This new setting is of Boolean type and defaults to "false".
When set to "true", it changes the behavior of the
rook operator to
nable host network on all pods created by the cephcluster controller
new method to check the setting: opcontroller.EnForceHostNetwork()
Signed-off-by: Michael Adam <obnox@samba.org>
(cherry picked from commit e378588359)
Updating storageClassName for cluster-on-pvc.yaml file from gp2 to gp2-csi.
Signed-off-by: ShravaniVangur <shravanivangur@gmail.com>
(cherry picked from commit 9656d1963a)
Normally the device class of an OSD is determined at provisioning
and is not updated thereafter. In some scenarios the admin may
want to force update the device class to a new value. The device
classes can be updated by first setting allowDeviceClassUpdate
in the storage spec of the cephcluster, then updating the
device class specified on the deviceSets or other OSDs.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
Block devices can move between reboots. In corner cases, an OSDs block
device might move to a lower-indexed device while the previous device
does not exist. For example, an OSD on /dev/sde might move to /dev/sdd
on reboot if the original /dev/sdd died. There would be no /dev/sde
after that.
Users report that NVMe drives commonly change names, even when there are
no disk failures.
For these cases, ensure the activate script properly handles cases where
the previous disk is not present on the node and where the OSD is still
available on a different disk.
Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
Currently we allow upgrade of other OSDs while migration
of OSD, due to change in backing store, is pending. This
will not work if the updated OSD ceph version does not support
the currently applied backing store. So rook will skip any
OSD upgrade if the OSD migration is pending.
Signed-off-by: sp98 <sapillai@redhat.com>
LVM-based OSDs on PVCs are legacy and are not well tested.
Therefore, we add status to the cephcluster CR that at least
gives a clue that the OSDs should be replaced.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
there are some cases where storageClassDeviceSets length
are more 63 chars and osd provisioned failed due to this.
with error
```
failed to run osd provisioning job for PVC "ocs-deviceset-*-local-volume-storageclass-0-data-*": Job.batch "rook-ceph-osd-prepare-*" is invalid: [spec.template.spec.volumes[10].name: Invalid value: "ocs-deviceset-*-local-volume-storageclass-0-data-*": must be no more than 63 characters, spec.template.spec.containers[0].volumeMounts[9].name: Not found: "ocs-deviceset-*-local-volume-storageclass-0-data-*",
```
Using x-validator to limit the maxLength to the deviceClassSet.Name to
40 chars and adding code check that overall pvc name should be less than
63 chars.
Signed-off-by: subhamkrai <srai@redhat.com>
OSDs on LVM-mode PVCs are failing to come up and crashing
in the expand-bluefs init container. To avoid the crash
and allow the OSDs to start, a workaround was found to
simply remove that init container. Now we disable the
OSD resize for this case to avoid others hitting this
during upgrade as well.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
For check if cluster PGs are healthy before osd updates
Which helps gainning more confidence in the osd upgrades
Signed-off-by: mmaoyu <wupiaoyu61@gmail.com>
If device set names are duplicated, the OSDs will be very confused
when multiple OSDs attempt to be configured with the same
device set names. Updating the device set names does not help
get out of the error situation since the OSDs will also be
confused about which device set they belong to. The reconcile
must fail completely if the device set names are duplicated
to avoid this error scenario.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
The key file deletion process is in the shell script commonly used by
all of encryption-open, encryption-open-metadata, and
encryption-open-wal init containers. The key file is deleted at the
encryption-open init container and encryption-open-metadata and
encryption-open-wal init containers are failed to open the key file.
The key file is in the /etc/ceph folder. Unless that folder is shared,
the key file anyway won't be available in the other init containers
even if it is not deleted by these init containers. And it will
naturally anyway be deleted after the init containers are
completed. So The key file deletion process in shell scripts is
unnecessary.
Fixes: #13737
Signed-off-by: Yuma Ogami <yuma-ogami@cybozu.co.jp>
With the release of Reef v18.2.2 we update the default
recommended version of Ceph to fix the prometheus issues
seen with v18.2.1
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
Reduce CRD size by removing some descriptions for things that
(a) are long, (b) are repeated, and (c) are commong kubernetes types.
Remove the `Status` field from VolumeClaimTemplates (a.k.a. PVCs) in
types.go to remove all unnecessary status-related fields.
Use `yq` to go through generated `crds.yaml` to strip out descriptions
for well-known k8s types that are long and repeated where we can't
remove them from types.go. This is mostly placement descriptions and
volumeSource descriptions.
The overall `crds.yaml` file is reduced to less than 60% of its original
size.
Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
Signed-off-by: Redouane Kachach <rkachach@redhat.com>
Co-authored-by: Blaine Gardner <blaine.gardner@ibm.com>
If migration of the OSDs is enabled, operator should wait
for the pgs to be clean after the all the OSDs have reconciled.
This will help add the exponential backoff for the operator
restarts when OSD migration is needed but PGs are still rebalancing the
data after last OSD migration.
Signed-off-by: sp98 <sapillai@redhat.com>
Since v18.2.1 is the default recommendation for the ceph version,
update all the docs and examples to that version.
Signed-off-by: travisn <tnielsen@redhat.com>
This patch adds `pgHealthyRegex` field to DisruptionManagementSpec.
`pgHealthyRegex` is a regular expression that is used to determine which
PG states should be considered healthy. The default value of
`pgHealthyRegex` is:
^(active\+clean|active\+clean\+scrubbing|active\+clean\+scrubbing\+deep)$
which is effectively the same as before.
Signed-off-by: Ryotaro Banno <ryotaro.banno@gmail.com>
During certain maintenance tasks the admin will own running
operations on the ceph mgr, rgw, mds and rbd-mirror daemons
and the operator should not interfere with those operations.
Co-authored-by: gauravsitlani <gaurav.sitlani@live.com>
Signed-off-by: subhamkrai <srai@redhat.com>
When OSDs flap, ceph stops the OSD daemon if its marked down greater than
5 times in 600 seconds. But OSD pod restarts and marks the OSD `up` again.
This causes the PGs mapped to these OSDs to peer. While the PGs are peering,
IO to these PGs are blocked.
So we need to ensure that if ceph is marking OSD `down` due to flapping, OSD pod
should not restart to mark the OSDs `up` again.
This PR adds a sleep to the OSD pod if the container returned with a 0 exit code
Default behavior is to sleep for 6 hrs. But user can configure it from the
ceph cluster spec.
Signed-off-by: sp98 <sapillai@redhat.com>
Change how Rook detects network CIDRs for Multus networks. The IPAM
configuration is only defined as an arbitrary string JSON blob with a
"type" field and nothing more. Rook's detection of CIDRs for whereabouts
had already grown out of date since the initial implementation.
Additionally, Rook did not support DHCP IPAM, which is a reasonable
choice for users. And more, Rook did not support CNI plugin chaining,
which further complicates NADs. Based on the CNI spec, network chaning
can result in any changes to network CIDRs from the first-given plugin.
All these problems make it more and more difficult for Rook to support
Multus by inspecting the NAD itself to predict network CIDRs. Instead,
it is better for Rook to treat the CNI process as a black box. To
preserve legacy functionality of auto-detecting networks and to make
that as robust as possible, change to a canary-style architecture like
that used for Ceph mons, from which Rook will detect the network CIDRs
if possible.
Also allow users to specify overrides for CIDR ranges. This allows Rook
to still support esoteric and unexpected NAD or network configurations
where a CIDR range is not detectable or where the range detected would
be incomplete. Because it may be impossible for Rook to understand the
network CIDRs wholistically while residing only on a portion of the
network, this feature should have been present from Multus's inception.
Improving CIDR auto-detection and allowing users to specify overrides
for auto-detected CIDRs rounds out Rook's Multus support for CephCluster
(core/RADOS) installations. No further architectural changes should be
needed for CephClusters as regards application of public/cluster network
CIDRs for Multus networks.
Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
We need to restart all the ceph daemons whenever
cephCluster network settings are modified like
requiremsgr2, encryption and compression. This
required for Ceph to consider the new settings
it require new ceph daemons all over.
Signed-off-by: subhamkrai <srai@redhat.com>
If osd store is updated in the ceph cluster, then
delete OSDs one by one, cleanup disks and provision a new OSD on
the same disk
Signed-off-by: sp98 <sapillai@redhat.com>
This PR makes Rook operator to add a label on PVC that contains an image version of Ceph when creating an OSD.
Signed-off-by: YZ775 <yuzuki-mimura@cybozu.co.jp>
Signed-off-by: avanthakkar <avanjohn@gmail.com>
Volume "ceph-daemons-sock-dir" is coming empty in case if dataDirHostPath,
which is the case for osd onPVC. Fix the volume creation by using the
ceph cluster spec dataDirHostPath, which allows to run socket commands
on osd containers.
The journal size was only applicable to the filestore OSD
format which has not been supported by rook since v1.2.
Remove the remaining obsolete setting from the examples and
code.
Signed-off-by: travisn <tnielsen@redhat.com>
The defaults in CRDs cause an update and trigger a new
reconcile if the value is not set. For the key rotation
setting, the default was only being updated when the kms
feature was enabled. This update was causing the reconcile
to fail in the kms tests. With the default now in code,
the default can remain empty and no cr update will trigger
a new reconcile unexpectedly.
Signed-off-by: travisn <tnielsen@redhat.com>