#include "OpenMetrics.h"
|
||||
|
||||
OpenMetrics::OpenMetrics(Measurements &measure, Configuration &config,
|
||||
WifiConnector &wifiConnector, AgApiClient &apiClient)
|
||||
: measure(measure), config(config), wifiConnector(wifiConnector),
|
||||
apiClient(apiClient) {}
|
||||
|
||||
OpenMetrics::~OpenMetrics() {}
|
||||
|
||||
void OpenMetrics::setAirGradient(AirGradient *ag) { this->ag = ag; }
|
||||
|
||||
const char *OpenMetrics::getApiContentType(void) {
|
||||
return "application/openmetrics-text; version=1.0.0; charset=utf-8";
|
||||
}
|
||||
|
||||
const char *OpenMetrics::getApi(void) { return "/metrics"; }
|
||||
|
||||
String OpenMetrics::getPayload(void) {
|
||||
String response;
|
||||
String current_metric_name;
|
||||
const auto add_metric = [&](const String &name, const String &help,
|
||||
const String &type, const String &unit = "") {
|
||||
current_metric_name = "airgradient_" + name;
|
||||
if (!unit.isEmpty())
|
||||
current_metric_name += "_" + unit;
|
||||
response += "# HELP " + current_metric_name + " " + help + "\n";
|
||||
response += "# TYPE " + current_metric_name + " " + type + "\n";
|
||||
if (!unit.isEmpty())
|
||||
response += "# UNIT " + current_metric_name + " " + unit + "\n";
|
||||
};
|
||||
const auto add_metric_point = [&](const String &labels, const String &value) {
|
||||
response += current_metric_name + "{" + labels + "} " + value + "\n";
|
||||
};
|
||||
|
||||
add_metric("info", "AirGradient device information", "info");
|
||||
add_metric_point("airgradient_serial_number=\"" + ag->deviceId() +
|
||||
"\",airgradient_device_type=\"" + ag->getBoardName() +
|
||||
"\",airgradient_library_version=\"" + ag->getVersion() +
|
||||
"\"",
|
||||
"1");
|
||||
|
||||
add_metric("config_ok",
|
||||
"1 if the AirGradient device was able to successfully fetch its "
|
||||
"configuration from the server",
|
||||
"gauge");
|
||||
add_metric_point("", apiClient.isFetchConfigureFailed() ? "0" : "1");
|
||||
|
||||
add_metric(
|
||||
"post_ok",
|
||||
"1 if the AirGradient device was able to successfully send to the server",
|
||||
"gauge");
|
||||
add_metric_point("", apiClient.isPostToServerFailed() ? "0" : "1");
|
||||
|
||||
add_metric(
|
||||
"wifi_rssi",
|
||||
"WiFi signal strength from the AirGradient device perspective, in dBm",
|
||||
"gauge", "dbm");
|
||||
add_metric_point("", String(wifiConnector.RSSI()));
|
||||
|
||||
if (config.hasSensorS8 && measure.CO2 >= 0) {
|
||||
add_metric("co2",
|
||||
"Carbon dioxide concentration as measured by the AirGradient S8 "
|
||||
"sensor, in parts per million",
|
||||
"gauge", "ppm");
|
||||
add_metric_point("", String(measure.CO2));
|
||||
}
|
||||
|
||||
float _temp = -1001;
|
||||
float _hum = -1;
|
||||
int pm01 = -1;
|
||||
int pm25 = -1;
|
||||
int pm10 = -1;
|
||||
int pm03PCount = -1;
|
||||
int atmpCompensated = -1;
|
||||
int ahumCompensated = -1;
|
||||
|
||||
if (config.hasSensorSHT) {
|
||||
_temp = measure.Temperature;
|
||||
_hum = measure.Humidity;
|
||||
atmpCompensated = _temp;
|
||||
ahumCompensated = _hum;
|
||||
}
|
||||
|
||||
if (config.hasSensorPMS1) {
|
||||
pm01 = measure.pm01_1;
|
||||
pm25 = measure.pm25_1;
|
||||
pm10 = measure.pm10_1;
|
||||
pm03PCount = measure.pm03PCount_1;
|
||||
}
|
||||
|
||||
if (config.hasSensorPMS1) {
|
||||
if (pm01 >= 0) {
|
||||
add_metric("pm1",
|
||||
"PM1.0 concentration as measured by the AirGradient PMS "
|
||||
"sensor, in micrograms per cubic meter",
|
||||
"gauge", "ugm3");
|
||||
add_metric_point("", String(pm01));
|
||||
}
|
||||
if (pm25 >= 0) {
|
||||
add_metric("pm2d5",
|
||||
"PM2.5 concentration as measured by the AirGradient PMS "
|
||||
"sensor, in micrograms per cubic meter",
|
||||
"gauge", "ugm3");
|
||||
add_metric_point("", String(pm25));
|
||||
}
|
||||
if (pm10 >= 0) {
|
||||
add_metric("pm10",
|
||||
"PM10 concentration as measured by the AirGradient PMS "
|
||||
"sensor, in micrograms per cubic meter",
|
||||
"gauge", "ugm3");
|
||||
add_metric_point("", String(pm10));
|
||||
}
|
||||
if (pm03PCount >= 0) {
|
||||
add_metric("pm0d3",
|
||||
"PM0.3 concentration as measured by the AirGradient PMS "
|
||||
"sensor, in number of particules per 100 milliliters",
|
||||
"gauge", "p100ml");
|
||||
add_metric_point("", String(pm03PCount));
|
||||
}
|
||||
}
|
||||
|
||||
if (config.hasSensorSGP) {
|
||||
if (measure.TVOC >= 0) {
|
||||
add_metric("tvoc_index",
|
||||
"The processed Total Volatile Organic Compounds (TVOC) index "
|
||||
"as measured by the AirGradient SGP sensor",
|
||||
"gauge");
|
||||
add_metric_point("", String(measure.TVOC));
|
||||
}
|
||||
if (measure.TVOCRaw >= 0) {
|
||||
add_metric("tvoc_raw",
|
||||
"The raw input value to the Total Volatile Organic Compounds "
|
||||
"(TVOC) index as measured by the AirGradient SGP sensor",
|
||||
"gauge");
|
||||
add_metric_point("", String(measure.TVOCRaw));
|
||||
}
|
||||
if (measure.NOx >= 0) {
|
||||
add_metric("nox_index",
|
||||
"The processed Nitrous Oxide (NOx) index as measured by the "
|
||||
"AirGradient SGP sensor",
|
||||
"gauge");
|
||||
add_metric_point("", String(measure.NOx));
|
||||
}
|
||||
if (measure.NOxRaw >= 0) {
|
||||
add_metric("nox_raw",
|
||||
"The raw input value to the Nitrous Oxide (NOx) index as "
|
||||
"measured by the AirGradient SGP sensor",
|
||||
"gauge");
|
||||
add_metric_point("", String(measure.NOxRaw));
|
||||
}
|
||||
}
|
||||
|
||||
if (_temp > -1001) {
|
||||
add_metric(
|
||||
"temperature",
|
||||
"The ambient temperature as measured by the AirGradient SHT / PMS "
|
||||
"sensor, in degrees Celsius",
|
||||
"gauge", "celsius");
|
||||
add_metric_point("", String(_temp));
|
||||
}
|
||||
if (atmpCompensated > -1001) {
|
||||
add_metric("temperature_compensated",
|
||||
"The compensated ambient temperature as measured by the "
|
||||
"AirGradient SHT / PMS "
|
||||
"sensor, in degrees Celsius",
|
||||
"gauge", "celsius");
|
||||
add_metric_point("", String(atmpCompensated));
|
||||
}
|
||||
if (_hum >= 0) {
|
||||
add_metric(
|
||||
"humidity",
|
||||
"The relative humidity as measured by the AirGradient SHT sensor",
|
||||
"gauge", "percent");
|
||||
add_metric_point("", String(_hum));
|
||||
}
|
||||
if (ahumCompensated >= 0) {
|
||||
add_metric("humidity_compensated",
|
||||
"The compensated relative humidity as measured by the "
|
||||
"AirGradient SHT / PMS sensor",
|
||||
"gauge", "percent");
|
||||
add_metric_point("", String(ahumCompensated));
|
||||
}
|
||||
|
||||
response += "# EOF\n";
|
||||