Now, the CephBlockPool CRD is managed with the controller-runtime.
So the watcher is outside of the main controller reconciliation loop of
CephCluster which brings numerous benefit such as:
* having its own reconciliation loop
* won't block anything from the main CephCluster controller loop
* fast than waiting for CephCluster loop to completion
Partially close: https://github.com/rook/rook/issues/1981
Signed-off-by: Sébastien Han <seb@redhat.com>
As of Octopus, Ceph will prevent you from creating a pool with a
replica size of 1. Allowing such pool could lead to data loss, so enable
the new option: requireSafeReplicaSize: false if you are **ABSOLUTELY**
certain that is what you want.
Closes: https://github.com/rook/rook/issues/4889
Signed-off-by: Sébastien Han <seb@redhat.com>
This commit is to handle all those unhandled errors which raises the gosec warning.
Fixed G104: Unhandled Errors are handled now
Signed-off-by: Nizamudeen <nia@redhat.com>
When the cluster is upgraded, the child controllers are notified with the
callback to the ParentClusterChanged() method. These should be made
in a separate goroutine so that the cluster controller is not blocked
on the child controllers and also so child controllers aren't blocked
on each other for the upgrade.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
We now always perform ok-to-stop change when the deployment is going to
be updated. This could be for various reasons like change in the spec or
a new Ceph image.
In any case, if Ceph resources are going to be restarted this must be
done carefully.
Also trimmed the isUpgrade variable, the upcoming commit will remove the
need of that variable.
Keeping isUpgrade from the controller code since we need it to detect
whether an orchestration upgrade should be triggered or not (based on
the ceph cluster status).
Also, we keep it on the child controllers so we don't go into an
orchestration phase if the cluster image hasn't changed. The child does
not need to be updated/go into its orchestration phase because the
cluster CR changed.
Closes: https://github.com/rook/rook/issues/4379
Signed-off-by: Sébastien Han <seb@redhat.com>
We now force the mds daemon to join the fs that was created by Rook.
This can always be changed by using the ceph config store.
Closes: https://github.com/rook/rook/issues/4707
Signed-off-by: Sébastien Han <seb@redhat.com>
With this modification is guaranteed that at least 1 MDS pod is going to be
placed in each of the available zones in the k8s cluster.
This would be improved in the future using:
<Pod Topology Spread Constraints> (still in alpha state since kubernetes V.1.16)
This modification obtain the number of zones in the k8s cluster and appends an
<antiaffinity> term using the topologyKey
<topology.kubernetes.io/zone> in the same number of MDS pods.
In the case that will be more MDS pods than zones, the <antiaffinity> term won't
be added in these extra pods.
Important Note:
The antiaffiniy term only will work with nodes labeled using the NEW label:
<topology.kubernetes.io/zone> present in k8s V.1.17 clusters.
For previous versions of k8s clusters the label used is:
<failure-domain.beta.kubernetes.io/zone>
And therefore, in this kind of clusters this modification won't work.
Resolves#4641
[test ceph]
Signed-off-by: Juan Miguel Olmo Martínez <jolmomar@redhat.com>
A new CRD option `continueUpgradeAfterChecksEvenIfNotHealthy` is added.
When upgrading, Rook goes OSD by OSD and then waits for PGs to be clean
before proceeding to the next OSD. Currently, Rook waits for 5 hours but
there might be circumstances where PGs need more time to settle.
Thus setting `continueUpgradeAfterChecksEvenIfNotHealthy` to true will
pursue the upgrade process, even if PGs are not 100% active+clean.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1786029
Signed-off-by: Sébastien Han <seb@redhat.com>
The operator kit had more utility originally when the operator
was creating and managing the TPRs and CRDs directly. Since
the CRDs are now created from a manifest and no longer by the
operators, the utility of operator kit is limited to the
controller watcher. Since we are moving to the controller runtime
we simplify the code to make the transition smoother. Now
there is only a simple WatchCR method that will need to be
replaced as we maek that transition.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
This commit adds status field for ceph related CRs which will be useful for knowing the ceph component status without checking the logs.
Signed-off-by: Ashish Ranjan <ashishranjan738@gmail.com>
Reduce from 5 minutes to less than 50 seconds the time needed to restart a
mgr and osds(PVCs based),rgw,mds,rbd,nfs and toolbox pod that was running
in a k8s "NotReady" Node.
A new Rook Operator setting has been added to allow the user to set the
time used in pod's toleration <node.kubernetes.io/unreachable>:
ROOK_UNREACHABLE_NODE_TOLERATION_SECONDS = <5>
New setting added in release notes
Addressed @travisn,@leseb, and @blaineEXE suggestions
Signed-off-by: Juan Miguel Olmo Martínez <jolmomar@redhat.com>
When using the "errors" package, using `%+v` (extended format),
each Frame of the error's StackTrace will be printed in detail.
Let's only print `%v` to print the error.
If the error has a Cause it will be printed recursively.
Basically `%+v` has been replaced with `%v` for all `error` type
interfaces, whether the logger is Info, Warning or Error.
Signed-off-by: Sébastien Han <seb@redhat.com>
We recently discovered a race condition which happens not to update the
child CRDs when CR image changes.
The race happens under the following sequence:
* orchestration onAdd() is called when the operator image restarts
or its image updated
* the orchestration then goes into processing mon/mgr/osd
* during this the cluster CR is updated so onUpdate() is called,
however, onAdd() is not done yet for child CRDs (mds, rgw)
* onUpdate() runs against the cluster CR and updates the cluster images
* by the time the child CRDs reached onUpdate() from their respective
ParentClusterChanged() methods, the image is already up to date
so we were exiting since our check for updating
these resources are based on the cluster image version
To fix this, we changed the comparison, but using isUpgrade instead and
slightly changed the way isUpgrade operates. So now, isUpgrade is true
even if the Ceph version is identical which allows us to verify whether
or not the image changed.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1775624
Signed-off-by: Sébastien Han <seb@redhat.com>
The Ceph Mimic release introduced the monitor config store which allows
us to set configuration flag per daemon in a centralized fashion. Let's
use it for Mimic and newer and keep the CLI flag of daemon startup for
older versions.
The main benefit is that the config of a daemon can now be overridden.
Also, this commit refactors some code and add methods that are unit
tested.
Closes: https://github.com/rook/rook/issues/4307
Signed-off-by: Sébastien Han <seb@redhat.com>
Checking for isUpgrade is irrelevant since we need to restart the
deployment because the the spec has changed, the only thing that might
change is whether or not we perform upgrade checks.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1775624
Signed-off-by: Sébastien Han <seb@redhat.com>
This change standardizes the ownerRefs of Ceph keyrings to
k8s Deployment resources across all daemons and refactors a
bit of duplicate code on keyring association for ease of
maintenance.
Fixes: #4089
Signed-off-by: egafford <egafford@redhat.com>
Failure to create a keyring prior to creating a deployment
dependent on that keyring created a race conditition resulting
in an intermittent and unnecessary pod failure. This change
creates a keyring prior to deployment creation for MDS
daemons.
Partially fixes: rook#4089
Signed-off-by: egafford <egafford@redhat.com>
The command `fs new` already enable the application pool settings for
the cephfs pools so we don't need to run that command again.
Signed-off-by: Sébastien Han <seb@redhat.com>
Following the Ceph OSD rework, my test environment regularly failed to
start OSDs, as they would start before the postStart lifecyle hook which
was chown'ing the log and data directories could finish. Pods failed to
start for an arbitrarily long time before starting successfully. This
was a manifestation of a race condition identified in Ceph monitors in
https://github.com/rook/rook/pull/3594#discussion_r312279176
Create a Ceph operator-level method to create an init container that
will chown the necessary directories for all Ceph daemons (any daemon
which runs as the ceph:ceph user-and-group). Also add this container to
expectations for Ceph pod templates in unit tests.
Signed-off-by: Blaine Gardner <blaine.gardner@suse.com>
The resources for rgw, mds, and nfs were being cleaned up explicitly when
the CR was deleted. This is legacy from before the owner references were
set on the CRs. Now the owner references are set to the appropriate CRs so
the resources will be cleaned up upon deletion of the specific CR
rather than the cluster CR.
Signed-off-by: travisn <tnielsen@redhat.com>
We now differentiate the cases where:
* we only consume the external cluster
* we consume the external cluster as well as creating stateless
resources in Kubernetes (bootstrap mds,rgw, nfs)
This is mostly controlled via the image property spec. If not defined,
not extra CRs won't be able to be created.
Now the external cluster feature supports Ceph cluster as of Luminous 12.2.
Signed-off-by: Sébastien Han <seb@redhat.com>
A new CRD property `PreservePoolsOnDelete` has been added to Filesystem(fs) and
Object Store(os) resources in order to increase protection against data loss.
If it is set to `true`, associated pools won't be deleted when the main
resource(fs/os) is deleted. Creating again the deleted fs/os with the same name
will reuse the preserved pools.
Signed-off-by: Juan Miguel Olmo Martínez <jolmomar@redhat.com>
On rare occasion, the ceph checks might not be 100% correct and the user
might decide to force an upgrade anyway.
Correctly, if we are in an upgrade, we perform `ok-to-stop` check for
each daemon, if one of them fails, we retry and eventually fail.
They are corner-cases where users would like to force the upgrade anyway.
Enhance the new CR property: "skipUpgradeChecks: true".
Closes: https://github.com/rook/rook/issues/3872
Signed-off-by: Sébastien Han <seb@redhat.com>
Reduce the duplication of detecting the version of the external cluster
by refactoring to a single method that retrieves and validates the
version
Signed-off-by: travisn <tnielsen@redhat.com>
Add various upgrade tests so that the local cluster does not fail if
an upgrade is available on the external cluster.
Also, add better upgrades handling on update and on add. We now rely as
much as possible on a unique function that works both local and external
cluster 'detectAndValidateCephVersion()'. So the code will act the same
way wether a CR update is triggered or if the operator is restarted.
The health check now reports any topology changes on the external
cluster such as odd number of mons and low number. It will also detect
if the external cluster has been upgraded and will log that information,
helping the admin in his/her decision to trigger an image upgrade.
Finally, we prevent the creation of new CRs if the external cluster
version has a higher major number than the local one.
Closes: https://github.com/rook/rook/issues/3731
Signed-off-by: Sébastien Han <seb@redhat.com>
From now on, Rook will only perform check before upgrades when there is
an actual upgrade. So if the Ceph image changed and a new version is
desired Rook will go through all the daemons and update them one by one
and perform checks in between.
Closes: https://github.com/rook/rook/issues/3583
Signed-off-by: Sébastien Han <seb@redhat.com>
ceph: Use the new NetworkSpec api
ceph: Change all tests to use the NetworkSpec
ceph: Remove TypeMeta field from NetworkSpec
ceph: Change IsHost network func signature
Signed-off-by: giovanism <giovanism@outlook.co.id>
We can now deploy all the other Rook's CRDs. They will be deployed in
Kubernetes but will consume the external cluster storage.
Signed-off-by: Sébastien Han <seb@redhat.com>
When configuring an external cluster the orchestration of discover and all the ceph
daemons will be skipped. The operator will still watch for the creation of
crds for this namespace. When a filesystem, object, object user, or
ganesha crd are created, the operator will simply print an error
to the log.
Signed-off-by: travisn <tnielsen@redhat.com>
Signed-off-by: Sébastien Han <seb@redhat.com>
When configuring an external cluster the orchestration of discover and all the ceph
daemons will be skipped. The operator will still watch for the creation of
crds for this namespace. When a filesystem, object, object user, or
ganesha crd are created, the operator will simply print an error
to the log.
Signed-off-by: travisn <tnielsen@redhat.com>
Signed-off-by: Sébastien Han <seb@redhat.com>
When deleting mds deployment the error is logged, but not propagated
further down (it always returns nil). The two places using the function
checks the error, and acts upon it.
Signed-off-by: Odin Ugedal <odin@ugedal.com>
With the 1.1 release we should not be creating bluestore OSDs
with rook's legacy partitioning scheme. All new bluestore OSDs
should be created with ceph-volume. Therefore, the miminum
version allowed is a version of mimic supporting ceph-volume.
This commit also adds consistent version checking between
the Add and Update methods for the operator handling the
CR events.
Signed-off-by: travisn <tnielsen@redhat.com>
Before each pod starts, the daemon changes the ownership of
/var/log/ceph which is bindmounted on a hostPath.
On OpenShift envionments, the container must be privileged in order to
successfully change the owernship.
Closes: https://github.com/rook/rook/issues/3485
Signed-off-by: Sébastien Han <seb@redhat.com>
At the beginning of every container startup we now change the ownership
of every known ceph directories to ceph:ceph.
This will allow daemons to start properly as well as allowing daemon to
writes their logs on files.
This is needed because ceph daemon now run as 'ceph' instead of 'root'
Signed-off-by: Sébastien Han <seb@redhat.com>
We do not determine the daemon type and name by string parsing anymore
but passing that info directly in the update call, it's more reliable.
Also removing a bunch of unused functions.
Signed-off-by: Sébastien Han <seb@redhat.com>
Do not consider clusterInfo Ceph version since it's the one picked by
the spec image.
The CephVersion provided here needs to be the current running version
of Ceph for when it is later passed to OkToStop and checked with
IsAtLeast. If you are upgrading from a pre 14.2.1 version to a
version 14.2.1 or newer, IsAtLeast will incorrectly return true and
then fail trying to run mon ok-to-stop on a mon pod running a pre 14.2.1 version.
Signed-off-by: Sébastien Han <seb@redhat.com>
When a cluster is updated with a different image version, this triggers
a serialized restart of all the pods. Prior to this commit, no safety
check were performed and rook was hoping for the best outcome.
Now before doing restarting a daemon we check it can be restarted. Once
it's restarted we also check we can pursue with the rest of the
platform. For instance, with monitors we check that they are in quorum,
for OSD we check that PGs are clean and for MDS we make sure they are
all active.
Fixes: https://github.com/rook/rook/issues/2889
Signed-off-by: Sébastien Han <seb@redhat.com>
In the 0.9 release rook converted the v1beta1 CRD resources
to v1 resources. This conversion code is no longer necessary
as we will be using v1 resources going forward.
The code paths will not be triggered anymore, thus
removing the dead code.
Signed-off-by: travisn <tnielsen@redhat.com>
The check for whether to set the OwnerReferences is no longer
necessary. When passing the correct value to the apiVersion,
the OwnerReferences can be successfully set for OpenShift.
Signed-off-by: travisn <tnielsen@redhat.com>
This commit does multiple things:
* remove support for AllNodes where we would deploy one rgw per node on
all the nodes.
* a transition path is implemented in the code so that if someone has an
existing deployment, daemonsets will be removed and replaced by an
deployments.
* when using "instances", each rgw deployed has its own key which makes
Ceph reporting the exact number of rgw running, see:
```
[root@rook-ceph-operator-775cf575c5-bh4sr /]# ceph -s
cluster:
id: 611fcf39-0669-4864-9a12-debb35c0397a
health: HEALTH_OK
services:
mon: 3 daemons, quorum a,b,c (age 12h)
mgr: a(active, since 12h)
osd: 3 osds: 3 up (since 12h), 3 in (since 12h)
rgw: 3 daemons active (my.store.a, my.store.b, my.store.c)
data:
pools: 6 pools, 600 pgs
objects: 235 objects, 3.8 KiB
usage: 3.0 GiB used, 84 GiB / 87 GiB avail
pgs: 600 active+clean
```
Closes: https://github.com/rook/rook/issues/2474, https://github.com/rook/rook/issues/2957 and https://github.com/rook/rook/issues/3245
Signed-off-by: Sébastien Han <seb@redhat.com>
The CephCluster CR contains settings that are needed by other
CRs to configure the Ceph daemons. When the CephCluster CR
is updated, the updates will now be passed on to each of the
CR controllers to ensure the daemons are updated properly
without requiring an operator restart.
When calling the controllers from another controller,
we ensure that only a single goroutine is handling
CRs at any given time to prevent contention across
multiple CRs of the same type.
Signed-off-by: travisn <tnielsen@redhat.com>