Now, the CephBlockPool CRD is managed with the controller-runtime.
So the watcher is outside of the main controller reconciliation loop of
CephCluster which brings numerous benefit such as:
* having its own reconciliation loop
* won't block anything from the main CephCluster controller loop
* fast than waiting for CephCluster loop to completion
Partially close: https://github.com/rook/rook/issues/1981
Signed-off-by: Sébastien Han <seb@redhat.com>
The rook types used across the storage providers moved from the v1alpha2
package to the v1 package. This commit points the packages at their new
location. Implementation is expected to remain unchanged.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
When the OSD on PVC is backed by a metadata block PVC, the Ceph CRUSH
device class should be set to something else rather than the rotational
property of the drive.
Closes: https://github.com/rook/rook/issues/4881
Signed-off-by: Sébastien Han <seb@redhat.com>
We now support the addition of the PVC that acts as a metadata device
for a given OSD.
For this, you need to create a new `volumeClaimTemplates`, its name must
be "metadata" otherwise, Rook won't pick it up.
A template will look like this:
```
volumeClaimTemplates:
- metadata:
name: data
spec:
resources:
requests:
storage: 10Gi
# IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, gp2)
storageClassName: gp2
volumeMode: Block
accessModes:
- ReadWriteOnce
- metadata:
name: metadata
spec:
resources:
requests:
storage: 6Gi
# IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, gp2)
storageClassName: gp2
volumeMode: Block
accessModes:
- ReadWriteOnce
```
We now map block and block.db directly inside the container instead of
running ceph-volume activate. This is much cleaner.
Closes: https://github.com/rook/rook/issues/3852
Signed-off-by: Sébastien Han <seb@redhat.com>
TuneSlowDeviceClass wasn't part of the StorageClassDeviceSet types but
only in VolumeSource which is not exposed in the CR spec so setting the
option would never work.
The only issue is that this apply to all volumeClaimTemplates
where each can point to a particular storage class...
Signed-off-by: Sébastien Han <seb@redhat.com>
When using the "errors" package, using `%+v` (extended format),
each Frame of the error's StackTrace will be printed in detail.
Let's only print `%v` to print the error.
If the error has a Cause it will be printed recursively.
Basically `%+v` has been replaced with `%v` for all `error` type
interfaces, whether the logger is Info, Warning or Error.
Signed-off-by: Sébastien Han <seb@redhat.com>
OSD on PVC does not upgrade when the user upgrades the ceph version on cluster-on-pvc yaml.
The solution incudes:
- upgrade osd prepare and daemon pods on upgrade
- skip c-v prepare if filesystem is already present on the pvc device.
- skip lvm release in case of upgrade.
Signed-off-by: Santosh Pillai <sapillai@redhat.com>
- Added code to support StorageClassDeviceSet spec provided in the cluster-on-pvc.yaml
- The code reads the StorageClassDeviceSet spec and creates pvc based on the ‘count’ field for each device set.
- OSD prepare job is started for each PVC which activates the ceph-volume on each PVC
- Finally OSD is started on each of the PVC device.
Co-authored-by: rohan47 <rohgupta@redhat.com>
Co-authored-by: Ashish Ranjan <aranjan@redhat.com>
Signed-off-by: Santosh Pillai <sapillai@redhat.com>