#!/usr/bin/env python
# import normal packages
import platform
import logging
import sys
import os
import sys
if sys.version_info.major == 2:
import gobject
else:
from gi.repository import GLib as gobject
import sys
import time
import requests # for http GET
import configparser # for config/ini file
# our own packages from victron
sys.path.insert(1, os.path.join(os.path.dirname(__file__), '/opt/victronenergy/dbus-systemcalc-py/ext/velib_python'))
from vedbus import VeDbusService
class DbusGoeChargerService:
def __init__(self, servicename, paths, productname='go-eCharger', connection='go-eCharger HTTP JSON service'):
config = self._getConfig()
deviceinstance = int(config['DEFAULT']['Deviceinstance'])
hardwareVersion = int(config['DEFAULT']['HardwareVersion'])
self._dbusservice = VeDbusService("{}.http_{:02d}".format(servicename, deviceinstance))
self._paths = paths
logging.debug("%s /DeviceInstance = %d" % (servicename, deviceinstance))
paths_wo_unit = [
'/Status', # value 'car' 1: charging station ready, no vehicle 2: vehicle loads 3: Waiting for vehicle 4: Charge finished, vehicle still connected
'/Mode'
]
#get data from go-eCharger
data = self._getGoeChargerData()
# Create the management objects, as specified in the ccgx dbus-api document
self._dbusservice.add_path('/Mgmt/ProcessName', __file__)
self._dbusservice.add_path('/Mgmt/ProcessVersion', 'Unkown version, and running on Python ' + platform.python_version())
self._dbusservice.add_path('/Mgmt/Connection', connection)
# Create the mandatory objects
self._dbusservice.add_path('/DeviceInstance', deviceinstance)
self._dbusservice.add_path('/ProductId', 0xFFFF) #
self._dbusservice.add_path('/ProductName', productname)
self._dbusservice.add_path('/CustomName', productname)
if data:
self._dbusservice.add_path('/FirmwareVersion', int(data['fwv'].replace('.', '')))
self._dbusservice.add_path('/Serial', data['sse'])
self._dbusservice.add_path('/HardwareVersion', hardwareVersion)
self._dbusservice.add_path('/Connected', 1)
self._dbusservice.add_path('/UpdateIndex', 0)
# add paths without units
for path in paths_wo_unit:
self._dbusservice.add_path(path, None)
# add path values to dbus
for path, settings in self._paths.items():
self._dbusservice.add_path(
path, settings['initial'], gettextcallback=settings['textformat'], writeable=True, onchangecallback=self._handlechangedvalue)
# last update
self._lastUpdate = 0
# charging time in float
self._chargingTime = 0.0
# add _update function 'timer'
gobject.timeout_add(250, self._update) # pause 250ms before the next request
# add _signOfLife 'timer' to get feedback in log every 5minutes
gobject.timeout_add(self._getSignOfLifeInterval()*60*1000, self._signOfLife)
def _getConfig(self):
config = configparser.ConfigParser()
config.read("%s/config.ini" % (os.path.dirname(os.path.realpath(__file__))))
return config
def _getSignOfLifeInterval(self):
config = self._getConfig()
value = config['DEFAULT']['SignOfLifeLog']
if not value:
value = 0
return int(value)
def _getGoeChargerStatusUrl(self):
config = self._getConfig()
accessType = config['DEFAULT']['AccessType']
if accessType == 'OnPremise':
URL = "http://%s/status" % (config['ONPREMISE']['Host'])
else:
raise ValueError("AccessType %s is not supported" % (config['DEFAULT']['AccessType']))
return URL
def _getGoeChargerMqttPayloadUrl(self, parameter, value):
config = self._getConfig()
accessType = config['DEFAULT']['AccessType']
if accessType == 'OnPremise':
URL = "http://%s/mqtt?payload=%s=%s" % (config['ONPREMISE']['Host'], parameter, value)
else:
raise ValueError("AccessType %s is not supported" % (config['DEFAULT']['AccessType']))
return URL
def _setGoeChargerValue(self, parameter, value):
URL = self._getGoeChargerMqttPayloadUrl(parameter, str(value))
request_data = requests.get(url = URL)
# check for response
if not request_data:
raise ConnectionError("No response from go-eCharger - %s" % (URL))
json_data = request_data.json()
# check for Json
if not json_data:
raise ValueError("Converting response to JSON failed")
if json_data[parameter] == str(value):
return True
else:
logging.warning("go-eCharger parameter %s not set to %s" % (parameter, str(value)))
return False
def _getGoeChargerData(self):
URL = self._getGoeChargerStatusUrl()
try:
request_data = requests.get(url = URL, timeout=5)
except Exception:
return None
# check for response
if not request_data:
raise ConnectionError("No response from go-eCharger - %s" % (URL))
json_data = request_data.json()
# check for Json
if not json_data:
raise ValueError("Converting response to JSON failed")
return json_data
def _signOfLife(self):
logging.info("--- Start: sign of life ---")
logging.info("Last _update() call: %s" % (self._lastUpdate))
logging.info("Last '/Ac/Power': %s" % (self._dbusservice['/Ac/Power']))
logging.info("--- End: sign of life ---")
return True
def _update(self):
try:
#get data from go-eCharger
data = self._getGoeChargerData()
if data is not None:
#send data to DBus
self._dbusservice['/Ac/L1/Power'] = int(data['nrg'][7] * 0.1 * 1000)
self._dbusservice['/Ac/L2/Power'] = int(data['nrg'][8] * 0.1 * 1000)
self._dbusservice['/Ac/L3/Power'] = int(data['nrg'][9] * 0.1 * 1000)
self._dbusservice['/Ac/Power'] = int(data['nrg'][11] * 0.01 * 1000)
self._dbusservice['/Ac/Voltage'] = int(data['nrg'][0])
self._dbusservice['/Current'] = max(data['nrg'][4] * 0.1, data['nrg'][5] * 0.1, data['nrg'][6] * 0.1)
self._dbusservice['/Ac/Energy/Forward'] = int(float(data['eto']) / 10.0)
self._dbusservice['/StartStop'] = int(data['alw'])
self._dbusservice['/SetCurrent'] = int(data['amp'])
self._dbusservice['/MaxCurrent'] = int(data['ama'])
# update chargingTime, increment charge time only on active charging (2), reset when no car connected (1)
timeDelta = time.time() - self._lastUpdate
if int(data['car']) == 2 and self._lastUpdate > 0: # vehicle loads
self._chargingTime += timeDelta
elif int(data['car']) == 1: # charging station ready, no vehicle
self._chargingTime = 0
self._dbusservice['/ChargingTime'] = int(self._chargingTime)
self._dbusservice['/Mode'] = 0 # Manual, no control
config = self._getConfig()
hardwareVersion = int(config['DEFAULT']['HardwareVersion'])
if hardwareVersion == 3:
self._dbusservice['/MCU/Temperature'] = int(data['tma'][0])
else:
self._dbusservice['/MCU/Temperature'] = int(data['tmp'])
# value 'car' 1: charging station ready, no vehicle 2: vehicle loads 3: Waiting for vehicle 4: Charge finished, vehicle still connected
status = 0
if int(data['car']) == 1:
status = 0
elif int(data['car']) == 2:
status = 2
elif int(data['car']) == 3:
status = 6
elif int(data['car']) == 4:
status = 3
self._dbusservice['/Status'] = status
#logging
logging.debug("Wallbox Consumption (/Ac/Power): %s" % (self._dbusservice['/Ac/Power']))
logging.debug("Wallbox Forward (/Ac/Energy/Forward): %s" % (self._dbusservice['/Ac/Energy/Forward']))
logging.debug("---")
# increment UpdateIndex - to show that new data is available
index = self._dbusservice['/UpdateIndex'] + 1 # increment index
if index > 255: # maximum value of the index
index = 0 # overflow from 255 to 0
self._dbusservice['/UpdateIndex'] = index
#update lastupdate vars
self._lastUpdate = time.time()
else:
logging.debug("Wallbox is not available")
except Exception as e:
logging.critical('Error at %s', '_update', exc_info=e)
# return true, otherwise add_timeout will be removed from GObject - see docs http://library.isr.ist.utl.pt/docs/pygtk2reference/gobject-functions.html#function-gobject--timeout-add
return True
def _handlechangedvalue(self, path, value):
logging.info("someone else updated %s to %s" % (path, value))
if path == '/SetCurrent':
return self._setGoeChargerValue('amp', value)
elif path == '/StartStop':
return self._setGoeChargerValue('alw', value)
elif path == '/MaxCurrent':
return self._setGoeChargerValue('ama', value)
else:
logging.info("mapping for evcharger path %s does not exist" % (path))
return False
def main():
#configure logging
logging.basicConfig( format='%(asctime)s,%(msecs)d %(name)s %(levelname)s %(message)s',
datefmt='%Y-%m-%d %H:%M:%S',
level=logging.INFO,
handlers=[
logging.FileHandler("%s/current.log" % (os.path.dirname(os.path.realpath(__file__)))),
logging.StreamHandler()
])
try:
logging.info("Start")
from dbus.mainloop.glib import DBusGMainLoop
# Have a mainloop, so we can send/receive asynchronous calls to and from dbus
DBusGMainLoop(set_as_default=True)
#formatting
_kwh = lambda p, v: (str(round(v, 2)) + 'kWh')
_a = lambda p, v: (str(round(v, 1)) + 'A')
_w = lambda p, v: (str(round(v, 1)) + 'W')
_v = lambda p, v: (str(round(v, 1)) + 'V')
_degC = lambda p, v: (str(v) + '°C')
_s = lambda p, v: (str(v) + 's')
#start our main-service
pvac_output = DbusGoeChargerService(
servicename='com.victronenergy.evcharger',
paths={
'/Ac/Power': {'initial': 0, 'textformat': _w},
'/Ac/L1/Power': {'initial': 0, 'textformat': _w},
'/Ac/L2/Power': {'initial': 0, 'textformat': _w},
'/Ac/L3/Power': {'initial': 0, 'textformat': _w},
'/Ac/Energy/Forward': {'initial': 0, 'textformat': _kwh},
'/ChargingTime': {'initial': 0, 'textformat': _s},
'/Ac/Voltage': {'initial': 0, 'textformat': _v},
'/Current': {'initial': 0, 'textformat': _a},
'/SetCurrent': {'initial': 0, 'textformat': _a},
'/MaxCurrent': {'initial': 0, 'textformat': _a},
'/MCU/Temperature': {'initial': 0, 'textformat': _degC},
'/StartStop': {'initial': 0, 'textformat': lambda p, v: (str(v))}
}
)
logging.info('Connected to dbus, and switching over to gobject.MainLoop() (= event based)')
mainloop = gobject.MainLoop()
mainloop.run()
except Exception as e:
logging.critical('Error at %s', 'main', exc_info=e)
if __name__ == "__main__":