few functions got change as they were deprecated
for ex: ioutil.Readfile change to os.Readfile
ioutil.TempFile change to os.CreateTemp
And fixed golang-ci-lint-issues
Signed-off-by: parth-gr <paarora@redhat.com>
This commit anabled nfs csi ci and
add fixes/improvements to it like the
following:
- verify deletion of cephnfs and .nfs pool before proceeding
- verify pv deletion
- do not enable rook module
- reduce activeCount to 1 to save resources
- run cephnfs ci before cephfs ci since it cephfs
ci is more resource intensive.
Signed-off-by: Rakshith R <rar@redhat.com>
Rook will support the most recent seven K8s releases,
so we update the min version to 1.19 for Rook v1.10.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
The latest go modules come with a sync mutex that requires
us to pass the test suite by reference for proper use
of the mutex.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
The file deletion status has been intermittently failing for several
months. Investigation shows that the timeout is just missing by
a few seconds. Now we increase the timeout from 15 to 45 seconds
to stabilize the test.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
Block deletion of CephFilesystems when there are any raw Ceph
subvolumegroups present that have subvolumes in them. Empty
subvolumegroups will not block deletion.
One important subvolume group is "csi" which is the default location
where CSI subvolumes are kept. If this group is empty, it means that
there are no PVCs created based on the CephFilesystem in question. This
also holds true if there are external consumers of the filesystem in
external cluster mode.
Similarly, if there are any subvolumegroups (for example "_nogroup",
which includes subvolumes in the filesystem root) that contain
manually-created subvolumes, Rook will also see this and block deletion.
This comes into play currently with manually-created NFS exports.
A work-in progress aims to create a Ceph-CSI NFS export provisioner
which will likely create subvolumes in the "csi" group as well. This
implementation will catch this case also.
Rook still checks for CephFilesystemSubVolumeGroups explicitly in
addition to the check added here. This is to ensure that even empty
groups will block deletion if they are created via this CR type.
Signed-off-by: Blaine Gardner <blaine.gardner@redhat.com>
This removes double package imports. Example:
```
"github.com/rook/rook/pkg/apis/ceph.rook.io/v1"
cephv1 "github.com/rook/rook/pkg/apis/ceph.rook.io/v1"
```
Only one is now being used as shown in go-staticcheck ST1019
Signed-off-by: Alexander Trost <galexrt@googlemail.com>
cleanup the CRD and controller in defer
to make sure the CRD and controller are
removed as filesystem/block test also
install CRD and controller separately.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
The built-in pools device_health_metrics and .nfs created by ceph
need to be configured for replicas, failure domain, etc.
To support this, we allow the pool to be created as a CR.
Since K8s does not support underscores in the resource names
the operator must translate this special pool name into
the name expected by ceph.
This also sets the basis for allowing filesystem data
pools to specify the desired pool name instead of requiring
a generated name.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
The flex driver has been fully deprecated and thus removed from Rook.
Before upgrading to v1.8, users will need to convert existing flex volumes
from flex to csi volumes.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
The MDS core team suggested with deploy the MDS daemon first and then do
the filesystem creation and configuration. Reversing the sequence lets
us avoid spurious FS_DOWN warnings when creating the filesystem.
Closes: #8745
Signed-off-by: Sébastien Han <seb@redhat.com>
With v1.7 approaching, the upgrade integration test will now test from
v1.6.x to the latest master, which will effectively become the v1.7
release soon.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
When the CephCluster is configured with Multus and multiple networks are
used to deploy Ceph some commands are failing to be executed from the
Operator. These commands, in particular, `radosgw-admin` ones need access
to the "ceph public network" to talk to OSDs. Unfortunately, the
Rook-Ceph Operator does not have the network annotations and thus
doesn't have the networks available and cannot reach OSDs. So the commands end
up hanging and eventually time out.
Applying the annotations to the Operator pod is possible but will result
in restarting the operator too and this should be avoided at all costs.
Also, applying the annotations beforehand is not possible since the
Multus declaration is in the CephCluster specification. So we would have
no idea what to do.
So the current approach runs a new sidecar container in the mgr pod to
act as a proxy for "some" ceph commands, only the `radosgw-admin` ones
for multi-site setup. This is a small container with admin access
running idle waiting for commands to be executed. In a sense, it is
similar to the toolbox but we didn't want to clearly expose it, so
running as a sidecar is quite nice.
Proxying command is obviously not always recommended since we add an
extra hop in the network path. Now each request has to go from the
operator pod to the API server to the remote pod to Ceph. Previously,
the command only goes from the operator to Ceph.
It's worth noting that external mode is not impacted since no rgw pod
is configured. This scenario is flexible and allows us to scale
pretty well since any CephCluster with Multus will see its mgr sidecar
deployed and can then talk to Ceph. We are not limited.
Signed-off-by: Sébastien Han <seb@redhat.com>
The integration tests have long been painful to maintain with
settings in various places and copied to multiple types,
inconsistent variable names, and otherwise difficult to maintain
code. Now the settings for a test suite are all in one place and
they remain in the same settings type throughout the test.
The multi-cluster suite is also refactored to use the same install
and uninstall helpers as the other suites.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
Due to #6492, preservePoolsOnDelete is not useful at all for CephFS;
after the filesystem is deleted, the leftover pools cannot be
reassocaited with a newly created filesystem without wiping all
metadata. The only way we can actually preserve data is keeping around
the entire filesystem.
This commit implements a `preserveFilesystemOnDelete` option which work
similar to the existing pool preservation option but instead keeps the
whole CephFS while taking it down and removing all MDSes.
This commit also changes all documentation to refer to this new option
with the intent of essentially deprecating `preservePoolsOnDelete`. IMO,
keeping around `preservePoolsOnDelete` is actively harmful because it
lulls users into thinking their data will be safe but, in reality,
recovering from this situation is highly complex and has large potential
for data loss.
Signed-off-by: Lalit Maganti <lalitm@google.com>
golangci-lint linter gosec showing more errors
than gosec gh. This commit resolve
new errors. And, removing
nosec comments from autogenerated files.
Signed-off-by: subhamkrai <srai@redhat.com>
this commit will add error not found condition
check before assert delete on PVC and
statefulset due to whch flex test was failing.
Signed-off-by: subhamkrai <srai@redhat.com>
this commit handle golangci-lint linter errcheck.
`errcheck` - Errcheck is a program for checking for
unchecked errors in go programs. These unchecked errors
can be critical bugs in some cases
To see only staticcheck linter output
`golangci-lint run --disable-all -E errcheck`
Signed-off-by: subhamkrai <srai@redhat.com>
Added E2E testing to create,delete and restore
a snapshot, create a pvc-pvc clone, install
and uninstall snapshot controller and snapshot
CRD.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
This replaces any uses of `rbac.authorization.k8s.io/v1beta1` with
`rbac.authorization.k8s.io/v1` affecting RBAC objects like ClusterRole
and ClusterRoleBindings, etc. to make it consistent.
This is done as some RBAC objects used the `v1beta1` and others already
using `v1`.
Signed-off-by: Alexander Trost <galexrt@googlemail.com>
To provide more context for executing commands in a ceph cluster,
the full clusterInfo is now passed to the ceph execution commands.
All information about the cluster will now be available throughout
all the areas of the operator. The namespace, ceph credentials,
mon endpoints, and other info is a core part of that cluster info.
Arguments passed through the controllers are also simplified for
mons, mgr, osds, and other daemons where the parameters had
become too complex.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
Currently, we need to configure the Ceph external Admin keyi
in the Rook deployment to be able to connect to an external Ceph cluster.
If we wanted to run in a multi-tenant fashion
were several K8s/Rook clusters wanted to connect to the same external ceph cluster,
each K8s deployment would have the access to the External Ceph Admin key
and could potentially access or delete the Data
from pools that belong to other k8s/Rook Clusters.
Now the admin key is optional but the helper script create-external-cluster-resources.sh
will help create the necessary keys/users to connect to that cluster.
Closes: https://github.com/rook/rook/issues/4917 and https://github.com/rook/rook/pull/5227
Signed-off-by: Sébastien Han <seb@redhat.com>
On Octopus, the "ceph fs status" reports on stderr for some reason.
So we need to combined the output to read the filesystem status.
Signed-off-by: Sébastien Han <seb@redhat.com>
The upgrade test requires the CSI driver to be running so we cannot
run the test on older versions than k8s 1.13.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
(cherry picked from commit f90664209b)
The integration tests have been mostly running on the flex driver
with only a newer test on the csi driver. With the CSI driver being
the preferred driver going forward, now the integration tests will
all be running with the CSI driver with the exception of a test
suite that is only dedicated to the flex driver.
A number of other test improvements are also made for code
readability, test stability, and removing unused options.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
The file-test consumer pod intermittently fails to stop during the
integration tests. When this happens, print the pod description
to see if there are events indicating the issue.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
The integration tests were always running two MDS daemons active,
with two standby. This is now parameterized so the test can request
how many MDS daemons to run. The smoke suite will run two active
and the rest will just run a single active MDS.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
The file-test pod still hangs sometimes when exiting. Instead of
trapping SIGTERM as before, use tini's `-g` option to kill the process
group. According to further reading on bash signal handling [1], Ctrl-C
sends a kill signal to the entire process group in order to kill `sleep`
commands.
[1] Link also noted in code comments:
http://mywiki.wooledge.org/SignalTrap#When_is_the_signal_handled.3F
Signed-off-by: Blaine Gardner <blaine.gardner@suse.com>
During upgrade tests, Rook should verify that it can still run legacy
OSDs. This includes directory-based OSDs, filestore disk OSDs, and
bluestore disk OSDs installed without ceph-volume (i.e., before mimic
v13.2.2) can still be run after upgrade.
This necessitates running the upgrade test twice; once with filestore
and once with bluestore.
Signed-off-by: Blaine Gardner <blaine.gardner@suse.com>
There are two separate integration tests for file. To simplify
and streamline and potentially eliminate some random failures,
these tests now consume the same file system instead of creating
a separate file system.
Signed-off-by: travisn <tnielsen@redhat.com>
The filesystem test deletes the client test pod by deleting the entire yaml
and sometimes hangs the integration tests. This is the most common intermittent
error in the CI. Now the deletion will happen more directly with a pod delete
command. If it does still fail deletion at least the deletion should timeout
sooner.
Signed-off-by: travisn <tnielsen@redhat.com>
Some integration tests fail due to resources from a previous integration
run not being cleaned up properly. Instead of using 'kubectl create' --
which fails with an error if the resource already exists -- to create
resources, use 'kubectl apply' -- which does not fail for pre-existing
resources. 'kubectl apply' will give a warning that it should be used to
apply changes to resources created with 'create' or 'apply', but there
is no error.
Signed-off-by: Blaine Gardner <blaine.gardner@suse.com>
With the storage providers growing, we should make it
clear in the source which tests belong to which storage
provider. This change renames the ceph integration tests.
Signed-off-by: travisn <tnielsen@redhat.com>