RGW can only serve a single certificate. This limitation means that the
prior behavior of using the default service for admin ops when TLS is
enabled may mean it requires additional complex certificate management
to make sure the object store uses a certificate valid for Rook internal
admin ops and user connections.
This is needlessly complex for users. Instead, change Rook's behavior
and documentation to clarify that it will use the same endpoint intended
for S3 client applications. This means that users have a more
straightforward path to enabling both Rook and consuming applications.
More info: https://github.com/rook/rook/issues/14530
Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
Add CephObjectStore spec.hosting.advertiseEndpoint configuration. This
provides a clear documented default for which endpoint Rook "advertises"
to dependent resources like CephObjectStores, OBCs, and COSI
Buckets/Accesses and allows users to override the default behavior if
desired.
The current default is to round-robin an endpoint from
spec.hosting.dnsNames, which has proven to be troublesome for some
users' object store configurations. This change provides much-needed
disambiguation for users.
This may be a breaking change for some existing spec.hosting.dnsNames
users. This is unexpected but is documented.
Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
In Reef the is_master changed from a string to a bool
so we must update the type for proper json
serialization.
Signed-off-by: travisn <tnielsen@redhat.com>
The radosgw-admin command uses the network spec from ceph cluster spec
in object context but it is not filled properly in the object package.
But with PR 10898, network spec is available in clusterinfo which can
be used directly. Also removed cluserspec from object context.
Signed-off-by: Jiffin Tony Thottan <thottanjiffin@gmail.com>
The tool gofmt in go 1.19 requires certain formatting
in the comments section for better rendering.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
The cluster info is important context for the cluster controller to
create the cluster, and all the fields must be properly set.
A test cluster name was being set temporarily, resulting in
mons incorrectly getting the wrong cluster CR name. There is no
known issue from the temporary value, it was just exposed by
https://github.com/rook/rook/pull/8678 setting the value to a label.
Now the functions are more clearly named so only unit and
integration tests should be using the test value for the cluster
name where it is not important.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
Replace calls to 'radosgw-admin period update --commit' with an
idempotent function.
Resolves#8879
Signed-off-by: Blaine Gardner <blaine.gardner@redhat.com>
The CephClusterSpec was missing from the object context, so the check
for the network provider in RunAdminCommandNoMultisite() was not
discovering the network property correctly.
Signed-off-by: Sébastien Han <seb@redhat.com>
radosgw-admin may output logs before and after JSON when this command succeeds. We should
get rid of these logs before unmarshaling output. Although the logs before JSON were
treated in PR7354, the logs after JSON weren't.
Signed-off-by: Satoru Takeuchi <satoru.takeuchi@gmail.com>
Sometimes `radosgw-admin` succeeds after showing logs to stderr. We should
skip non-json strings if parsing output as json.
Here is an example.
```
2021-02-26 04:10:44.190418 I | op-bucket-prov: creating Ceph user "ceph-user-aSzNqgE7"
E0226 04:11:37.901310 8 controller.go:199] error syncing 'logging/loki-bucket': error provisioning bucket: Provision: can't create ceph user: error creating ceph user "ceph-user-aSzNqgE7": failed to unmarshal json. 2021-02-26T04:11:21.425+0000 7f6714be4980 1 robust_notify: If at first you don't succeed: (110) Connection timed out
2021-02-26T04:11:21.426+0000 7f6714be4980 0 ERROR: failed to distribute cache for ceph-hdd-object-store.rgw.meta:users.uid:ceph-user-aSzNqgE7
2021-02-26T04:11:32.168+0000 7f6714be4980 1 robust_notify: If at first you don't succeed: (110) Connection timed out
2021-02-26T04:11:32.168+0000 7f6714be4980 0 ERROR: failed to distribute cache for ceph-hdd-object-store.rgw.meta:users.keys:23Z8GUEXR0TJDO86PSJR
{
"user_id": "ceph-user-aSzNqgE7",
"display_name": "ceph-user-aSzNqgE7",
...
"mfa_ids": []
}: invalid character '-' after top-level value: failed to unmarshal json.
```
In this case, some logs like "robust_notify:..." was shown in stderr.
Unmarsharing was failed due to tried to parse these logs as json.
Signed-off-by: Satoru Takeuchi <satoru.takeuchi@gmail.com>