add custom commands into master data dict v2

This commit is contained in:
aleks authored and Alex Lisitsyn committed 2025-06-09 08:02:24 +01:00
1 parent ba2b683d6d
commit 38205ca78f
7 files changed
+97 -101

No files matched your search

@@ -45,6 +45,36 @@ extern "C" {
#define MB_EACH_ELEM(psrc, pdest, arr_size, elem_size) \
(int i = 0; (i < (arr_size / elem_size)); i++, pdest += elem_size, psrc += elem_size)
/**
* @brief Request mode for parameter to use in data dictionary
*/
typedef enum {
MB_PARAM_READ, /*!< Read parameter values. */
MB_PARAM_WRITE /*!< Write parameter values. */
} mb_param_mode_t;
/*!
* \brief Modbus parameter options for description table
*/
typedef union {
struct {
int opt1; /*!< Parameter option1 */
int opt2; /*!< Parameter option2 */
int opt3; /*!< Parameter option3 */
};
struct {
int min; /*!< Parameter minimum value */
int max; /*!< Parameter maximum value */
int step; /*!< Step of parameter change tracking */
};
struct {
int cust_cmd_read; /*!< Parameter custom read request command */
int cust_cmd_write; /*!< Parameter custom write request command */
int cust_cmd_not_used; /*!< Not used option for custom request */
};
} mb_parameter_opt_t;
/*!
* \brief Modbus descriptor table parameter type defines.
*/
@@ -109,23 +139,6 @@ typedef enum {
PARAM_MAX_SIZE
} mb_descr_size_t;
/*!
* \brief Modbus parameter options for description table (associated with the characteristic).
* and can be used in user application to process data.
*/
typedef union {
struct {
int opt1; /*!< Parameter option1 */
int opt2; /*!< Parameter option2 */
int opt3; /*!< Parameter option3 */
}; /*!< Parameter options version 1 */
struct {
int min; /*!< Parameter minimum value */
int max; /*!< Parameter maximum value */
int step; /*!< Step of parameter change tracking */
}; /*!< Parameter options version 2 */
} mb_parameter_opt_t;
/**
* @brief Permissions for the characteristics
*/
@@ -133,12 +146,15 @@ typedef enum {
PAR_PERMS_READ = 1 << BIT0, /**< the characteristic of the device are readable */
PAR_PERMS_WRITE = 1 << BIT1, /**< the characteristic of the device are writable*/
PAR_PERMS_TRIGGER = 1 << BIT2, /**< the characteristic of the device are triggerable */
PAR_PERMS_CUST_CMD = 1 << BIT3, /**< the characteristic uses custom commands */
PAR_PERMS_READ_WRITE = PAR_PERMS_READ | PAR_PERMS_WRITE, /**< the characteristic of the device are readable & writable */
PAR_PERMS_READ_TRIGGER = PAR_PERMS_READ | PAR_PERMS_TRIGGER, /**< the characteristic of the device are readable & triggerable */
PAR_PERMS_WRITE_TRIGGER = PAR_PERMS_WRITE | PAR_PERMS_TRIGGER, /**< the characteristic of the device are writable & triggerable */
PAR_PERMS_READ_WRITE_TRIGGER = PAR_PERMS_READ_WRITE | PAR_PERMS_TRIGGER, /**< the characteristic of the device are readable & writable & triggerable */
PAR_PERMS_READ_WRITE_CUST_CMD = PAR_PERMS_READ_WRITE | PAR_PERMS_CUST_CMD /**< the characteristic supports custom read/write commands */
} mb_param_perms_t;
/**
* @brief Characteristics descriptor type is used to describe characteristic and
* link it with Modbus parameters that reflect its data.