Commit Graph
13 Commits
Author SHA1 Message Date
Travis Nielsen 403335177a core: read mon secret from file instead of env var
Environment variables are not recommended for secrets in pods since
they can be easily leaked if the environemnt variables are logged.
By mounting the mon secret as a file, the mgr and osd prepare pods
can read the mon secret from a file for better security.

Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
2022-12-14 16:24:44 -07:00
Denis Egorenko fa2c276cc1 ceph: do not fail prepareOSD job if devices are not passed
If devices are not specified for node return empty desired devices
list and do not fail prepareOSD job.

Closes: #8097
Signed-off-by: Denis Egorenko <degorenko@mirantis.com>
2021-06-10 15:55:10 +04:00
Travis Nielsen 291bf9e061 ceph: enforce portable osds in same topology as osd prepare job
The osd prepare job detects the failure domain for the OSD by querying
the node topology labels. This topology is then assigned to the OSD
daemon in the CRUSH map. Previously, the affinity was required to be
set in the cluster CR, but it was very difficult to get right. Now the
operator will enforce the correct topology label on the OSD daemon
nodeAffinity by setting the label of the lowest topology in the hierarcy.

For example, if there are region, zone, and rack labels, the rack label
would be used to set the node affinity for the OSD daemon. If an
OSD prepare job is run in rack1, the corresponding OSD daemon will
have node affinity to rack1 to ensure the same topology. Previously,
the OSD could have ended up in rack2 unless the storageClassDeviceSet
placement was very carefully crafted.

Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
2021-02-18 12:49:37 -07:00
subhamkrai 829778f251 ceph: handle golangci-lint linter ineffassign
this commit will enable one more linter ineffassign
in golangci-lint.

This linter throws an error when variable is assigned and never used.

`golangci-lint run --disable-all -E ineffassign` is used detects ineffassign
errors only.

Signed-off-by: subhamkrai <subhamkumarrai03@gmail.com>
2020-09-21 14:31:18 +05:30
Blaine Gardner 825f1e3eb2 ceph: support device names with special chars
Pass desired devices to the OSD provisioning container by
JSON-marshalling/-unmarshalling a disk ID with StorageConfig settings.
This will allow disks to be specified that contain special characters.
Notably, this will support /dev/disk/by-path/pci-HHHH:HH:HH.H devices
that were unsupported previously due to the format which separated
devices from params with colons (:).

Fixes #5056
Fixes #5535

Signed-off-by: Blaine Gardner <blaine.gardner@suse.com>
2020-07-17 09:44:26 -06:00
n.fraison 7bac027796 ceph: ensure crush-location osd command args is always the same
Currently each time the ceph operator restart, osds also restart.
This is due to a change in the crush-location args with location not ordered
At each restart the location order can change and lead to that kind of change in the osd deployment
104c105
<                             "--crush-location=root=default host=hostname datacenter=PAR pod=2 rack=2",
---
>                             "--crush-location=root=default host=hostname pod=2 rack=2 datacenter=PAR",
Sorting the topology to ensure stability of this command arg

Signed-off-by: n.fraison <n.fraison@criteo.com>
2020-01-21 15:04:16 +01:00
Kazuhito MATSUDA 40d868ebd7 ceph: support device selection for OSDs by device path name patterns
Add devicePathFilter to Storage Selection Settings which enables
device selection with a regular expression for device path names.

Fixes: https://github.com/rook/rook/issues/4275
Signed-off-by: Kazuhito MATSUDA <kazuto.jinnai@gmail.com>
2019-12-05 07:02:44 +00:00
Rohan CJ 4d7c6df034 Ceph: Fix topologyAware in clusterdisruption package does not respect the rook topolgy prefix.
Allow the clusterdisruption package to recognize node topologies other than zone.

Signed-off-by: Rohan CJ <rohantmp@gmail.com>
2019-11-11 09:38:33 +05:30
Travis Nielsen 831c15086a ceph: support all layers of CRUSH map with node labels
The node labels were already supported for zones and regions to add to
the CRUSH map. Now all layers of the CRUSH map will be supported
with the new labels such as topology.rook.io/rack.
The labels will be detected at the osd startup time
similar to the zone and region labels already being detected.

Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
2019-10-31 14:47:18 -06:00
Michael Vollman ed9519953a ceph: add per OSD custom deviceClass support
Add deviceClass as a per OSD config option under
storage/nodes/devices/config for setting a custom crush device class
per OSD.

Signed-off-by: Michael Vollman <michael.b.vollman@gmail.com>
2019-08-29 20:39:41 -04:00
Michael Vollman 496c638306 ceph: add db-devices flag and fix DatabaseSizeMB
Adding support for the db-devices flag for ceph versions 14.2.1 and
newer.  This flag will allow for explictly setting the db device for
bluestore configurations to the device specified as metadataDevice.

Fixing the databaseSizeMB config parameter to ensure it is used to set
the size of the db-device partition when specified at either the global
or individual device level. (#3652)

Signed-off-by: Michael Vollman <michael.b.vollman@gmail.com>
2019-08-29 20:39:41 -04:00
Michael Vollman f3ef680298 ceph: Add support for per OSD metdataDevices
Add ceph-volume support for per OSD metdataDevices

Signed-off-by: Michael Vollman <michael.b.vollman@gmail.com>
2019-08-02 07:41:45 -04:00
travisn 1389cc56db ceph: enable multiple osds per device
Signed-off-by: travisn <tnielsen@redhat.com>
2018-12-07 09:29:15 -07:00