We don't need to use tini.
We don't have anything in the rook operator that would
either create zombie processes (no threads) or use
exec (to fork). The Go binary has a really good
signal handling mechanism.
Closes: https://github.com/rook/rook/issues/8794
Signed-off-by: Sébastien Han <seb@redhat.com>
The flex driver has been fully deprecated and thus removed from Rook.
Before upgrading to v1.8, users will need to convert existing flex volumes
from flex to csi volumes.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
This commit is a large refactor on how the operator starts, stops and
how it starts various sub-components such as the ceph-csi driver. It
also refines the way we cancel orchestrations. We don't use breakpoints
anymore but send our self a SIGUP to reload our controller runtime
manager.
The reload will happen under different circonstances like:
* a new adminission controller secret is created/deleted/changed
* a CephCluster CR is edited
As mentioned earlier, the csi driver now has its own controller, just
like flex. It reacts to change in the operator config map for particular
ROOK_CSI_ fields.
A second new controller for the operator's general config has been
created, it manages:
* the logging level
* the ceph CLI command timeout
* the discovery daemon
The operator reacts much more rapidly to cancellation events by stopping
the manager's context and reloading it.
Signed-off-by: Sébastien Han <seb@redhat.com>
We don't need to use github.com/ghodss/yaml since
"k8s.io/apimachinery/pkg/util/yaml" provides the same functionality and
we already import it.
Signed-off-by: Sébastien Han <seb@redhat.com>
During disaster recovery/migration of a cluster, as part of the failover, the
kubernetes artifacts like deployment, PVC, PV, etc will be restored to a new
cluster by the admin. Even if the kubernetes objects are restored the
corresponding RBD/CephFS subvolume cannot be retrieved during CSI operations as
the clusterID and poolID are not the same in both clusters
This PR creates a mapping between Cluster ID and RBD Pool ID between
local cluster and peer cluster.
Signed-off-by: Santosh Pillai <sapillai@redhat.com>
If we call OwnerInfo.SetOwnerReference for an object multiple times,
it results in OwnerReference duplication.
Signed-off-by: Yuzuki Mimura <yuzuki725.m@gmail.com>
Co-authored-by: Hiroya Onoe <onoehiroya@gmail.com>
This commit update the PodDisruptionBudget policy to use version v1
Updated to policy/v1 as policy/v1beta1 PodDisruptionBudget is deprecated in v1.21+
Closes: https://github.com/rook/rook/issues/7917
Signed-off-by: parth-gr <paarora@redhat.com>
The info log is rather verbose with all the filtering of the K8s version
like the following:
returning version v1.19.0 instead of v1.19.0+43983cd
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
In pkg/operator/k8sutil/network.go:ApplyMultus(), sort the string
annotations before applying them so that Rook will avoid the situation
where a Deployment or Pod will need updated repeatedly even when no
Multus network configuration has changed.
Signed-off-by: Blaine Gardner <blaine.gardner@redhat.com>
This commit removes obsolete statefulset create, delete,
addlabel, templateToStatefulset functions which were part of
deprecated csi support for k8s 1.13 and should have been
removed as part of https://github.com/rook/rook/pull/5982.
It also adds Unit test for templateToDeployment func.
Signed-off-by: Rakshith R <rar@redhat.com>
Expand the functionality of 'ExpandPVCIfRequired' to check if
storageclass does allow expansion then only expand the PVC.
otherwise skip the expansion.
Signed-off-by: Nitin Goyal <nigoyal@redhat.com>
If the monitors addresses change, we must update the peer secret with
the new addresses. For this, each time the configmap
"rook-ceph-mon-endpoints" is updated, we trigger a reconcile on the
CephBlockPool CRs, which will update the token secret.
Signed-off-by: Sébastien Han <seb@redhat.com>
The rook.io/v1 package was only an internal implementation detail and
does not have any CRDs that rely on it. The CRD deserialization should
handle the change in internal types without any issue. This separation
gives more flexibility for the storage providers to implement exactly
what is needed for their storage provider instead of forcing to use the
same types and risk affecting another storage provider.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
With this change, the Rook ceph cluster can have only a public network or
only a cluster network or both can be specified. Prior to this commit if
only a public network was specified, it was copied to the cluster network.
Signed-off-by: rohan47 <rohgupta@redhat.com>
Events like node drain can take more than 10-15 minutes. If the node is not update the default monTimeOut of 10 minutes, then rook will attempt to fail over the mon. This failover won't work as the node is still down.
This PR retries once before the mon failover if the mon pod is not scheduled
Signed-off-by: Santosh Pillai <sapillai@redhat.com>
Update OSDs in parallel per the design in
design/ceph/update-osds-in-parallel.md
The max number of OSDs updated in parallel is currently fixed at 20.
Signed-off-by: Blaine Gardner <blaine.gardner@redhat.com>
In the case of PVC,
We are giving lower priority to all placement.
We want deviceSet placement to applied and
override in case of overlapping settings and
we are merging nodeAffinity if applied in both
all placement and deviceSet.
In case of non-PVC,
we apply spec.placement
Signed-off-by: subhamkrai <srai@redhat.com>
Co-authored-by: Travis Nielsen <tnielsen@redhat.com>
It's better to validate ownerReferences when setting them. In addition, we should use
controllerrutil.Set{Controller,Owner}Reference, that have such validation, as possible.
Signed-off-by: Satoru Takeuchi <satoru.takeuchi@gmail.com>
If there are multiple mgrs running, the operator will automatically
add pod antiaffinity across hosts by default. For stretch clusters,
antiaffinity across the stretch failure domain (e.g. zones)
will be added. Required antiaffinity will be created unless the
test setting allowMultiplePerNode is set to true.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
If there are two mgr daemons, they should be running on different
hosts or zones, depending on the failure domain.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
The mgr daemon may be failed over by ceph if the active mgr is not
responding and the standby mgr is available. If the active mgr changes
the services for the dashboard and metrics will be updated with a
label selector for the new active mgr. The services cannot direct
traffic to the standby mgr or else they will be incorrectly redirected
to the active mgr.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
Do not reconcile ServiceMonitor/PrometheusRule on label updates.
This allows users to add custom labels which can be used by
custom Prometheus instances for monitoring.
Signed-off-by: Umanga Chapagain <chapagainumanga@gmail.com>
Remove features and design that supports adding OSDs to Ceph clusters
via `spec:driveGroups`. Update the Ceph upgrade doc that informs users
who currently use Drive Groups (we believe there are none of these
users) how to migrate to using the `spec:storage` config.
Resolves https://github.com/rook/rook/issues/7275
Revert "ceph: fix drive group deployment failure"
This reverts commit 76f1d9944e.
Revert "ceph: osd: add drive groups spec to cluster CR"
This reverts commit 7117fc12b7.
Revert "design: ceph orchestrator module add/remove OSDs"
This reverts commit 178187d035.
Signed-off-by: Blaine Gardner <blaine.gardner@redhat.com>
The osd prepare job detects the failure domain for the OSD by querying
the node topology labels. This topology is then assigned to the OSD
daemon in the CRUSH map. Previously, the affinity was required to be
set in the cluster CR, but it was very difficult to get right. Now the
operator will enforce the correct topology label on the OSD daemon
nodeAffinity by setting the label of the lowest topology in the hierarcy.
For example, if there are region, zone, and rack labels, the rack label
would be used to set the node affinity for the OSD daemon. If an
OSD prepare job is run in rack1, the corresponding OSD daemon will
have node affinity to rack1 to ensure the same topology. Previously,
the OSD could have ended up in rack2 unless the storageClassDeviceSet
placement was very carefully crafted.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
we don't want to merge the node affinity if specified in both
storageClassDeviceSet and placement. Now, we are passing new
boolean argument in `ApplyToPodSpec` which will be false in
case of osd and prepare pods because we don't want to overlap
placement of osd on PVC's and non-PVC's.
Signed-off-by: subhamkrai <srai@redhat.com>
Do not force unit tests to be run while the rook repo is in the GOPATH.
Now that Rook uses go modules, this is no longer necessary. Allow this
by creating a helper function that unit tests can use that return the
on-host path to the `rook` project root.
Signed-off-by: Blaine Gardner <blaine.gardner@redhat.com>
when a node fails some pods remains in terminating while other manage to
be rescheduled on another node successfully.
this commit adds code to clean up all the Rook and CSI pods that are stuck in terminating
state on a failed node.
Signed-off-by: rohan47 <rohgupta@redhat.com>
added waitTimeoutForHealthyOSD in the cluster crd that defines the time (in minutes) the operator would wait before an OSD can be stopped for
upgrade. This PR also removes the ok-to-continue logic for osds as its already handled by ok-to-stop. The default value is 10 minutes.
Signed-off-by: Santosh Pillai <sapillai@redhat.com>
updating to latest Kubernetes version 1.20.0 fix
security issues. In the current version, it allows
for the token leak in logs when logLevel >= 9.
Signed-off-by: subhamkrai <srai@redhat.com>
Currently, mgr deployment has two overlapping environment variables, ROOK_POD_IP.
This causes kube-apiserver to create error logs
Signed-off-by: binoue <banji-inoue@cybozu.co.jp>
The arbiter can only be configured with the stretch cluster if the
CRUSH map is balanced and there are two zones in the CRUSH map.
After the OSDs are configured, we wait for all the OSD pods to be
running and that the CRUSH map is balanced. If it takes more than
two minutes, we fail the reconcile and try again. This is only done
the first time the stretch cluster is configured. In future reconciles
we first check if the stretch cluster is already enabled before
enabling it again.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>