We can now explicitly set any property on a given pool by using the new
Property field in the CephBlockPool Spec.
Also, this fixes the case where both `CephBlockPool` and `CephCluster`
are created at the same time. When Rook creates the pool, the cluster is
still being bootstrapped and the global option
`osd_pool_default_pg_autoscale_mode` has not bee set yet. So the pool
gets created but its `pg_autoscale_mode` property is set to `warn`
instead of `on`.
Closes: https://github.com/rook/rook/issues/5608V
Signed-off-by: Sébastien Han <seb@redhat.com>
ceph mds deactivate is not valid command for Nautilus, changing the mechnaism of upgrading so that it can be done in the way Nautilus does it.
Closes: https://github.com/rook/rook/issues/5278
Signed-off-by: RAJAT SINGH <rajasing@redhat.com>
This is the final conversion to controller-runtime conversion. This time the
CephCluster CRD has been converted to use the controller-runtime
library.
The controller incorporates all the previous watchers too, so the Node
and hot-plug configmap are been watched too.
Only the operator setting configmap is not being watcher since it's not
related to the CephCluster CRD.
Not only the patch converts to controller-runtime but also tries to
re-organize the tree of the repo to actually make the code more
readable and have better functions/methods/tests separations.
Closes: https://github.com/rook/rook/issues/4939
Signed-off-by: Sébastien Han <seb@redhat.com>
Remove specific mds config added to the mon configuration database when deleting a CephObjectstore
or when scaling down number of mds
Also remove mds CephX key
Signed-off-by: n.fraison <n.fraison@criteo.com>
CSI CephFS provisioner fails to provision a Persistent Volume after upgrading from Rook Ceph Operator 1.1.2 to 1.1.7.
This issue can be fixed by removing givePoolAppTag function whenever there is an appName cephFs.
Signed-off-by: RAJAT SINGH <rajasing@redhat.com>
When updating the status on resources sometimes the update fails due to
the resource being an outdated version. This frequently occurs when
the same reconcile loop updates the status multiple times, or the finalizer
is added, or some other update to the resource. Upon the next reconcile
the error would generally go away since the status or finalizer didn't
need to be updated multiple times. But now the error is not expected
since the controller will retrieve the latest version of the resource
immediately before attempting to update it.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
The old Filesystem's pool is not getting updated when changed with the new File system.
So, we added two helper functions namely generateDataPoolNames and generateMetaDataPoolName that will generate the names of the pools and then change those pool's values using the SetPoolSize method.
Signed-off-by: RAJAT SINGH <rajasing@redhat.com>
You can now use Rook along with Multus. Multus must be up and running
and the right ressources must exist such as NetworkAttachmentDefinition
CR.
The Cluster CR spec has new fields to work with multus:
network:
provider: multus (or 'host' for hostNetworking)
selectors:
public: NetworkAttachmentDefinition name
cluster: NetworkAttachmentDefinition name
If only a single NetworkAttachmentDefinition is provided Rook will use
both anyway for the Ceph traffic.
Please refer to the doc to learn more.
Closes: https://github.com/rook/rook/issues/4716
Signed-off-by: Sébastien Han <seb@redhat.com>
This type was a string already and was just making us doing string()
calls all the time to it's not worth it.
Signed-off-by: Sébastien Han <seb@redhat.com>
Now Kubernetes will perform liveness checks on mon, mds and osd daemons.
The command will:
* call the socket (check for existence)
* execute a command and check the return code (success if 0)
This handles the case where the daemon is stuck locally and
unresponsive. It's unlikely but not impossible.
These checks bring more robustness to the implementation.
rbd-mirror and nfs have been leftover for the following reason. The
rbd-mirror socket name is different from other daemons (could be fixed
though): /run/ceph/ceph-client.rbd-mirror.a.1.94362516231272.asok also,
the command to call would need to be changed from "status" to "rbd
mirror status" so we can keep this for a later.
The nfs ganesha has no socket only a PID file which doesn't mean much.
No PID means the process does not run so Kubernetes will already handle
this and the pod will crash loop.
Signed-off-by: Sébastien Han <seb@redhat.com>
The pools had some legacy structs that translated between the
ceph.v1 types used by the CRDs and the internal implementation
of the pools. This simplifies the pool implementation by removing
the intermediate model and leaving us only with the ceph v1
pool types and no unnecessary translation.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
They are cases where we let the exponential backoff retry and some where
we force our own retry. Let's properly log this information.
Signed-off-by: Sébastien Han <seb@redhat.com>
Let's not wait for the CephCluster to be done reconciling but instead
check for the Ceph cluster status, if it's closed to "ok" then we
proceed so HEALTH_OK and HEALTH_WARN are accepted.
Signed-off-by: Sébastien Han <seb@redhat.com>
This is critical to get this information so that the label can be set
properly and also the configuration done appropriately.
Signed-off-by: Sébastien Han <seb@redhat.com>
The CRD watcher has been replaced by the new controller-runtime
framework.
This brings robustness in our operator, meaning that any resources that
are modified will be reconciled into the desired state.
Closes: https://github.com/rook/rook/issues/4940
Signed-off-by: Sébastien Han <seb@redhat.com>
The helpers for executing a process have long required an actionName
param which is not being used. Now we remove the old param
while also cleaning up various other usages of the exec
package.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
As part of the transition to support Ceph release **as of** Nautilus, we
left over that portion of code.
We don't need it anymore.
Signed-off-by: Sébastien Han <seb@redhat.com>
Now, the CephBlockPool CRD is managed with the controller-runtime.
So the watcher is outside of the main controller reconciliation loop of
CephCluster which brings numerous benefit such as:
* having its own reconciliation loop
* won't block anything from the main CephCluster controller loop
* fast than waiting for CephCluster loop to completion
Partially close: https://github.com/rook/rook/issues/1981
Signed-off-by: Sébastien Han <seb@redhat.com>
As of Octopus, Ceph will prevent you from creating a pool with a
replica size of 1. Allowing such pool could lead to data loss, so enable
the new option: requireSafeReplicaSize: false if you are **ABSOLUTELY**
certain that is what you want.
Closes: https://github.com/rook/rook/issues/4889
Signed-off-by: Sébastien Han <seb@redhat.com>
This commit is to handle all those unhandled errors which raises the gosec warning.
Fixed G104: Unhandled Errors are handled now
Signed-off-by: Nizamudeen <nia@redhat.com>
When the cluster is upgraded, the child controllers are notified with the
callback to the ParentClusterChanged() method. These should be made
in a separate goroutine so that the cluster controller is not blocked
on the child controllers and also so child controllers aren't blocked
on each other for the upgrade.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
We now always perform ok-to-stop change when the deployment is going to
be updated. This could be for various reasons like change in the spec or
a new Ceph image.
In any case, if Ceph resources are going to be restarted this must be
done carefully.
Also trimmed the isUpgrade variable, the upcoming commit will remove the
need of that variable.
Keeping isUpgrade from the controller code since we need it to detect
whether an orchestration upgrade should be triggered or not (based on
the ceph cluster status).
Also, we keep it on the child controllers so we don't go into an
orchestration phase if the cluster image hasn't changed. The child does
not need to be updated/go into its orchestration phase because the
cluster CR changed.
Closes: https://github.com/rook/rook/issues/4379
Signed-off-by: Sébastien Han <seb@redhat.com>
We now force the mds daemon to join the fs that was created by Rook.
This can always be changed by using the ceph config store.
Closes: https://github.com/rook/rook/issues/4707
Signed-off-by: Sébastien Han <seb@redhat.com>
With this modification is guaranteed that at least 1 MDS pod is going to be
placed in each of the available zones in the k8s cluster.
This would be improved in the future using:
<Pod Topology Spread Constraints> (still in alpha state since kubernetes V.1.16)
This modification obtain the number of zones in the k8s cluster and appends an
<antiaffinity> term using the topologyKey
<topology.kubernetes.io/zone> in the same number of MDS pods.
In the case that will be more MDS pods than zones, the <antiaffinity> term won't
be added in these extra pods.
Important Note:
The antiaffiniy term only will work with nodes labeled using the NEW label:
<topology.kubernetes.io/zone> present in k8s V.1.17 clusters.
For previous versions of k8s clusters the label used is:
<failure-domain.beta.kubernetes.io/zone>
And therefore, in this kind of clusters this modification won't work.
Resolves#4641
[test ceph]
Signed-off-by: Juan Miguel Olmo Martínez <jolmomar@redhat.com>
A new CRD option `continueUpgradeAfterChecksEvenIfNotHealthy` is added.
When upgrading, Rook goes OSD by OSD and then waits for PGs to be clean
before proceeding to the next OSD. Currently, Rook waits for 5 hours but
there might be circumstances where PGs need more time to settle.
Thus setting `continueUpgradeAfterChecksEvenIfNotHealthy` to true will
pursue the upgrade process, even if PGs are not 100% active+clean.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1786029
Signed-off-by: Sébastien Han <seb@redhat.com>
The operator kit had more utility originally when the operator
was creating and managing the TPRs and CRDs directly. Since
the CRDs are now created from a manifest and no longer by the
operators, the utility of operator kit is limited to the
controller watcher. Since we are moving to the controller runtime
we simplify the code to make the transition smoother. Now
there is only a simple WatchCR method that will need to be
replaced as we maek that transition.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
This commit adds status field for ceph related CRs which will be useful for knowing the ceph component status without checking the logs.
Signed-off-by: Ashish Ranjan <ashishranjan738@gmail.com>
Reduce from 5 minutes to less than 50 seconds the time needed to restart a
mgr and osds(PVCs based),rgw,mds,rbd,nfs and toolbox pod that was running
in a k8s "NotReady" Node.
A new Rook Operator setting has been added to allow the user to set the
time used in pod's toleration <node.kubernetes.io/unreachable>:
ROOK_UNREACHABLE_NODE_TOLERATION_SECONDS = <5>
New setting added in release notes
Addressed @travisn,@leseb, and @blaineEXE suggestions
Signed-off-by: Juan Miguel Olmo Martínez <jolmomar@redhat.com>
When using the "errors" package, using `%+v` (extended format),
each Frame of the error's StackTrace will be printed in detail.
Let's only print `%v` to print the error.
If the error has a Cause it will be printed recursively.
Basically `%+v` has been replaced with `%v` for all `error` type
interfaces, whether the logger is Info, Warning or Error.
Signed-off-by: Sébastien Han <seb@redhat.com>
We recently discovered a race condition which happens not to update the
child CRDs when CR image changes.
The race happens under the following sequence:
* orchestration onAdd() is called when the operator image restarts
or its image updated
* the orchestration then goes into processing mon/mgr/osd
* during this the cluster CR is updated so onUpdate() is called,
however, onAdd() is not done yet for child CRDs (mds, rgw)
* onUpdate() runs against the cluster CR and updates the cluster images
* by the time the child CRDs reached onUpdate() from their respective
ParentClusterChanged() methods, the image is already up to date
so we were exiting since our check for updating
these resources are based on the cluster image version
To fix this, we changed the comparison, but using isUpgrade instead and
slightly changed the way isUpgrade operates. So now, isUpgrade is true
even if the Ceph version is identical which allows us to verify whether
or not the image changed.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1775624
Signed-off-by: Sébastien Han <seb@redhat.com>
The Ceph Mimic release introduced the monitor config store which allows
us to set configuration flag per daemon in a centralized fashion. Let's
use it for Mimic and newer and keep the CLI flag of daemon startup for
older versions.
The main benefit is that the config of a daemon can now be overridden.
Also, this commit refactors some code and add methods that are unit
tested.
Closes: https://github.com/rook/rook/issues/4307
Signed-off-by: Sébastien Han <seb@redhat.com>
Checking for isUpgrade is irrelevant since we need to restart the
deployment because the the spec has changed, the only thing that might
change is whether or not we perform upgrade checks.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1775624
Signed-off-by: Sébastien Han <seb@redhat.com>
This change standardizes the ownerRefs of Ceph keyrings to
k8s Deployment resources across all daemons and refactors a
bit of duplicate code on keyring association for ease of
maintenance.
Fixes: #4089
Signed-off-by: egafford <egafford@redhat.com>
Failure to create a keyring prior to creating a deployment
dependent on that keyring created a race conditition resulting
in an intermittent and unnecessary pod failure. This change
creates a keyring prior to deployment creation for MDS
daemons.
Partially fixes: rook#4089
Signed-off-by: egafford <egafford@redhat.com>