With octopus coming to end of life, we remove support from
Rook for deploying Ceph Octopus and assume a min version of
Pacific v16. Any checks for octopus or earlier are removed
from the reconciles since they are obsolete.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
This removes double package imports. Example:
```
"github.com/rook/rook/pkg/apis/ceph.rook.io/v1"
cephv1 "github.com/rook/rook/pkg/apis/ceph.rook.io/v1"
```
Only one is now being used as shown in go-staticcheck ST1019
Signed-off-by: Alexander Trost <galexrt@googlemail.com>
Added unit test for probes changes and
did re-naming of liveness probes file
as it will contain multiple types of probes
Signed-off-by: parth-gr <paarora@redhat.com>
The cluster info is important context for the cluster controller to
create the cluster, and all the fields must be properly set.
A test cluster name was being set temporarily, resulting in
mons incorrectly getting the wrong cluster CR name. There is no
known issue from the temporary value, it was just exposed by
https://github.com/rook/rook/pull/8678 setting the value to a label.
Now the functions are more clearly named so only unit and
integration tests should be using the test value for the cluster
name where it is not important.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
We don't need to use tini.
We don't have anything in the rook operator that would
either create zombie processes (no threads) or use
exec (to fork). The Go binary has a really good
signal handling mechanism.
Closes: https://github.com/rook/rook/issues/8794
Signed-off-by: Sébastien Han <seb@redhat.com>
The flex driver has been fully deprecated and thus removed from Rook.
Before upgrading to v1.8, users will need to convert existing flex volumes
from flex to csi volumes.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
earlier, we had the issue for osd placement regarding
whether we should merge the placements or not.
Now, we have option `skipApplyAllPlacement` to
enable/disable osd placement. By default it is false
which means it will merge both placement.All() and
storageClassDeviceSets.Placement, when true
it will only apply storageClassDeviceSets.Placement.
Also, adding unit test.
Closes: https://github.com/rook/rook/issues/8135
Signed-off-by: subhamkrai <srai@redhat.com>
Recently, the builds of `ceph/ceph` image moved to quay.io, see
https://github.com/ceph/ceph-build/pull/1883 for more details.
Current images will remain but new builds will happen on quay.io only.
This means that tags such as `v14.2`, `v15.2`,`v16.2` will need to
switch to quay.io to get updates.
Signed-off-by: Sébastien Han <seb@redhat.com>
when osd pods removed, they are not able
to add back due to missing `ceph auth`
or different `ceph auth`.
this commit mounts the secret `rook-ceph-admin-keyring`
inside the osd activate initcontainer which has
admin keyring.
Signed-off-by: subhamkrai <srai@redhat.com>
We don't need to pass the Volume with projection for TLS when TLS is not enabled
Somehow when this happens and we try to update a deployment spec it fails with:
```
ValidationError(Pod.spec.volumes[7].projected): missing required field "sources"
```
Signed-off-by: Sébastien Han <seb@redhat.com>
The rook.io/v1 package was only an internal implementation detail and
does not have any CRDs that rely on it. The CRD deserialization should
handle the change in internal types without any issue. This separation
gives more flexibility for the storage providers to implement exactly
what is needed for their storage provider instead of forcing to use the
same types and risk affecting another storage provider.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
The VolumeSource type was only used internally when loading
the storageClassDeviceSets. The volumeSource element is never
expected to be specified in the CephCluster CR, so it is now
removed from the schema. The VolumeSource type is renamed to
deviceSet for clarity.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
Update OSDs in parallel per the design in
design/ceph/update-osds-in-parallel.md
The max number of OSDs updated in parallel is currently fixed at 20.
Signed-off-by: Blaine Gardner <blaine.gardner@redhat.com>
When running encrypted OSDs on multipath the expand container was
failing to find the underlying device of the encrypted block. This was
because the underlying block was located in /dev/mapper and this path
wasn't mounted in the init container "expand-encrypted-bluefs".
This will manifest like so:
```
Underlying device for crypt device ocs-deviceset-block-dev-from-san-1-data-0-5qkmm-block-dmcrypt disappeared.
```
Signed-off-by: Sébastien Han <seb@redhat.com>
It's better to validate ownerReferences when setting them. In addition, we should use
controllerrutil.Set{Controller,Owner}Reference, that have such validation, as possible.
Signed-off-by: Satoru Takeuchi <satoru.takeuchi@gmail.com>
The mgr daemon may be failed over by ceph if the active mgr is not
responding and the standby mgr is available. If the active mgr changes
the services for the dashboard and metrics will be updated with a
label selector for the new active mgr. The services cannot direct
traffic to the standby mgr or else they will be incorrectly redirected
to the active mgr.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
For simple OSD scenario that don't require the following:
* an encrypted osd
* an osd with a backing device
* multiple osd on the same block device
The OSD will be prepared using the ceph-volume raw mode which does
not use LVM on non-pvc case.
Closes: https://github.com/rook/rook/issues/4768
Signed-off-by: Sébastien Han <seb@redhat.com>
If HostPID is enabled, this means the Ceph version is older than Octopus
and we are still running OSD with HostPID due to an internal
inter-process check.
If the log collector is enabled we need to enable ShareProcessNamespace
**only** if HostIPC is disabled.
Both HostPID and ShareProcessNamespace cannot be enabled.
Signed-off-by: Sébastien Han <seb@redhat.com>
The settings for tuneDeviceClass and tuneFastDeviceClass were
stored as a map[string]string. When iterating over the map to
append the args, the args were being appended in an unpredictable
order. The order could change every reconcile, resulting in an
unnecessary OSD restart potentially every reconcile. Now we iterate
over a slice that will be ordered predictably and ensure OSDs
will not be restarted when not needed.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
Currently, mgr deployment has two overlapping environment variables, ROOK_POD_IP.
This causes kube-apiserver to create error logs
Signed-off-by: binoue <banji-inoue@cybozu.co.jp>
When the Ceph cluster runs on PVC and the OSDs are encrypted we can
store LUKS's Key Encryption Key inside a Key Management System. Today,
Rook only supports HashiCorp Vault: https://www.vaultproject.io/
The CephCluster has now a new "security" field which will plug onto the
KMS. Here is an example:
security:
kms:
tokenSecretName: <name of the secret containing a Vault token, used
to authenticate>
connectionDetails: < a map of strings containing connection
information>
Refer to the ceph-cluster-crd documentation to lear more.
Closes: https://github.com/rook/rook/issues/6105
Signed-off-by: Sébastien Han <seb@redhat.com>
The CRUSH map does not allow duplicate values (nor keys) for the
labels. That means that if the currently hardcoded label value
`default` occurs anywhere else in the tree (for example, because
some of the topology labels provided by the cloud provider use it),
the cluster cannot sucessfully spawn.
By giving the user control over the label value used for the root
CRUSH map label, it is possible to adapt the cluster to this
situation.
To be able to actually use the `default` value, the root=default
node which is created by default by ceph itself has to be removed;
since that node is accompanied by a replicated crush rule, we have
to remove that rule, too.
The integration tests are modified to sometimes use the custom
crushRoot (based on an arbitrary criterium) to get coverage across
the various suites. Separate tests could be added, but were not
deemed necessary at this point.
Fixes#4993.
Signed-off-by: Jonas Schäfer <jonas.schaefer@cloudandheat.com>
We can now tune the value of TCMALLOC_MAX_TOTAL_THREAD_CACHE_BYTES by
setting an annotation on the CephCluster CRD like so:
```
annotation:
osd:
TCMALLOC_MAX_TOTAL_THREAD_CACHE_BYTES: "134217728"
```
Alternatively, if nothing is specified Rook will read the value of the
file `/etc/sysconfig/ceph`.
Closes: https://github.com/rook/rook/issues/6134
Signed-off-by: Sébastien Han <seb@redhat.com>
on Azure, all SSDs are reporting as a rotational disk.
This commit will add `tuneFastDeviceClass` flag which will
tune for an SSD even if the cloud provider is reporting
rotational. We have a flag `tuneDeviceClass`
which works vice-versa.
Signed-off-by: subhamkrai <srai@redhat.com>
The OSD deployments have some env vars duplicated in the pod spec for
the daemon container, which may cause the detection for patch changes
to fail. Now we ensure the env vars are not duplicated in the OSD pod
spec.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
Added more unit tests scenario for osd on pvc such as:
* block/db/wal
* block encryption
* block/db encryption
* block/db/wal encryption
Signed-off-by: Sébastien Han <seb@redhat.com>
Now the metadata pvc will also be encrypted if the storageClassDeviceSet
has the "encrypted" flag turned on.
Signed-off-by: Sébastien Han <seb@redhat.com>
Based on the feature of metadata PVC for OSD: #4818, add the wal device.
For this, you need to create a new volumeClaimTemplates, its name must be "wal", if "wal" is
set, "metadata" device will refers specially for block.db device, and "wal" refers for block.wal
device in BlueStore.
A template will look like this:
```
volumeClaimTemplates:
- metadata:
name: data
spec:
resources:
requests:
storage: 10Gi
# IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, gp2)
storageClassName: gp2
volumeMode: Block
accessModes:
- ReadWriteOnce
- metadata:
name: metadata
spec:
resources:
requests:
storage: 6Gi
# IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, io1)
storageClassName: io1
volumeMode: Block
accessModes:
- ReadWriteOnce
- metadata:
name: wal
spec:
resources:
requests:
storage: 6Gi
# IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, io1)
storageClassName: io1
volumeMode: Block
accessModes:
- ReadWriteOnce
```
We now map block, block.db and block.wal directly inside the container instead of
running ceph-volume activate.
Signed-off-by: Chen, Tingjie <tingjie.chen@intel.com>
To provide more context for executing commands in a ceph cluster,
the full clusterInfo is now passed to the ceph execution commands.
All information about the cluster will now be available throughout
all the areas of the operator. The namespace, ceph credentials,
mon endpoints, and other info is a core part of that cluster info.
Arguments passed through the controllers are also simplified for
mons, mgr, osds, and other daemons where the parameters had
become too complex.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
The ceph config and client packages are conceptually the same.
To avoid circular dependencies in some cases, we simplify by combining
the packages into the client package.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
Add the ability to provision Ceph OSDs with Drive Groups.
This adds Drive Groups to the CephCluster CRD, and it sets code
in place for propagating this config to the OSD provisioning pod.
Signed-off-by: Blaine Gardner <blaine.gardner@suse.com>
This commit allows us to configure status check for each daemon:
* "mon": health check on the ceph monitors (quorum)
* "osd": health check on the ceph osds
* "status": ceph health status check
Each check is controlled by the following settings:
* disabled: whether to disable the check (default: false)
* internal: interval to run the check
* timeout: only valid for mons, is the timeout for unresponsive mon
before failling over.
Example to disable the status health check:
```yaml
healthCheck:
daemonHealth:
status:
disabled: true
```
As part of that, pod's livenessprobe can now be configured via the
following settings:
* disabled: whether to enable or not
* probe: override the current probe in place by a new one
```yaml
healthCheck:
livenessProbe:
mon:
disabled: true
```
Closes: https://github.com/rook/rook/issues/5772
Signed-off-by: Sébastien Han <seb@redhat.com>
Update the base operator image and cluster examples to use the latest
octopus release v15.2.4. Also cleanup some old examples and unit tests
that were still based on mimic.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
The OSD needs to talk to the udev socket to get information about a device.
like serial, vendor etc. So that it can populate the output of:
`ceph osd metadata $n` correctly.
Signed-off-by: Sébastien Han <seb@redhat.com>
The rook types used across the storage providers moved from the v1alpha2
package to the v1 package. This commit points the packages at their new
location. Implementation is expected to remain unchanged.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
When running on PVC, if the backend resizes the block, Rook will expand
it and the size of the OSD will grow.
Signed-off-by: Sébastien Han <seb@redhat.com>
We now support the addition of the PVC that acts as a metadata device
for a given OSD.
For this, you need to create a new `volumeClaimTemplates`, its name must
be "metadata" otherwise, Rook won't pick it up.
A template will look like this:
```
volumeClaimTemplates:
- metadata:
name: data
spec:
resources:
requests:
storage: 10Gi
# IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, gp2)
storageClassName: gp2
volumeMode: Block
accessModes:
- ReadWriteOnce
- metadata:
name: metadata
spec:
resources:
requests:
storage: 6Gi
# IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, gp2)
storageClassName: gp2
volumeMode: Block
accessModes:
- ReadWriteOnce
```
We now map block and block.db directly inside the container instead of
running ceph-volume activate. This is much cleaner.
Closes: https://github.com/rook/rook/issues/3852
Signed-off-by: Sébastien Han <seb@redhat.com>
We now always perform ok-to-stop change when the deployment is going to
be updated. This could be for various reasons like change in the spec or
a new Ceph image.
In any case, if Ceph resources are going to be restarted this must be
done carefully.
Also trimmed the isUpgrade variable, the upcoming commit will remove the
need of that variable.
Keeping isUpgrade from the controller code since we need it to detect
whether an orchestration upgrade should be triggered or not (based on
the ceph cluster status).
Also, we keep it on the child controllers so we don't go into an
orchestration phase if the cluster image hasn't changed. The child does
not need to be updated/go into its orchestration phase because the
cluster CR changed.
Closes: https://github.com/rook/rook/issues/4379
Signed-off-by: Sébastien Han <seb@redhat.com>
Multiple things:
1. We removed all the function/methods/tests that were used to
create and manage rook legacy OSDS as well as bringing support to
Bluestore OSD only.
It also fixes various go-lint issues in the respectives files.
2. use c-v inventory to detect available devices:
Now we rely on the 'ceph-volume inventory' command to tell us if a
device is available or not.
3. implement raw mode for osd on pvc
When an OSD will be bootstrap on a PVC, the new c-v raw mode will be
used. It consists of putting block, db and wal under the same device.
Here LVM is out of the picture and the raw device is used as is. The
implementation is backward compatible so existing OSD on PVC will LVM
will continue to operate.
Closes: https://github.com/rook/rook/issues/4363
Signed-off-by: Sébastien Han <seb@redhat.com>
Now, we purely rely on what the user puts in the CR and apply it.
Prior to this commit we were putting 0 if not declared, this was not the
intentional.
Closes: https://github.com/rook/rook/issues/4713
Signed-off-by: Sébastien Han <seb@redhat.com>
A new CRD option `continueUpgradeAfterChecksEvenIfNotHealthy` is added.
When upgrading, Rook goes OSD by OSD and then waits for PGs to be clean
before proceeding to the next OSD. Currently, Rook waits for 5 hours but
there might be circumstances where PGs need more time to settle.
Thus setting `continueUpgradeAfterChecksEvenIfNotHealthy` to true will
pursue the upgrade process, even if PGs are not 100% active+clean.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1786029
Signed-off-by: Sébastien Han <seb@redhat.com>