), sgp41(type),