in endpoint slice for the mgr and rgw service
it was harcoded to use the ipv4,
now dynamically assign the type based on the endpoint
ip adrress type
Signed-off-by: parth-gr <partharora1010@gmail.com>
Change how Rook detects network CIDRs for Multus networks. The IPAM
configuration is only defined as an arbitrary string JSON blob with a
"type" field and nothing more. Rook's detection of CIDRs for whereabouts
had already grown out of date since the initial implementation.
Additionally, Rook did not support DHCP IPAM, which is a reasonable
choice for users. And more, Rook did not support CNI plugin chaining,
which further complicates NADs. Based on the CNI spec, network chaning
can result in any changes to network CIDRs from the first-given plugin.
All these problems make it more and more difficult for Rook to support
Multus by inspecting the NAD itself to predict network CIDRs. Instead,
it is better for Rook to treat the CNI process as a black box. To
preserve legacy functionality of auto-detecting networks and to make
that as robust as possible, change to a canary-style architecture like
that used for Ceph mons, from which Rook will detect the network CIDRs
if possible.
Also allow users to specify overrides for CIDR ranges. This allows Rook
to still support esoteric and unexpected NAD or network configurations
where a CIDR range is not detectable or where the range detected would
be incomplete. Because it may be impossible for Rook to understand the
network CIDRs wholistically while residing only on a portion of the
network, this feature should have been present from Multus's inception.
Improving CIDR auto-detection and allowing users to specify overrides
for auto-detected CIDRs rounds out Rook's Multus support for CephCluster
(core/RADOS) installations. No further architectural changes should be
needed for CephClusters as regards application of public/cluster network
CIDRs for Multus networks.
Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
The flex driver has been fully deprecated and thus removed from Rook.
Before upgrading to v1.8, users will need to convert existing flex volumes
from flex to csi volumes.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
In pkg/operator/k8sutil/network.go:ApplyMultus(), be more explicit about
the intended behavior in both var names, code comments, and unit tests.
Additionally fix a logic bug that could cause errors in the future if
more "cluster network apps" are identified in the future.
Signed-off-by: Blaine Gardner <blaine.gardner@redhat.com>
In pkg/operator/k8sutil/network.go:ApplyMultus(), sort the string
annotations before applying them so that Rook will avoid the situation
where a Deployment or Pod will need updated repeatedly even when no
Multus network configuration has changed.
Signed-off-by: Blaine Gardner <blaine.gardner@redhat.com>
The rook.io/v1 package was only an internal implementation detail and
does not have any CRDs that rely on it. The CRD deserialization should
handle the change in internal types without any issue. This separation
gives more flexibility for the storage providers to implement exactly
what is needed for their storage provider instead of forcing to use the
same types and risk affecting another storage provider.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
With this change, the Rook ceph cluster can have only a public network or
only a cluster network or both can be specified. Prior to this commit if
only a public network was specified, it was copied to the cluster network.
Signed-off-by: rohan47 <rohgupta@redhat.com>
In the whereabouts config, the network range is determined by range
option unlike other cni plugins that use Subnet option.
Signed-off-by: rohan47 <rohgupta@redhat.com>
You can now use Rook along with Multus. Multus must be up and running
and the right ressources must exist such as NetworkAttachmentDefinition
CR.
The Cluster CR spec has new fields to work with multus:
network:
provider: multus (or 'host' for hostNetworking)
selectors:
public: NetworkAttachmentDefinition name
cluster: NetworkAttachmentDefinition name
If only a single NetworkAttachmentDefinition is provided Rook will use
both anyway for the Ceph traffic.
Please refer to the doc to learn more.
Closes: https://github.com/rook/rook/issues/4716
Signed-off-by: Sébastien Han <seb@redhat.com>
The rook types used across the storage providers moved from the v1alpha2
package to the v1 package. This commit points the packages at their new
location. Implementation is expected to remain unchanged.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>