When deleting a CephObjectStoreUser the deleteUser function
attempts to delete the stored secret using the wrong name. This
patch updates deleteUser to use the same fmt.Sprintf call used in
the createUser function.
Updated CI to delete the correct CRD and check the secret is deleted.
Signed-off-by: Keith Schincke <keith.schincke@gmail.com>
Configure the Ceph rgw daemon completely from the operator a la the
recent changes to the Ceph mon, mgr, and mds operators.
Create the rgw deployment or daemonset first, and then create the
keyring secret for the object store with its owner reference as the
corresponding deployment or daemonset. When the replication controller
is deleted, the secret is also deleted.
The RGW's mime.types file is now stored in a configmap with a different
file created for each object store. This is primarily just a means to
get the mime.types file into the rgw pod, but the added benefit is that
the administrator can modify the configmap, which could reduce
susceptibility to file type execution vulnerabilities (worst case).
Signed-off-by: Blaine Gardner <blaine.gardner@suse.com>
Introduce mount security mode for basic multi tenancy
Fixes#2164.
This adds three new parameters/options to StorageClass/flexvolume entry:
* `mountUser`
* `mountSecret`
* `mountSecretNamespace`
Signed-off-by: Alexander Trost <galexrt@googlemail.com>
To help with code readability, include daemons from `pkg/daemon/ceph`
as `<dmn>daemon "github.com/rook/rook/pkg/daemon/ceph/<dmn>`. This will
make it easier to understand code lines without needing to scroll up to
check the includes, as there are mon/mds/mgr/osd/rgw packages for
daemons as well as operator and cmd.
Signed-off-by: Blaine Gardner <blaine.gardner@suse.com>
Fix some basic spellcheck errors. Also remove trailing spaces and make
sure files have a newline (my editor does automatically).
Signed-off-by: Blaine Gardner <blaine.gardner@suse.com>
- Add support for running individual test in a tests suite
- building integration and longhaul test binaries
- Addiing support for skipping CI or running just smoke test on a PR.