* FreeModbus Libary: A portable Modbus implementation for Modbus ASCII/RTU.
* Copyright (c) 2016, 2017 Nucleron R&D LLC <main@nucleron.ru>
* Copyright (C) 2013 Armink <armink.ztl@gmail.com>
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions
* are met:
* 1. Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
* 2. Redistributions in binary form must reproduce the above copyright
* notice, this list of conditions and the following disclaimer in the
* documentation and/or other materials provided with the distribution.
* 3. The name of the author may not be used to endorse or promote products
* derived from this software without specific prior written permission.
*
* THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
* IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
* OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
* IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
* INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
* NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
* DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
* THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
* (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
* THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
*
* File: $Id: mbfuncinput_m.c, v 1.60 2013/10/12 14:23:40 Armink Add Master Functions Exp $
*/
#include "mb_common.h"
#include "mb_proto.h"
#include "transport_common.h"
#include "mb_master.h"
/* ----------------------- Defines ------------------------------------------*/
#define MB_PDU_REQ_READ_ADDR_OFF (MB_PDU_DATA_OFF + 0)
#define MB_PDU_REQ_READ_REGCNT_OFF (MB_PDU_DATA_OFF + 2)
#define MB_PDU_REQ_READ_SIZE (4)
#define MB_PDU_FUNC_READ_BYTECNT_OFF (MB_PDU_DATA_OFF + 0)
#define MB_PDU_FUNC_READ_VALUES_OFF (MB_PDU_DATA_OFF + 1)
#define MB_PDU_FUNC_READ_SIZE_MIN (1)
#define MB_PDU_FUNC_READ_RSP_BYTECNT_OFF (MB_PDU_DATA_OFF)
/* ----------------------- Static functions ---------------------------------*/
mb_exception_t mb_error_to_exception(mb_err_enum_t error_code);
/* ----------------------- Start implementation -----------------------------*/
#if MB_MASTER_RTU_ENABLED || MB_MASTER_ASCII_ENABLED || MB_MASTER_TCP_ENABLED
#if MB_FUNC_WRITE_HOLDING_ENABLED
/**
* This function will request read input register.
*
* @param snd_addr salve address
* @param reg_addr register start address
* @param reg_num register total number
* @param timeout timeout (-1 will waiting forever)
*
* @return error code
*/
mb_err_enum_t mbm_rq_read_inp_reg(mb_base_t *inst, uint8_t snd_addr, uint16_t reg_addr, uint16_t reg_num, uint32_t tout)
{
uint8_t *mb_frame_ptr;
if (!inst || (snd_addr > MB_ADDRESS_MAX)) {
return MB_EINVAL;
}
if (!mb_port_event_res_take(inst->port_obj, tout)) {
return MB_EBUSY;
}
inst->get_send_buf(inst, &mb_frame_ptr);
inst->set_dest_addr(inst, snd_addr);
mb_frame_ptr[MB_PDU_FUNC_OFF] = MB_FUNC_READ_INPUT_REGISTER;
mb_frame_ptr[MB_PDU_REQ_READ_ADDR_OFF] = reg_addr >> 8;
mb_frame_ptr[MB_PDU_REQ_READ_ADDR_OFF + 1] = reg_addr;
mb_frame_ptr[MB_PDU_REQ_READ_REGCNT_OFF] = reg_num >> 8;
mb_frame_ptr[MB_PDU_REQ_READ_REGCNT_OFF + 1] = reg_num;
inst->set_send_len(inst, MB_PDU_SIZE_MIN + MB_PDU_REQ_READ_SIZE);
(void)mb_port_event_post(inst->port_obj, EVENT(EV_FRAME_TRANSMIT | EV_TRANS_START) );
return mb_port_event_wait_req_finish(inst->port_obj);
}
mb_exception_t mbm_fn_read_inp_reg(mb_base_t *inst, uint8_t *frame_ptr, uint16_t *len_buf)
{
mb_exception_t status = MB_EX_NONE;
mb_err_enum_t reg_status = MB_EILLFUNC;
uint16_t reg_cnt;
uint16_t reg_address;
uint8_t *mb_frame_ptr;
/* If this request is broadcast, and it's read mode. This request don't need execute. */
if (inst->transp_obj->frm_is_bcast(inst->transp_obj)) {
status = MB_EX_NONE;
} else if (*len_buf >= MB_PDU_SIZE_MIN + MB_PDU_FUNC_READ_SIZE_MIN) {
inst->get_send_buf(inst, &mb_frame_ptr);
reg_address = (uint16_t)( mb_frame_ptr[MB_PDU_REQ_READ_ADDR_OFF] << 8 );
reg_address |= (uint16_t)( mb_frame_ptr[MB_PDU_REQ_READ_ADDR_OFF + 1] );
reg_address++;
reg_cnt = (uint16_t)( mb_frame_ptr[MB_PDU_REQ_READ_REGCNT_OFF] << 8 );
reg_cnt |= (uint16_t)( mb_frame_ptr[MB_PDU_REQ_READ_REGCNT_OFF + 1] );
/* Check if the number of registers to read is valid. If not
* return Modbus illegal data value exception.
*/
if ((reg_cnt >= 1) && (2 * reg_cnt == frame_ptr[MB_PDU_FUNC_READ_BYTECNT_OFF])) {
/* Make callback to fill the buffer. */
if (inst->rw_cbs.reg_input_cb) {
reg_status = inst->rw_cbs.reg_input_cb(inst, &frame_ptr[MB_PDU_FUNC_READ_VALUES_OFF], reg_address, reg_cnt);
}
/* If an error occured convert it into a Modbus exception. */
if (reg_status != MB_ENOERR) {
status = mb_error_to_exception(reg_status);
}
} else {
status = MB_EX_ILLEGAL_DATA_VALUE;
}
} else {
/* Can't be a valid request because the length is incorrect. */
status = MB_EX_ILLEGAL_DATA_VALUE;
}
return status;
}
#endif
#endif // #if MB_MASTER_RTU_ENABLED || MB_MASTER_ASCII_ENABLED || MB_MASTER_TCP_ENABLED