docs: various small documentation fixes

This commit is contained in:
Mateusz Pusz
2020-09-14 08:45:36 +02:00
parent 452f1a105d
commit 8cc7a53943
8 changed files with 66 additions and 62 deletions
+4 -3
View File
@@ -7,9 +7,10 @@ A :term:`quantity` is a concrete amount of a unit for a specified dimension
with a specific representation and is represented in the library with a
`quantity` class template.
.. _quantity-construction:
Quantity Construction
---------------------
Construction
------------
To create the quantity object from a :term:`scalable number` we just have to pass
the value to the `quantity` class template explicit constructor::
@@ -189,7 +190,7 @@ are provided::
There are two special units provided for usage with such a quantity:
- `one` which is the :ref:`coherent unit` of dimensionless quantity and does not
- `one` which is the :term:`coherent derived unit` of dimensionless quantity and does not
provide any textual symbol (according to the ISO definition "the measurement units and
values of quantities of dimension one are numbers"),
- `percent` which has the symbol ``%`` and ``ratio(1, 100)`` of the `one` unit.
+5 -3
View File
@@ -3,13 +3,15 @@
Quantity Points
===============
A `quantity point` is an absolute quantity with respect to zero
A quantity point is an absolute quantity with respect to zero
(which represents some origin) and is represented in the library with a
`quantity_point` class template.
Quantity Point Construction
---------------------------
.. _quantity-point-construction:
Construction
------------
To create the quantity point object from a `quantity` we just have to pass
the value to the `quantity_point` class template explicit constructor::
+15 -15
View File
@@ -24,7 +24,7 @@ Base Units
``m`` (meter) is a base unit of length, ``s`` (second) is a base unit of
time. In each :term:`coherent system of units`, there is only one base
unit for each base quantity. This is why a base unit type is required by
the `base_dimension` definition in this library. For example `si::dim_length`
the `base_dimension` definition in this library. For example ``si::dim_length``
can be defined in the following way::
namespace si {
@@ -33,7 +33,7 @@ can be defined in the following way::
}
where `si::metre` is defined as::
where ``si::metre`` is defined as::
namespace si {
@@ -43,8 +43,8 @@ where `si::metre` is defined as::
In the above definition ``"m"`` is the unit symbol to be used in the text
output, and ``si::prefix`` specifies that the library should allow
definitions of prefixed units using `si::metre` as a reference (i.e.
`si::centimetre`).
definitions of prefixed units using ``si::metre`` as a reference (i.e.
``si::centimetre``).
.. seealso::
@@ -81,10 +81,10 @@ The fact that both base dimensions use the same identifier ``"L"`` tells
the library that both definitions refer to the same physical dimension of
length. The only difference is the measurement unit used to define their
base dimensions. Thanks to using the unit that is defined in terms of the
the same reference unit as the one provided to `si::dim_length` definition
(namely `si::centimetre` which is ``1/100`` of `si::metre`) we also enabled
the same reference unit as the one provided to ``si::dim_length`` definition
(namely ``si::centimetre`` which is ``1/100`` of ``si::metre``) we also enabled
the ability to easily convert between those 2 base dimensions (as the library
knows how to convert `si::metre` to `si::centimetre` and vice versa).
knows how to convert ``si::metre`` to ``si::centimetre`` and vice versa).
.. seealso::
@@ -145,7 +145,7 @@ where ``kilogram_metre_per_second`` is defined as::
struct kilogram_metre_per_second : unit<kilogram_metre_per_second> {};
However, the easiest way to define momentum is just to use the
`si::speed` derived dimension in the recipe:
``si::speed`` derived dimension in the recipe:
.. code-block::
:emphasize-lines: 3
@@ -217,8 +217,8 @@ and define units like::
Finally, the last of the `named_scaled_unit` class template parameters
provide a reference unit for scaling. Please note that it can be a dimension's
base/coherent unit (like `si::second`) or any other unit (i.e. `si::minute`,
`si::hour`) that is a scaled version of the dimension's base/coherent unit.
base/coherent unit (like ``si::second``) or any other unit (i.e. ``si::minute``,
``si::hour``) that is a scaled version of the dimension's base/coherent unit.
Prefixed Unit
@@ -272,7 +272,7 @@ domain::
}
With the definitions like above we can easily define prefixed unit. For
example we can define `si::kilometre` as::
example we can define ``si::kilometre`` as::
namespace si {
@@ -303,7 +303,7 @@ ratio in reference to "metre per second":
Whichever, we choose there will always be someone not happy with our choice.
Thanks to a `deduced_unit` class template provided by the library this problem
does not exist at all. With it `si::kilometre_per_hour` can be defined as::
does not exist at all. With it ``si::kilometre_per_hour`` can be defined as::
namespace si {
@@ -392,12 +392,12 @@ unknown/undefined unit type like in the below example::
Length auto l = 100_q_km_per_h * 10_q_s;
The type of ``l`` above will be
:expr:`si::length<scaled_unit<ratio(1, 36, 1), si::metre>, long double>`. This is caused
``si::length<scaled_unit<ratio(1, 36, 1), si::metre>, long double>``. This is caused
by the fact that the library does not define a unit of a length quantity that has the
ratio ``10/36`` of a `si::metre`. If such a unit was predefined we would see its concrete
ratio ``10/36`` of a ``si::metre``. If such a unit was predefined we would see its concrete
type here instead.
.. seealso::
To learn more about unknown units please refer to
:ref:`Working with Unknown Units and Dimensions` chapter.