The following overview describes how to setup Modbus master communication. The overview reflects a typical programming workflow and is broken down into the sections provided below:
1.:ref:`modbus_api_port_initialization` - Initialization of Modbus controller interface for the selected port.
2.:ref:`modbus_api_master_configure_descriptor` - Configure data descriptors to access slave parameters.
The architectural approach of ESP_Modbus includes one level above standard Modbus IO driver. The additional layer is called Modbus controller and its goal is to add an abstraction such as CID - characteristic identifier. The CID is linked to a corresponding Modbus registers through the table called Data Dictionary and represents device physical parameter (such as temperature, humidity, etc.) in specific Modbus slave device. This approach allows the upper layer (e.g., MESH or MQTT) to be isolated from Modbus specifics thus simplify Modbus integration with other protocols/networks.
The Data Dictionary is the list in the Modbus master which shall be defined by user to link each CID to its corresponding Modbus registers representation using Register Mapping table of the Modbus slave being used.
Each element in this data dictionary is of type :cpp:type:`mb_parameter_descriptor_t` and represents the description of one physical characteristic:
..list-table:: Table 1 Modbus master Data Dictionary description
:widths:8 10 82
:header-rows:1
* - Field
- Description
- Detailed information
* - ``cid``
- Characteristic ID
- The identifier of characteristic (must be unique).
* - ``param_key``
- Characteristic Name
- String description of the characteristic.
* - ``param_units``
- Characteristic Units
- Physical Units of the characteristic.
* - ``mb_slave_addr``
- Modbus Slave Address
- The short address of the device with correspond parameter UID.
* - ``mb_param_type``
- Modbus Register Type
- Type of Modbus register area.
:cpp:enumerator:`MB_PARAM_INPUT`, :cpp:enumerator:`MB_PARAM_HOLDING`, :cpp:enumerator:`MB_PARAM_COIL`, :cpp:enumerator:`MB_PARAM_DISCRETE` - represents Input , Holding, Coil and Discrete input register area accordingly;
* - ``mb_reg_start``
- Modbus Register Start
- Relative register address of the characteristic in the register area.
- The storage size of the characteristic (in bytes) describes the size of data to keep into data instance during mapping. For the :ref:`modbus_mapping_complex_data_types` this allows to define the data container of the corresponded type.
..note:: The ``cid`` and ``param_key`` have to be unique. Please use the prefix to the parameter key if you have several similar parameters in your register map table.
..list-table:: Table 2 Example Register mapping table of Modbus slave
:widths:5 5 2 10 5 5 68
:header-rows:1
* - CID
- Register
- Length
- Range
- Type
- Units
- Description
* - 0
- 30000
- 4
- MAX_UINT
- U32
- Not defined
- Serial number of device (4 bytes) read-only
* - 1
- 30002
- 2
- MAX_UINT
- U16
- Not defined
- Software version (4 bytes) read-only
* - 2
- 40000
- 4
- -20..40
- FLOAT
- DegC
- Room temperature in DegC. Writing a temperature value to this register for single point calibration.
* - 3
- 40002
- 16
- 1..100 bytes
- ASCII or binary array
- Not defined
- Device name (16 bytes) ASCII string. The type of `PARAM_TYPE_ASCII` allows to read/write complex parameter (string or binary data) that corresponds to one CID.
The example above describes the definition of just several extended types. The types described in the :ref:`modbus_mapping_complex_data_types` allow to address the most useful value formats from devices of known third-party vendors.
Once the type of characteristic is defined in data dictionary the stack is responsible for conversion of values to/from the corresponding type option into the format recognizable by compiler.
..note:: Please refer to your vendor device manual and its mapping table to select the types suitable for your device.
The Modbus stack contains also the :ref:`modbus_api_endianness_conversion` - endianness conversion API functions that allow to convert values from/to each extended type into compiler representation.
During initialization of the Modbus stack, a pointer to the Data Dictionary (called descriptor) must be provided as the parameter of the function below.
:cpp:func:`mbc_master_set_descriptor`:
Initialization of master descriptor. The descriptor represents an array of type :cpp:type:`mb_parameter_descriptor_t` and describes all the characteristics accessed by master.
..code::c
staticvoid*master_handle=NULL;// Must exist in the module and be initialized prior to call
....
// Set master data dictionary for initialized master instance - master_handle
The Data Dictionary can be initialized from SD card, MQTT or other source before start of stack. Once the initialization and setup is done, the Modbus controller allows the reading of complex parameters from any slave included in descriptor table using its CID.
The Data Dictionary and related API functions (:cpp:func:`mbc_master_get_parameter`, :cpp:func:`mbc_master_set_parameter`) support custom commands to be defined for read and write operations separately. In this case, the first two options (``param_opts.cust_cmd_read`` and ``param_opts.cust_cmd_write``) are treated as read/write Modbus commands accordingly if the :cpp:enumerator:`PAR_PERMS_CUST_CMD` flag is set in the ``access`` field for the characteristic.
..note:: Please make sure that the requred commands are configured correctly in Modbus master and slave before using this feature. Refer to :ref:`modbus_api_master_handler_customization` for more information.
The Master object contains the command handling table to define specific handling functionality for each supported Modbus command. The default handling functions in this table support the most common Modbus commands. However, the list of commands can be extended by adding a new command into the handling table with its custom handling behavior. It is also possible to override the function handler for a specific command. The below described API functions allow using this behavior for Master objects.
:cpp:func:`mbc_set_handler`
The function adds new handler for the function or overrides the existing handler for the function.
:cpp:func:`mbc_get_handler`
The function returns the handler for the specified function code from handling table. Allows to keep and use the predefined handlers for standard functions.
:cpp:func:`mbc_delete_handler`
The function allows to delete the handler for specified command and free the handler table entry for this.
:cpp:func:`mbc_get_handler_count`
The function returns the actual number of command handlers registered for the object reffered by parameter.
The example code to override the handler routine for the command `<0x04 - Read Input Registers>` is below. This example allows to perform a custom action and then calls the standard handler, which maps the device data to the command buffer from the actual parameter. This is just recommended behavior for handling functions, but users can change the order of the calls if absolutely required. Please refer to the existing handler :cpp:func:`mbm_fn_read_inp_reg` for more information.
..code::c
staticvoid*master_handle=NULL;// Pointer to allocated interface structure
constuint8_toverride_command=0x04;
mb_fn_handler_fppstandard_handler=NULL;
....
// This is the custom function handler for the command.
// The handler is executed from the context of modbus controller event task and should be as simple as possible.
// Parameters: frame_ptr - the pointer to the incoming ADU frame from slave starting from function code,
// plen - the pointer to length of the frame. After return from the handler the modbus object will
// handle the end of transaction according to the exception returned.
"could not override handler, returned (0x%x).",(int)err);
..note:: The custom handler set by the function :cpp:func:`mbc_set_handler` should be as short as possible and should contain simple and safe logic to not break the normal functionality of the stack. This is user application responsibility to handle the command appropriately.
The example code to handle custom vendor specific command is below. This example sends the 'Master' string to slave and gets the response from slave with the string being appended from slave. It is just a simple echo example to demonstrate the approach.
..code::c
#define MB_CUST_DATA_LEN 100
staticcharmy_custom_data[MB_CUST_DATA_LEN]={0};// custom data buffer for the request
staticvoid*master_handle=NULL;// Pointer to allocated interface structure
// This is the custom function handler to process incoming slave response.
// Parameters: frame_ptr: is a pointer to incoming frame buffer, plen: is pointer to length including the function code
// In spite of logging showed here, try to use just simple functionality in the handler.
The list of functions below are used by the Modbus master stack from a user's application:
:cpp:func:`mbc_master_send_request`:
This function executes a blocking Modbus request. The master sends a data request (as defined in parameter request structure :cpp:type:`mb_param_request_t`) and then blocks until a response from corresponding slave and returns the status of command execution. This function provides a standard way for read/write access to Modbus devices in the network.
..note:: The function can be used to form the custom request with non-standard commands to resolve compatibility issues with the custom slaves. If it is not the case the regular API should be used: :cpp:func:`mbc_master_set_parameter`, :cpp:func:`mbc_master_get_parameter`.
:cpp:func:`mbc_master_get_cid_info`:
The function gets information about each characteristic supported in the data dictionary and returns the characteristic's description in the form of the :cpp:type:`mb_parameter_descriptor_t` structure. Each characteristic is accessed using its CID.
:cpp:func:`mbc_master_get_parameter`
The function reads the data of a characteristic defined in the parameters of a Modbus slave device. The additional data for request is taken from parameter description table.
:cpp:func:`mbc_master_get_parameter_with`
The function allows to read the data of a characteristic from any slave device addressed by `uid` parameter of the function instead of slave address defined in the data dictionary. In this case the ``mb_slave_addr`` field of the parameter descriptor :cpp:type:`mb_parameter_descriptor_t` shall be equal to ``MB_SLAVE_ADDR_PLACEHOLDER``. In case of TCP type of communication the connection phase should be completed prior call of this function.
ESP_LOGE(TAG,"Could not get information for characteristic %d.",cid);
}
:cpp:func:`mbc_master_set_parameter`
The function writes characteristic's value defined as `cid` parameter in corresponded slave device. The additional data for parameter request is taken from master parameter description table.
:cpp:func:`mbc_master_set_parameter_with`
The function is similar to previous function but allows to set the data of a characteristic in any slave device addressed by `uid` parameter of the function instead of the slave address ``mb_slave_addr`` field defined in the data dictionary. The corresponded ``mb_slave_addr`` field for the characteristic in the object disctionary shall be defined as ``MB_SLAVE_ADDR_PLACEHOLDER``.
..note:: When the TCP mode of communication is used the functions above additionally check the connection state of the slave being accessed and return error if the slave connection is not actual.
ESP_LOGE(TAG,"Set data fail, err = 0x%x (%s).",(int)err,(char*)esp_err_to_name(err));
}
The master supports the <0x11 - Report Slave ID> Modbus command to read vendor specific information from the slave. It uses the :cpp:func:`mbc_master_send_request` function to send request.
The example to retrieve the slave identificator from slave:
..code::c
#define MB_DEVICE_ADDR1 1 // the slave UID to retrieve information
...
staticvoid*master_handle=NULL;// the master handler is initialized previously
...
// Set the request stucture for the master to send the <Report Slave ID> command
mb_param_request_treq={
.slave_addr=MB_DEVICE_ADDR1,// the UID of the device to get the information,
.command=0x11,// the <Report Slave ID> command,
.reg_start=0,// is obsolete, need to be zero for this request,
.reg_size=(CONFIG_FMB_CONTROLLER_SLAVE_ID_MAX_SIZE>>1)// size of the buffer in registers to save ID