This change addresses a permission issue where mon pods crashloop
on some Kubernetes setups with SELinux enabled, even when
ROOK_HOSTPATH_REQUIRES_PRIVILEGED is set.
To resolve this, a new function makeMonSecurityContext() was introduced
to explicitly set runAsUser: 0 at the pod level for mon pods
when the environment variable ROOK_CEPH_MON_RUN_AS_ROOT is set to true.
Additionally, the function previously named PodSecurityContext() was renamed
to DefaultContainerSecurityContext() to avoid confusion between
container-level and pod-level security context configuration. All container
SecurityContext usages across Ceph daemons were updated to reflect this change.
This ensures the root user configuration is applied
automatically and consistently in environments where it is required
for mon pod startup, while preserving clear separation of container
and pod-level security logic.
Signed-off-by: Patryk Rostkowski <patrostkowski@gmail.com>
Resolves CIS benchmark rule 5.7.3, Pods part. SecurityContext
should be explicitly defined in pod level of Pod spec section.
It is sufficient to specify empty securityContext to satisfy
CIS 5.7.3 rule.
5.7.3 Apply Security Context to Your Pods and Containers
When designing your containers and pods, make sure
that you configure the security context for your pods,
containers, and volumes.
Signed-off-by: Peter Razumovsky <prazumovsky@mirantis.com>
This adds an operator config setting ROOK_REVISION_HISTORY_LIMIT
defaulting to kubernetes'value for RevisionHistoryLimit.
If configured, the provided value will be used as RevisionHistoryLimit
for all Deployments rook creates.
Fixes: #12722
Signed-off-by: Michael Adam <obnox@samba.org>
Change how Rook detects network CIDRs for Multus networks. The IPAM
configuration is only defined as an arbitrary string JSON blob with a
"type" field and nothing more. Rook's detection of CIDRs for whereabouts
had already grown out of date since the initial implementation.
Additionally, Rook did not support DHCP IPAM, which is a reasonable
choice for users. And more, Rook did not support CNI plugin chaining,
which further complicates NADs. Based on the CNI spec, network chaning
can result in any changes to network CIDRs from the first-given plugin.
All these problems make it more and more difficult for Rook to support
Multus by inspecting the NAD itself to predict network CIDRs. Instead,
it is better for Rook to treat the CNI process as a black box. To
preserve legacy functionality of auto-detecting networks and to make
that as robust as possible, change to a canary-style architecture like
that used for Ceph mons, from which Rook will detect the network CIDRs
if possible.
Also allow users to specify overrides for CIDR ranges. This allows Rook
to still support esoteric and unexpected NAD or network configurations
where a CIDR range is not detectable or where the range detected would
be incomplete. Because it may be impossible for Rook to understand the
network CIDRs wholistically while residing only on a portion of the
network, this feature should have been present from Multus's inception.
Improving CIDR auto-detection and allowing users to specify overrides
for auto-detected CIDRs rounds out Rook's Multus support for CephCluster
(core/RADOS) installations. No further architectural changes should be
needed for CephClusters as regards application of public/cluster network
CIDRs for Multus networks.
Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
We need to restart all the ceph daemons whenever
cephCluster network settings are modified like
requiremsgr2, encryption and compression. This
required for Ceph to consider the new settings
it require new ceph daemons all over.
Signed-off-by: subhamkrai <srai@redhat.com>
Introduce a new env variable ROOK_CSI_IMAGE_PULL_POLICY in rook operator configmap which should be used to
customize the imagePullPolicy for the csi driver and imagePullPolicy property in cephVersionSpec for ceph pods.
Signed-off-by: Avan Thakkar <athakkar@redhat.com>
Adding Recommended Labels on the resources created by rook
and using Recommended Labels in the helm chart,
for better visuals and management of k8s object
Closes: https://github.com/rook/rook/issues/8400
Signed-off-by: parth-gr <paarora@redhat.com>
The rook.io/v1 package was only an internal implementation detail and
does not have any CRDs that rely on it. The CRD deserialization should
handle the change in internal types without any issue. This separation
gives more flexibility for the storage providers to implement exactly
what is needed for their storage provider instead of forcing to use the
same types and risk affecting another storage provider.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
When a private docker registry is used and an image pull secret is specified in the chart, the pods with default Service Account fail to pull the image due to authentication issues.
Added rook-ceph-default service account and modify the pods specifications by adding the serviceAccountName.
Closes: https://github.com/rook/rook/issues/6673
Co-authored-by: Tareq Sharafy <tareq.sha@gmail.com>
Signed-off-by: parth-gr <partharora1010@gmail.com>
In the case of PVC,
We are giving lower priority to all placement.
We want deviceSet placement to applied and
override in case of overlapping settings and
we are merging nodeAffinity if applied in both
all placement and deviceSet.
In case of non-PVC,
we apply spec.placement
Signed-off-by: subhamkrai <srai@redhat.com>
Co-authored-by: Travis Nielsen <tnielsen@redhat.com>
It's better to validate ownerReferences when setting them. In addition, we should use
controllerrutil.Set{Controller,Owner}Reference, that have such validation, as possible.
Signed-off-by: Satoru Takeuchi <satoru.takeuchi@gmail.com>
When deploying the ceph-fs-mirror daemon we don't need to name the
deployment like "rook-ceph-fs-mirror-a", we can simply go with
"rook-ceph-fs-mirror". Today, in Pacific, the daemon only supports a
single replica. In the future, the Ceph Quincy release should support
mulitiple concurrent daemons, at this point Rook will introduce a
"count" field in the CephFilesystemMirror CRD specification. Internally,
this field will map with the "replica" value of the Deployment.
Signed-off-by: Sébastien Han <seb@redhat.com>
we don't want to merge the node affinity if specified in both
storageClassDeviceSet and placement. Now, we are passing new
boolean argument in `ApplyToPodSpec` which will be false in
case of osd and prepare pods because we don't want to overlap
placement of osd on PVC's and non-PVC's.
Signed-off-by: subhamkrai <srai@redhat.com>
With Ceph Pacific, Rook can now deploy the cephfs-mirror daemon.
This initial commit covers the deployment of a single daemon only.
Multiple mirror daemons is currently untested.
Only a single mirror daemon is recommended.
The configuration of peers will come in a later PR since the mgr module
is still pending upstream: https://github.com/ceph/ceph/pull/39050
The same goes for integration tests, they will get added later once we
start testing on Pacific.
Closes: https://github.com/rook/rook/issues/7002
Signed-off-by: Sébastien Han <seb@redhat.com>