/* * FreeModbus Libary: A portable Modbus implementation for Modbus ASCII/RTU. * Copyright (c) 2016, 2017 Nucleron R&D LLC * Copyright (c) 2006 Christian Walter * All rights reserved. * * Redistribution and use in source and binary forms, with or without * modification, are permitted provided that the following conditions * are met: * 1. Redistributions of source code must retain the above copyright * notice, this list of conditions and the following disclaimer. * 2. Redistributions in binary form must reproduce the above copyright * notice, this list of conditions and the following disclaimer in the * documentation and/or other materials provided with the distribution. * 3. The name of the author may not be used to endorse or promote products * derived from this software without specific prior written permission. * * THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR * IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES * OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. * IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT, * INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT * NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, * DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY * THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT * (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF * THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. * * File: $Id: mbfuncholding.c, v 1.12 2007/02/18 23:48:22 wolti Exp $ */ #include #include #include "mb_slave.h" /* ----------------------- Defines ------------------------------------------*/ #define MB_PDU_FUNC_READ_ADDR_OFF (MB_PDU_DATA_OFF + 0) #define MB_PDU_FUNC_READ_REGCNT_OFF (MB_PDU_DATA_OFF + 2) #define MB_PDU_FUNC_READ_SIZE (4) #define MB_PDU_FUNC_READ_REGCNT_MAX (0x007D) #define MB_PDU_FUNC_WRITE_ADDR_OFF (MB_PDU_DATA_OFF + 0) #define MB_PDU_FUNC_WRITE_VALUE_OFF (MB_PDU_DATA_OFF + 2) #define MB_PDU_FUNC_WRITE_SIZE (4) #define MB_PDU_FUNC_WRITE_MUL_ADDR_OFF (MB_PDU_DATA_OFF + 0) #define MB_PDU_FUNC_WRITE_MUL_REGCNT_OFF (MB_PDU_DATA_OFF + 2) #define MB_PDU_FUNC_WRITE_MUL_BYTECNT_OFF (MB_PDU_DATA_OFF + 4) #define MB_PDU_FUNC_WRITE_MUL_VALUES_OFF (MB_PDU_DATA_OFF + 5) #define MB_PDU_FUNC_WRITE_MUL_SIZE_MIN (5) #define MB_PDU_FUNC_WRITE_MUL_REGCNT_MAX (0x0078) #define MB_PDU_FUNC_READWRITE_READ_ADDR_OFF (MB_PDU_DATA_OFF + 0) #define MB_PDU_FUNC_READWRITE_READ_REGCNT_OFF (MB_PDU_DATA_OFF + 2) #define MB_PDU_FUNC_READWRITE_WRITE_ADDR_OFF (MB_PDU_DATA_OFF + 4) #define MB_PDU_FUNC_READWRITE_WRITE_REGCNT_OFF (MB_PDU_DATA_OFF + 6) #define MB_PDU_FUNC_READWRITE_BYTECNT_OFF (MB_PDU_DATA_OFF + 8) #define MB_PDU_FUNC_READWRITE_WRITE_VALUES_OFF (MB_PDU_DATA_OFF + 9) #define MB_PDU_FUNC_READWRITE_SIZE_MIN (9) /* ----------------------- Static functions ---------------------------------*/ mb_exception_t mb_error_to_exception(mb_err_enum_t error_code); /* ----------------------- Start implementation -----------------------------*/ #if MB_FUNC_WRITE_HOLDING_ENABLED > 0 mb_exception_t mbs_fn_write_holding_reg(mb_base_t *inst, uint8_t *frame_ptr, uint16_t *len_buf) { uint16_t reg_addr; mb_exception_t status = MB_EX_NONE; mb_err_enum_t reg_status = MB_EILLFUNC; if (*len_buf == (MB_PDU_FUNC_WRITE_SIZE + MB_PDU_SIZE_MIN)) { reg_addr = (uint16_t)(frame_ptr[MB_PDU_FUNC_WRITE_ADDR_OFF] << 8); reg_addr |= (uint16_t)(frame_ptr[MB_PDU_FUNC_WRITE_ADDR_OFF + 1]); reg_addr++; /* Make callback to update the value. */ if (inst->rw_cbs.reg_holding_cb) { reg_status = inst->rw_cbs.reg_holding_cb(inst, &frame_ptr[MB_PDU_FUNC_WRITE_VALUE_OFF], reg_addr, 1, MB_REG_WRITE); } /* If an error occured convert it into a Modbus exception. */ if (reg_status != MB_ENOERR) { status = mb_error_to_exception(reg_status); } } else { /* Can't be a valid request because the length is incorrect. */ status = MB_EX_ILLEGAL_DATA_VALUE; } return status; } #endif #if MB_FUNC_WRITE_MULTIPLE_HOLDING_ENABLED > 0 mb_exception_t mbs_fn_write_multi_holding_reg(mb_base_t *inst, uint8_t *frame_ptr, uint16_t *len_buf) { uint16_t reg_addr; uint16_t reg_cnt; uint8_t reg_byte_cnt; mb_exception_t status = MB_EX_NONE; mb_err_enum_t reg_status = MB_EILLFUNC; if (*len_buf >= (MB_PDU_FUNC_WRITE_MUL_SIZE_MIN + MB_PDU_SIZE_MIN)) { reg_addr = (uint16_t)(frame_ptr[MB_PDU_FUNC_WRITE_MUL_ADDR_OFF] << 8); reg_addr |= (uint16_t)(frame_ptr[MB_PDU_FUNC_WRITE_MUL_ADDR_OFF + 1]); reg_addr++; reg_cnt = (uint16_t)(frame_ptr[MB_PDU_FUNC_WRITE_MUL_REGCNT_OFF] << 8); reg_cnt |= (uint16_t)(frame_ptr[MB_PDU_FUNC_WRITE_MUL_REGCNT_OFF + 1]); reg_byte_cnt = frame_ptr[MB_PDU_FUNC_WRITE_MUL_BYTECNT_OFF]; if ((reg_cnt >= 1) && (reg_cnt <= MB_PDU_FUNC_WRITE_MUL_REGCNT_MAX) && (reg_byte_cnt == (uint8_t) (2 * reg_cnt))) { /* Make callback to update the register values. */ if (inst->rw_cbs.reg_holding_cb) { reg_status = inst->rw_cbs.reg_holding_cb(inst, &frame_ptr[MB_PDU_FUNC_WRITE_MUL_VALUES_OFF], reg_addr, reg_cnt, MB_REG_WRITE); } /* If an error occured convert it into a Modbus exception. */ if (reg_status != MB_ENOERR) { status = mb_error_to_exception(reg_status); } else { /* The response contains the function code, the starting * address and the quantity of registers. We reuse the * old values in the buffer because they are still valid. */ *len_buf = MB_PDU_FUNC_WRITE_MUL_BYTECNT_OFF; } } else { status = MB_EX_ILLEGAL_DATA_VALUE; } } else { /* Can't be a valid request because the length is incorrect. */ status = MB_EX_ILLEGAL_DATA_VALUE; } return status; } #endif #if MB_FUNC_READ_HOLDING_ENABLED > 0 mb_exception_t mbs_fn_read_holding_reg(mb_base_t *inst, uint8_t *frame_ptr, uint16_t *len_buf) { uint16_t reg_addr; uint16_t reg_cnt; uint8_t *frame_cur; mb_exception_t status = MB_EX_NONE; mb_err_enum_t reg_status = MB_EILLFUNC; if (*len_buf == (MB_PDU_FUNC_READ_SIZE + MB_PDU_SIZE_MIN)) { reg_addr = (uint16_t)(frame_ptr[MB_PDU_FUNC_READ_ADDR_OFF] << 8); reg_addr |= (uint16_t)(frame_ptr[MB_PDU_FUNC_READ_ADDR_OFF + 1]); reg_addr++; reg_cnt = (uint16_t)(frame_ptr[MB_PDU_FUNC_READ_REGCNT_OFF] << 8); reg_cnt = (uint16_t)(frame_ptr[MB_PDU_FUNC_READ_REGCNT_OFF + 1]); /* Check if the number of registers to read is valid. If not * return Modbus illegal data value exception. */ if ((reg_cnt >= 1) && (reg_cnt <= MB_PDU_FUNC_READ_REGCNT_MAX)) { /* Set the current PDU data pointer to the beginning. */ frame_cur = &frame_ptr[MB_PDU_FUNC_OFF]; *len_buf = MB_PDU_FUNC_OFF; /* First byte contains the function code. */ *frame_cur++ = MB_FUNC_READ_HOLDING_REGISTER; *len_buf += 1; /* Second byte in the response contain the number of bytes. */ *frame_cur++ = (uint8_t) (reg_cnt * 2); *len_buf += 1; /* Make callback to fill the buffer. */ if (inst->rw_cbs.reg_holding_cb) { reg_status = inst->rw_cbs.reg_holding_cb(inst, frame_cur, reg_addr, reg_cnt, MB_REG_READ); } /* If an error occured convert it into a Modbus exception. */ if (reg_status != MB_ENOERR) { status = mb_error_to_exception(reg_status); } else { *len_buf += reg_cnt * 2; } } else { status = MB_EX_ILLEGAL_DATA_VALUE; } } else { /* Can't be a valid request because the length is incorrect. */ status = MB_EX_ILLEGAL_DATA_VALUE; } return status; } #endif #if MB_FUNC_READWRITE_HOLDING_ENABLED > 0 mb_exception_t mbs_fn_rw_multi_holding_reg(mb_base_t *inst, uint8_t *frame_ptr, uint16_t *len_buf) { uint16_t reg_rd_addr; uint16_t reg_rd_cnt; uint16_t reg_wr_addr; uint16_t reg_wr_cnt; uint8_t reg_wr_byte_cnt; uint8_t *frame_cur; mb_exception_t status = MB_EX_NONE; mb_err_enum_t reg_status = MB_EILLFUNC; (void)inst; if (*len_buf >= (MB_PDU_FUNC_READWRITE_SIZE_MIN + MB_PDU_SIZE_MIN)) { reg_rd_addr = (uint16_t)(frame_ptr[MB_PDU_FUNC_READWRITE_READ_ADDR_OFF] << 8U); reg_rd_addr |= (uint16_t)(frame_ptr[MB_PDU_FUNC_READWRITE_READ_ADDR_OFF + 1]); reg_rd_addr++; reg_rd_cnt = (uint16_t)(frame_ptr[MB_PDU_FUNC_READWRITE_READ_REGCNT_OFF] << 8U); reg_rd_cnt |= (uint16_t)(frame_ptr[MB_PDU_FUNC_READWRITE_READ_REGCNT_OFF + 1]); reg_wr_addr = (uint16_t)(frame_ptr[MB_PDU_FUNC_READWRITE_WRITE_ADDR_OFF] << 8U); reg_wr_addr |= (uint16_t)(frame_ptr[MB_PDU_FUNC_READWRITE_WRITE_ADDR_OFF + 1]); reg_wr_addr++; // increase by one reg_wr_cnt = (uint16_t)(frame_ptr[MB_PDU_FUNC_READWRITE_WRITE_REGCNT_OFF] << 8U); reg_wr_cnt |= (uint16_t)(frame_ptr[MB_PDU_FUNC_READWRITE_WRITE_REGCNT_OFF + 1]); reg_wr_byte_cnt = frame_ptr[MB_PDU_FUNC_READWRITE_BYTECNT_OFF]; if ((reg_rd_cnt >= 1) && (reg_rd_cnt <= MB_PDU_FUNC_READ_REGCNT_MAX) && (reg_wr_cnt >= 1) && (reg_wr_cnt <= MB_PDU_FUNC_WRITE_MUL_REGCNT_MAX) && ((2 * reg_wr_cnt) == reg_wr_byte_cnt)) { /* Make callback to update the register values. */ if (inst->rw_cbs.reg_holding_cb) { reg_status = inst->rw_cbs.reg_holding_cb(inst, &frame_ptr[MB_PDU_FUNC_READWRITE_WRITE_VALUES_OFF], reg_wr_addr, reg_wr_cnt, MB_REG_WRITE); } if (reg_status == MB_ENOERR) { /* Set the current PDU data pointer to the beginning. */ frame_cur = &frame_ptr[MB_PDU_FUNC_OFF]; *len_buf = MB_PDU_FUNC_OFF; /* First byte contains the function code. */ *frame_cur++ = MB_FUNC_READWRITE_MULTIPLE_REGISTERS; *len_buf += 1; /* Second byte in the response contain the number of bytes. */ *frame_cur++ = (uint8_t) (reg_rd_cnt * 2); *len_buf += 1; /* Make the read callback. */ if (inst->rw_cbs.reg_holding_cb) { reg_status = inst->rw_cbs.reg_holding_cb(inst, frame_cur, reg_rd_addr, reg_rd_cnt, MB_REG_READ); } if (reg_status == MB_ENOERR) { *len_buf += 2 * reg_rd_cnt; } } if (reg_status != MB_ENOERR) { status = mb_error_to_exception(reg_status); } } else { status = MB_EX_ILLEGAL_DATA_VALUE; } } return status; } #endif