forked from mpusz/mp-units
Printing of uknown non-coherent units fixed
This commit is contained in:
@@ -145,12 +145,14 @@ constexpr auto unit_text()
|
||||
return U::symbol;
|
||||
}
|
||||
else {
|
||||
// print as a prefix or ratio of a reference unit
|
||||
auto prefix_txt = prefix_or_ratio_text<typename U::ratio, typename U::reference::prefix_type>();
|
||||
// print as a prefix or ratio of a coherent unit
|
||||
using coherent_unit = dimension_unit<Dim>;
|
||||
using ratio = ratio_divide<typename U::ratio, typename coherent_unit::ratio>;
|
||||
auto prefix_txt = prefix_or_ratio_text<ratio, typename U::reference::prefix_type>();
|
||||
|
||||
if constexpr(has_symbol<typename U::reference>) {
|
||||
// use predefined reference unit symbol
|
||||
return prefix_txt + U::reference::symbol;
|
||||
if constexpr(has_symbol<coherent_unit>) {
|
||||
// use predefined coherent unit symbol
|
||||
return prefix_txt + coherent_unit::symbol;
|
||||
}
|
||||
else {
|
||||
// use derived dimension ingredients to create a unit symbol
|
||||
|
||||
Reference in New Issue