											2022-08-08 21:56:49 +08:00
										 |  |  | /*
 | 
					
						
							| 
									
										
										
										
											2024-10-10 21:10:20 +08:00
										 |  |  |  * SPDX-FileCopyrightText: 2022-2024 Espressif Systems (Shanghai) CO LTD | 
					
						
							| 
									
										
										
										
											2022-08-08 21:56:49 +08:00
										 |  |  |  * | 
					
						
							|  |  |  |  * SPDX-License-Identifier: Apache-2.0 | 
					
						
							|  |  |  |  */ | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | #include "soc/ledc_periph.h"
 | 
					
						
							|  |  |  | #include "soc/gpio_sig_map.h"
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | /*
 | 
					
						
							|  |  |  |  Bunch of constants for every LEDC peripheral: GPIO signals | 
					
						
							|  |  |  | */ | 
					
						
							|  |  |  | const ledc_signal_conn_t ledc_periph_signal[1] = { | 
					
						
							| 
									
										
										
										
											2024-11-22 10:55:08 +08:00
										 |  |  |     { | 
					
						
							| 
									
										
										
										
											2022-08-08 21:56:49 +08:00
										 |  |  |         .sig_out0_idx = LEDC_LS_SIG_OUT0_IDX, | 
					
						
							| 
									
										
										
										
											2024-11-22 10:55:08 +08:00
										 |  |  |     } | 
					
						
							| 
									
										
										
										
											2022-08-08 21:56:49 +08:00
										 |  |  | }; | 
					
						
							| 
									
										
										
										
											2024-10-10 21:10:20 +08:00
										 |  |  | 
 | 
					
						
							|  |  |  | /**
 | 
					
						
							|  |  |  |  * LEDC registers to be saved for sleep retention | 
					
						
							|  |  |  |  * | 
					
						
							|  |  |  |  * channel: | 
					
						
							|  |  |  |  * LEDC_CHx_CONF0_REG, LEDC_CHx_HPOINT_REG, LEDC_CHx_DUTY_R_REG -> LEDC_CHx_DUTY_REG, | 
					
						
							|  |  |  |  * | 
					
						
							|  |  |  |  * timer: | 
					
						
							|  |  |  |  * LEDC_TIMERn_CONF_REG, LEDC_TIMERn_CMP_REG, | 
					
						
							|  |  |  |  * | 
					
						
							|  |  |  |  * common: | 
					
						
							|  |  |  |  * LEDC_INT_ENA_REG, | 
					
						
							|  |  |  |  * LEDC_EVT_TASK_EN0_REG, LEDC_EVT_TASK_EN1_REG, LEDC_EVT_TASK_EN2_REG, | 
					
						
							|  |  |  |  * LEDC_CONF_REG, | 
					
						
							|  |  |  |  * | 
					
						
							|  |  |  |  * Note 1: Gamma feature is hard to do hardware retention, will consider to use software to do the backup and restore. | 
					
						
							| 
									
										
										
										
											2024-11-22 10:55:08 +08:00
										 |  |  |  *         We won't start a fade automatically after wake-up. | 
					
						
							| 
									
										
										
										
											2024-10-18 17:32:18 +08:00
										 |  |  |  *         Instead, we will only start a PWM with a fixed duty cycle, the same value as before entering the sleep. | 
					
						
							| 
									
										
										
										
											2024-10-10 21:10:20 +08:00
										 |  |  |  * | 
					
						
							|  |  |  |  * Note 2: For timer/channel registers to get synced, update bits need to be set | 
					
						
							| 
									
										
										
										
											2024-10-18 17:32:18 +08:00
										 |  |  |  * | 
					
						
							|  |  |  |  * Note 3: Retention backup/restore does not rely on LEDC function clock enabled | 
					
						
							| 
									
										
										
										
											2024-10-10 21:10:20 +08:00
										 |  |  |  */ | 
					
						
							|  |  |  | #define LEDC_COMMON_RETENTION_REGS_CNT  5
 | 
					
						
							|  |  |  | #define LEDC_COMMON_RETENTION_REGS_BASE (DR_REG_LEDC_BASE + 0xc8)
 | 
					
						
							|  |  |  | static const uint32_t ledc_common_regs_map[4] = {0x1, 0x1c00000, 0x400, 0x0}; | 
					
						
							|  |  |  | static const regdma_entries_config_t ledc_common_regdma_entries[] = { | 
					
						
							| 
									
										
										
										
											2024-11-22 10:55:08 +08:00
										 |  |  |     // If a fade is in process, the DUTY_CHNG_END_CHx intr bit is enabled, however, we don't want it to be restored after wake-up (no fade after wake-up).
 | 
					
						
							| 
									
										
										
										
											2024-10-10 21:10:20 +08:00
										 |  |  |     // Therefore, we can set it to 0 before backup the LEDC_INT_ENA_REG.
 | 
					
						
							| 
									
										
										
										
											2024-11-22 10:55:08 +08:00
										 |  |  |     [0] = { | 
					
						
							|  |  |  |         .config = REGDMA_LINK_WRITE_INIT(REGDMA_LEDC_LINK(0x00), | 
					
						
							|  |  |  |                                          LEDC_INT_ENA_REG, 0, | 
					
						
							|  |  |  |                                          (LEDC_DUTY_CHNG_END_CH0_INT_ENA_M | LEDC_DUTY_CHNG_END_CH1_INT_ENA_M | LEDC_DUTY_CHNG_END_CH2_INT_ENA_M | LEDC_DUTY_CHNG_END_CH3_INT_ENA_M | LEDC_DUTY_CHNG_END_CH4_INT_ENA_M | LEDC_DUTY_CHNG_END_CH5_INT_ENA_M), 0, 1), | 
					
						
							|  |  |  |         .owner = LEDC_RETENTION_ENTRY | 
					
						
							|  |  |  |     }, | 
					
						
							|  |  |  |     [1] = { | 
					
						
							|  |  |  |         .config = REGDMA_LINK_ADDR_MAP_INIT(REGDMA_LEDC_LINK(0x01), | 
					
						
							|  |  |  |                                             LEDC_COMMON_RETENTION_REGS_BASE, LEDC_COMMON_RETENTION_REGS_BASE, | 
					
						
							|  |  |  |                                             LEDC_COMMON_RETENTION_REGS_CNT, 0, 0, | 
					
						
							|  |  |  |                                             ledc_common_regs_map[0], ledc_common_regs_map[1], | 
					
						
							|  |  |  |                                             ledc_common_regs_map[2], ledc_common_regs_map[3]), | 
					
						
							|  |  |  |         .owner = LEDC_RETENTION_ENTRY | 
					
						
							|  |  |  |     }, | 
					
						
							| 
									
										
										
										
											2024-10-10 21:10:20 +08:00
										 |  |  | }; | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | #define LEDC_TIMER_RETENTION_ENTRIES(timer) { \
 | 
					
						
							| 
									
										
										
										
											2024-11-22 10:55:08 +08:00
										 |  |  |     [0] = { .config = REGDMA_LINK_CONTINUOUS_INIT(REGDMA_LEDC_LINK(0x00), \ | 
					
						
							|  |  |  |                                                  LEDC_TIMER##timer##_CONF_REG, LEDC_TIMER##timer##_CONF_REG, \ | 
					
						
							|  |  |  |                                                  1, 0, 0), \ | 
					
						
							|  |  |  |             .owner = LEDC_RETENTION_ENTRY }, \ | 
					
						
							|  |  |  |     [1] = { .config = REGDMA_LINK_CONTINUOUS_INIT(REGDMA_LEDC_LINK(0x01), \ | 
					
						
							|  |  |  |                                                  LEDC_TIMER##timer##_CMP_REG, LEDC_TIMER##timer##_CMP_REG, \ | 
					
						
							|  |  |  |                                                  1, 0, 0), \ | 
					
						
							|  |  |  |             .owner = LEDC_RETENTION_ENTRY }, \ | 
					
						
							|  |  |  |     [2] = { .config = REGDMA_LINK_WRITE_INIT(REGDMA_LEDC_LINK(0x02), \ | 
					
						
							|  |  |  |                                             LEDC_TIMER##timer##_CONF_REG, LEDC_TIMER##timer##_PARA_UP, \ | 
					
						
							|  |  |  |                                             LEDC_TIMER##timer##_PARA_UP_M, 1, 0), \ | 
					
						
							|  |  |  |             .owner = LEDC_RETENTION_ENTRY }, \ | 
					
						
							| 
									
										
										
										
											2024-10-10 21:10:20 +08:00
										 |  |  | } | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | #define LEDC_CHANNEL_RETENTION_REGS_CNT 2
 | 
					
						
							|  |  |  | static const uint32_t ledc_channel_regs_map[4] = {0x3, 0x0, 0x0, 0x0}; | 
					
						
							|  |  |  | #define LEDC_CHANNEL_RETENTION_ENTRIES(chan) { \
 | 
					
						
							| 
									
										
										
										
											2024-11-22 10:55:08 +08:00
										 |  |  |     [0] = { .config = REGDMA_LINK_ADDR_MAP_INIT(REGDMA_LEDC_LINK(0x00), \ | 
					
						
							| 
									
										
										
										
											2024-10-10 21:10:20 +08:00
										 |  |  |                                                LEDC_CH##chan##_CONF0_REG, LEDC_CH##chan##_CONF0_REG, \ | 
					
						
							|  |  |  |                                                LEDC_CHANNEL_RETENTION_REGS_CNT, 0, 0, \ | 
					
						
							|  |  |  |                                                ledc_channel_regs_map[0], ledc_channel_regs_map[1], \ | 
					
						
							|  |  |  |                                                ledc_channel_regs_map[2], ledc_channel_regs_map[3]), \ | 
					
						
							|  |  |  |             .owner = LEDC_RETENTION_ENTRY }, \ | 
					
						
							| 
									
										
										
										
											2024-11-22 10:55:08 +08:00
										 |  |  |     [1] = { .config = REGDMA_LINK_CONTINUOUS_INIT(REGDMA_LEDC_LINK(0x01), \ | 
					
						
							| 
									
										
										
										
											2024-10-10 21:10:20 +08:00
										 |  |  |                                                  LEDC_CH##chan##_DUTY_R_REG, LEDC_CH##chan##_DUTY_REG, \ | 
					
						
							|  |  |  |                                                  1, 0, 0), \ | 
					
						
							|  |  |  |             .owner = LEDC_RETENTION_ENTRY }, \ | 
					
						
							| 
									
										
										
										
											2024-11-22 10:55:08 +08:00
										 |  |  |     [2] = { .config = REGDMA_LINK_WRITE_INIT(REGDMA_LEDC_LINK(0x02), \ | 
					
						
							|  |  |  |                                             LEDC_CH##chan##_CONF1_REG, LEDC_DUTY_START_CH##chan, \ | 
					
						
							|  |  |  |                                             LEDC_DUTY_START_CH##chan##_M, 1, 0), \ | 
					
						
							|  |  |  |             .owner = LEDC_RETENTION_ENTRY }, \ | 
					
						
							|  |  |  |     [3] = { .config = REGDMA_LINK_WRITE_INIT(REGDMA_LEDC_LINK(0x03), \ | 
					
						
							|  |  |  |                                             LEDC_CH##chan##_CONF0_REG, LEDC_PARA_UP_CH##chan, \ | 
					
						
							|  |  |  |                                             LEDC_PARA_UP_CH##chan##_M, 1, 0), \ | 
					
						
							|  |  |  |             .owner = LEDC_RETENTION_ENTRY }, \ | 
					
						
							| 
									
										
										
										
											2024-10-10 21:10:20 +08:00
										 |  |  | } | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | static const regdma_entries_config_t ledc_timer0_regdma_entries[] = LEDC_TIMER_RETENTION_ENTRIES(0); | 
					
						
							|  |  |  | static const regdma_entries_config_t ledc_timer1_regdma_entries[] = LEDC_TIMER_RETENTION_ENTRIES(1); | 
					
						
							|  |  |  | static const regdma_entries_config_t ledc_timer2_regdma_entries[] = LEDC_TIMER_RETENTION_ENTRIES(2); | 
					
						
							|  |  |  | static const regdma_entries_config_t ledc_timer3_regdma_entries[] = LEDC_TIMER_RETENTION_ENTRIES(3); | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | static const regdma_entries_config_t ledc_channel0_regdma_entries[] = LEDC_CHANNEL_RETENTION_ENTRIES(0); | 
					
						
							|  |  |  | static const regdma_entries_config_t ledc_channel1_regdma_entries[] = LEDC_CHANNEL_RETENTION_ENTRIES(1); | 
					
						
							|  |  |  | static const regdma_entries_config_t ledc_channel2_regdma_entries[] = LEDC_CHANNEL_RETENTION_ENTRIES(2); | 
					
						
							|  |  |  | static const regdma_entries_config_t ledc_channel3_regdma_entries[] = LEDC_CHANNEL_RETENTION_ENTRIES(3); | 
					
						
							|  |  |  | static const regdma_entries_config_t ledc_channel4_regdma_entries[] = LEDC_CHANNEL_RETENTION_ENTRIES(4); | 
					
						
							|  |  |  | static const regdma_entries_config_t ledc_channel5_regdma_entries[] = LEDC_CHANNEL_RETENTION_ENTRIES(5); | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | const ledc_reg_retention_info_t ledc_reg_retention_info = { | 
					
						
							| 
									
										
										
										
											2024-11-22 10:55:08 +08:00
										 |  |  |     .common = { | 
					
						
							|  |  |  |         .regdma_entry_array = ledc_common_regdma_entries, | 
					
						
							|  |  |  |         .array_size = ARRAY_SIZE(ledc_common_regdma_entries), | 
					
						
							|  |  |  |     }, | 
					
						
							|  |  |  |     .timer[0] = { | 
					
						
							|  |  |  |         .regdma_entry_array = ledc_timer0_regdma_entries, | 
					
						
							|  |  |  |         .array_size = ARRAY_SIZE(ledc_timer0_regdma_entries), | 
					
						
							|  |  |  |     }, | 
					
						
							|  |  |  |     .timer[1] = { | 
					
						
							|  |  |  |         .regdma_entry_array = ledc_timer1_regdma_entries, | 
					
						
							|  |  |  |         .array_size = ARRAY_SIZE(ledc_timer1_regdma_entries), | 
					
						
							|  |  |  |     }, | 
					
						
							|  |  |  |     .timer[2] = { | 
					
						
							|  |  |  |         .regdma_entry_array = ledc_timer2_regdma_entries, | 
					
						
							|  |  |  |         .array_size = ARRAY_SIZE(ledc_timer2_regdma_entries), | 
					
						
							|  |  |  |     }, | 
					
						
							|  |  |  |     .timer[3] = { | 
					
						
							|  |  |  |         .regdma_entry_array = ledc_timer3_regdma_entries, | 
					
						
							|  |  |  |         .array_size = ARRAY_SIZE(ledc_timer3_regdma_entries), | 
					
						
							|  |  |  |     }, | 
					
						
							|  |  |  |     .channel[0] = { | 
					
						
							|  |  |  |         .regdma_entry_array = ledc_channel0_regdma_entries, | 
					
						
							|  |  |  |         .array_size = ARRAY_SIZE(ledc_channel0_regdma_entries), | 
					
						
							|  |  |  |     }, | 
					
						
							|  |  |  |     .channel[1] = { | 
					
						
							|  |  |  |         .regdma_entry_array = ledc_channel1_regdma_entries, | 
					
						
							|  |  |  |         .array_size = ARRAY_SIZE(ledc_channel1_regdma_entries), | 
					
						
							|  |  |  |     }, | 
					
						
							|  |  |  |     .channel[2] = { | 
					
						
							|  |  |  |         .regdma_entry_array = ledc_channel2_regdma_entries, | 
					
						
							|  |  |  |         .array_size = ARRAY_SIZE(ledc_channel2_regdma_entries), | 
					
						
							|  |  |  |     }, | 
					
						
							|  |  |  |     .channel[3] = { | 
					
						
							|  |  |  |         .regdma_entry_array = ledc_channel3_regdma_entries, | 
					
						
							|  |  |  |         .array_size = ARRAY_SIZE(ledc_channel3_regdma_entries), | 
					
						
							|  |  |  |     }, | 
					
						
							|  |  |  |     .channel[4] = { | 
					
						
							|  |  |  |         .regdma_entry_array = ledc_channel4_regdma_entries, | 
					
						
							|  |  |  |         .array_size = ARRAY_SIZE(ledc_channel4_regdma_entries), | 
					
						
							|  |  |  |     }, | 
					
						
							|  |  |  |     .channel[5] = { | 
					
						
							|  |  |  |         .regdma_entry_array = ledc_channel5_regdma_entries, | 
					
						
							|  |  |  |         .array_size = ARRAY_SIZE(ledc_channel5_regdma_entries), | 
					
						
							|  |  |  |     }, | 
					
						
							|  |  |  |     .module_id = SLEEP_RETENTION_MODULE_LEDC, | 
					
						
							| 
									
										
										
										
											2024-10-10 21:10:20 +08:00
										 |  |  | }; |