Commit Graph
20 Commits
Author SHA1 Message Date
Redouane Kachach 39c06d2fa5 mgr: adding logic to keep retrying in case mgr config delete fails
we dont set removeMgrDaemonConfiguration to true unless all the
delete operations went successfull.

Signed-off-by: Redouane Kachach <rkachach@redhat.com>
2024-01-25 21:55:13 +01:00
Alexander Trost 4ed35d6bd6 operator: allow setting ceph config options via ceph cluster crd
This implements the "Ceph Config via Ceph Cluster CRD" design document
as a `cephConfig:` structure on the CRD.
This also fixes the `yq` commands used to manipulate the
`cluster-test.yaml` that caused CI issues for this PR and potentially
unknowingly others.

Signed-off-by: Alexander Trost <galexrt@googlemail.com>
2023-12-02 00:05:48 +01:00
travisn 5359c4f4f5 mon: write assimilate config to operator dir
The /tmp dir is not always available in some environments.
The only directories the operator should rely on
are the directories that are in its pod spec.
For assimilate-conf now we use the /var/lib/rook
directory to generate files since we know it is
a valid emptydir mounted into the operator pod.

Signed-off-by: travisn <tnielsen@redhat.com>
2023-10-10 16:10:30 -06:00
Blaine Gardner 3c43268d0a multus: detect network CIDRs via canary
Change how Rook detects network CIDRs for Multus networks. The IPAM
configuration is only defined as an arbitrary string JSON blob with a
"type" field and nothing more. Rook's detection of CIDRs for whereabouts
had already grown out of date since the initial implementation.
Additionally, Rook did not support DHCP IPAM, which is a reasonable
choice for users. And more, Rook did not support CNI plugin chaining,
which further complicates NADs. Based on the CNI spec, network chaning
can result in any changes to network CIDRs from the first-given plugin.

All these problems make it more and more difficult for Rook to support
Multus by inspecting the NAD itself to predict network CIDRs. Instead,
it is better for Rook to treat the CNI process as a black box. To
preserve legacy functionality of auto-detecting networks and to make
that as robust as possible, change to a canary-style architecture like
that used for Ceph mons, from which Rook will detect the network CIDRs
if possible.

Also allow users to specify overrides for CIDR ranges. This allows Rook
to still support esoteric and unexpected NAD or network configurations
where a CIDR range is not detectable or where the range detected would
be incomplete. Because it may be impossible for Rook to understand the
network CIDRs wholistically while residing only on a portion of the
network, this feature should have been present from Multus's inception.

Improving CIDR auto-detection and allowing users to specify overrides
for auto-detected CIDRs rounds out Rook's Multus support for CephCluster
(core/RADOS) installations. No further architectural changes should be
needed for CephClusters as regards application of public/cluster network
CIDRs for Multus networks.

Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
2023-09-07 10:12:55 -06:00
Madhu Rajanna 1139cefc94 core: unset all encryption configuration before setting
if the configuration is already set in the ceph
database, using `ceph config assimilate-conf`
will add the key and value if its missing but
it wont update the value if the key is already
present, To fix this problem we can remove the
key and add all the configurations once again.

Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
2023-05-03 18:15:45 +02:00
Thomas Way ef60650f09 operator: log ceph error in monstore
Closes: #11795
Signed-off-by: Thomas Way <thomas@6f.io>
2023-03-20 17:44:01 +00:00
Travis Nielsen 1291885501 mon: use the assimilate mode for setall commands
The monstore has a SetAll method for applying multiple settings
that was applying them individually. Now we use the assimilate
config option to make this more efficient.

Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
2022-11-03 10:23:10 -06:00
Travis Nielsen 0514547d56 mon: refactor helper to assimilate mon store settings
More settings can use the assimilate command if refactored
to a different go package.

Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
2022-11-03 09:04:46 -06:00
Blaine Gardner 94b622c302 operator: set 'rook-version' in mon k/v store
Ceph upstream telemetry (which Rook users could optionally enable via
Ceph CLI or Dashboard) does not easily identify if a cluster is managed
by Rook. Identifying Rook clusters is possible only if users also enable
the rook mgr module, which is optional and not often used.

To get better upstream insights into Ceph clusters managed by Rook, set
a new 'rook-version' field in Ceph's generic k/v store. This field can
be used to determine if a cluster is managed by Rook by its presence.
It additionally provides information about the Rook version used to
manage the cluster, which is another piece of potentially useful
information.

Regarding Ceph cluster identification via telemetry:
Ceph telemetry is anonymous and uses a different ID from the Ceph
cluster ID. Identifying the Rook version in telemetry does not add
directly identifying information. Therefore, there should be little
risk that adding the Rook version field will decrease anonymity of Ceph
clusters via telemetry.

Signed-off-by: Blaine Gardner <blaine.gardner@redhat.com>
2022-05-12 09:31:13 -06:00
Sébastien Han 8da68bfb78 mon: run ceph commands to mon with timeout
If the mons are not in quorum yet the commands interacting with mon
config store will stale for a very long time.

Closes: https://github.com/rook/rook/issues/8928
Signed-off-by: Sébastien Han <seb@redhat.com>
2021-10-08 11:57:16 +02:00
Travis Nielsen cdfe1982d1 ceph: consolidate the calls to set mon config
The mon config had two different implementations that have evolved
over the lifetime of the project. This is a simple refactor to remove
the SetConfig() option and stick with the MonStore as a single
implementation for updating the mon store.

Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
2021-08-24 14:38:26 -06:00
Sébastien Han 19de2b28e9 ceph: allow heap dump generation when logCollector is not running
We don't need to set log_file to empty string since "log_to_file" is set
to False. This is probably an old leftover/hack we were doing in the
past when "log_to_file" and other related options were not there.

Because of this line
https://github.com/ceph/ceph/blob/master/src/perfglue/heap_profiler.cc#L99,
Ceph looks for the log_file conf option. In our case it was empty, so
the logging would default to the current directory which points to the
container runtime root when not set and we don't have permission to
write there.

We now force it to Ceph's default so that existing cluster will get the
fix after upgrading.

Just removing the option allows us to get dump in /var/log/ceph.
Phew, what a bug!

Signed-off-by: Sébastien Han <seb@redhat.com>
2021-05-10 17:21:04 +02:00
Travis Nielsen e74c7eaef8 ceph: refactor context and clusterInfo passed to the ceph commands
To provide more context for executing commands in a ceph cluster,
the full clusterInfo is now passed to the ceph execution commands.
All information about the cluster will now be available throughout
all the areas of the operator. The namespace, ceph credentials,
mon endpoints, and other info is a core part of that cluster info.

Arguments passed through the controllers are also simplified for
mons, mgr, osds, and other daemons where the parameters had
become too complex.

Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
2020-07-16 15:54:54 -06:00
n.fraison 6b9a70cb9a ceph: remove specific rgw configuration on mon configuration database
Remove specific rgw config added to the mon configuration database when deleting a CephObjectstore
or when scaling down number of rgw

Signed-off-by: n.fraison <n.fraison@criteo.com>
2020-04-21 22:36:11 +02:00
n.fraison ddadfbc993 ceph: remove leading and trailing space from get config
Value returned by ceph config get can contains some trailing space which leads to
issues when running other ceph command.
For ex.:
2020-04-06 15:32:43.543050 I | exec: Running command: ceph osd pool set test-1.rgw.control pg_num_min 8
 --connect-timeout=15 --cluster=rook-ceph --conf=/var/lib/rook/rook-ceph/rook-ceph.config --keyring=/var/lib/rook/rook-ceph/client.admin.keyring --format json --out-file /tmp/249563089
2020-04-06 15:32:44.005018 I | exec: Error EINVAL: error parsing int value '8

Signed-off-by: n.fraison <n.fraison@criteo.com>
2020-04-06 18:14:50 +02:00
Travis Nielsen e39637930d ceph: set pg_num for rgw metadata pools to lower default
The PG count on metadata pools should default to rgw_rados_pool_pg_num_min
instead of the more general default pg count. This means rgw pools
will default to 8 PGs instead of 32 PGs, which means a lot more pools
can be created before hitting the default PG limit.

Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
2020-03-27 09:06:59 -06:00
Sébastien Han ad95c7296f ceph: do not print extended format for loggers.
When using the "errors" package, using `%+v` (extended format),
each Frame of the error's StackTrace will be printed in detail.
Let's only print `%v` to print the error.
If the error has a Cause it will be printed recursively.

Basically `%+v` has been replaced with `%v` for all `error` type
interfaces, whether the logger is Info, Warning or Error.

Signed-off-by: Sébastien Han <seb@redhat.com>
2019-12-16 18:35:54 +01:00
Sébastien Han 5ce2ed220e ceph: use "github.com/pkg/errors"
We now use the error package.
Kubernetes errors have been renamed kerrors since they are lower than
'errors'.

Closes: https://github.com/rook/rook/issues/4054
Signed-off-by: Sébastien Han <seb@redhat.com>
2019-12-09 16:58:32 +01:00
Blaine Gardner 3a243d2978 ceph: remove configOverride functionality from CRD
After further consideration and working with the feature for a few
weeks, the `configOverride` functionality seems to be more complexity
than is worth it for the expected benefit. Users still have the most
preferred option of setting configs in Ceph's config database using
`ceph cofig set` or the dashboard, and the override ConfigMap still
exists for fallback scenarios. The config database can still be used
by Rook for setting necessary configs, but the user has no way of
telling Rook to do so.

Signed-off-by: Blaine Gardner <blaine.gardner@suse.com>
2019-09-05 12:30:56 -06:00
Blaine Gardner 1be43290be Ceph: override configs in CRD
Allow users to specify overrides in the CephCluster CRD. The override
ConfigMap still exists for emergency situations and is mounted into
daemon pods directly instead of being merged into a Rook-created config
file.

Rook Ceph no longer uses a config file for managing daemons with the
exception of the OSDs which still generate a config in an init
container.

Signed-off-by: Blaine Gardner <blaine.gardner@suse.com>
2019-08-29 15:38:27 -06:00