If the monitors addresses change, we must update the peer secret with
the new addresses. For this, each time the configmap
"rook-ceph-mon-endpoints" is updated, we trigger a reconcile on the
CephBlockPool CRs, which will update the token secret.
Signed-off-by: Sébastien Han <seb@redhat.com>
The rook.io/v1 package was only an internal implementation detail and
does not have any CRDs that rely on it. The CRD deserialization should
handle the change in internal types without any issue. This separation
gives more flexibility for the storage providers to implement exactly
what is needed for their storage provider instead of forcing to use the
same types and risk affecting another storage provider.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
With this change, the Rook ceph cluster can have only a public network or
only a cluster network or both can be specified. Prior to this commit if
only a public network was specified, it was copied to the cluster network.
Signed-off-by: rohan47 <rohgupta@redhat.com>
Events like node drain can take more than 10-15 minutes. If the node is not update the default monTimeOut of 10 minutes, then rook will attempt to fail over the mon. This failover won't work as the node is still down.
This PR retries once before the mon failover if the mon pod is not scheduled
Signed-off-by: Santosh Pillai <sapillai@redhat.com>
Update OSDs in parallel per the design in
design/ceph/update-osds-in-parallel.md
The max number of OSDs updated in parallel is currently fixed at 20.
Signed-off-by: Blaine Gardner <blaine.gardner@redhat.com>
In the case of PVC,
We are giving lower priority to all placement.
We want deviceSet placement to applied and
override in case of overlapping settings and
we are merging nodeAffinity if applied in both
all placement and deviceSet.
In case of non-PVC,
we apply spec.placement
Signed-off-by: subhamkrai <srai@redhat.com>
Co-authored-by: Travis Nielsen <tnielsen@redhat.com>
It's better to validate ownerReferences when setting them. In addition, we should use
controllerrutil.Set{Controller,Owner}Reference, that have such validation, as possible.
Signed-off-by: Satoru Takeuchi <satoru.takeuchi@gmail.com>
If there are multiple mgrs running, the operator will automatically
add pod antiaffinity across hosts by default. For stretch clusters,
antiaffinity across the stretch failure domain (e.g. zones)
will be added. Required antiaffinity will be created unless the
test setting allowMultiplePerNode is set to true.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
If there are two mgr daemons, they should be running on different
hosts or zones, depending on the failure domain.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
The mgr daemon may be failed over by ceph if the active mgr is not
responding and the standby mgr is available. If the active mgr changes
the services for the dashboard and metrics will be updated with a
label selector for the new active mgr. The services cannot direct
traffic to the standby mgr or else they will be incorrectly redirected
to the active mgr.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
Do not reconcile ServiceMonitor/PrometheusRule on label updates.
This allows users to add custom labels which can be used by
custom Prometheus instances for monitoring.
Signed-off-by: Umanga Chapagain <chapagainumanga@gmail.com>
Remove features and design that supports adding OSDs to Ceph clusters
via `spec:driveGroups`. Update the Ceph upgrade doc that informs users
who currently use Drive Groups (we believe there are none of these
users) how to migrate to using the `spec:storage` config.
Resolves https://github.com/rook/rook/issues/7275
Revert "ceph: fix drive group deployment failure"
This reverts commit 76f1d9944e.
Revert "ceph: osd: add drive groups spec to cluster CR"
This reverts commit 7117fc12b7.
Revert "design: ceph orchestrator module add/remove OSDs"
This reverts commit 178187d035.
Signed-off-by: Blaine Gardner <blaine.gardner@redhat.com>
The osd prepare job detects the failure domain for the OSD by querying
the node topology labels. This topology is then assigned to the OSD
daemon in the CRUSH map. Previously, the affinity was required to be
set in the cluster CR, but it was very difficult to get right. Now the
operator will enforce the correct topology label on the OSD daemon
nodeAffinity by setting the label of the lowest topology in the hierarcy.
For example, if there are region, zone, and rack labels, the rack label
would be used to set the node affinity for the OSD daemon. If an
OSD prepare job is run in rack1, the corresponding OSD daemon will
have node affinity to rack1 to ensure the same topology. Previously,
the OSD could have ended up in rack2 unless the storageClassDeviceSet
placement was very carefully crafted.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
we don't want to merge the node affinity if specified in both
storageClassDeviceSet and placement. Now, we are passing new
boolean argument in `ApplyToPodSpec` which will be false in
case of osd and prepare pods because we don't want to overlap
placement of osd on PVC's and non-PVC's.
Signed-off-by: subhamkrai <srai@redhat.com>
Do not force unit tests to be run while the rook repo is in the GOPATH.
Now that Rook uses go modules, this is no longer necessary. Allow this
by creating a helper function that unit tests can use that return the
on-host path to the `rook` project root.
Signed-off-by: Blaine Gardner <blaine.gardner@redhat.com>
when a node fails some pods remains in terminating while other manage to
be rescheduled on another node successfully.
this commit adds code to clean up all the Rook and CSI pods that are stuck in terminating
state on a failed node.
Signed-off-by: rohan47 <rohgupta@redhat.com>
added waitTimeoutForHealthyOSD in the cluster crd that defines the time (in minutes) the operator would wait before an OSD can be stopped for
upgrade. This PR also removes the ok-to-continue logic for osds as its already handled by ok-to-stop. The default value is 10 minutes.
Signed-off-by: Santosh Pillai <sapillai@redhat.com>
updating to latest Kubernetes version 1.20.0 fix
security issues. In the current version, it allows
for the token leak in logs when logLevel >= 9.
Signed-off-by: subhamkrai <srai@redhat.com>
Currently, mgr deployment has two overlapping environment variables, ROOK_POD_IP.
This causes kube-apiserver to create error logs
Signed-off-by: binoue <banji-inoue@cybozu.co.jp>
The arbiter can only be configured with the stretch cluster if the
CRUSH map is balanced and there are two zones in the CRUSH map.
After the OSDs are configured, we wait for all the OSD pods to be
running and that the CRUSH map is balanced. If it takes more than
two minutes, we fail the reconcile and try again. This is only done
the first time the stretch cluster is configured. In future reconciles
we first check if the stretch cluster is already enabled before
enabling it again.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
This adds the functionality to add custom pod labels to the CSI
components through the operator configuration way of env vars or config
map.
Resolves#6593
Signed-off-by: Alexander Trost <galexrt@googlemail.com>
If users want to restrict the nodes where Ceph daemons should exist,
it's better to make the placement of admission controller configurable
as other daemons.
Signed-off-by: Satoru Takeuchi <satoru.takeuchi@gmail.com>
Found by running the following command:
codespell -S .git,*.png,*.jpg -L \
aks,keyserver,atleast,dne,ser,ist,files\',ba,dum,iam,te -f -H
Signed-off-by: Mateusz Gozdek <mgozdekof@gmail.com>
Instead of directly defining our own constants, we should be using the k8s
constants for the well-known topology labels.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
In clusters where only two datacenters (or similar failure domains)
are available, a different mon and osd approach is needed to deal
with the network partitions or some other reason for one of the failure
domains going down. The Ceph stretched cluster makes the mons aware
of the failure domains by configuring one as the arbiter in a third
zone, while keeping two replicas of the data in each of the data
zoens.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
this commit handle golangci-lint linter errcheck.
`errcheck` - Errcheck is a program for checking for
unchecked errors in go programs. These unchecked errors
can be critical bugs in some cases
To see only staticcheck linter output
`golangci-lint run --disable-all -E errcheck`
Signed-off-by: subhamkrai <srai@redhat.com>
this commit handle golangci-lint linter staticcheck error.
`staticcheck` - Staticcheck is a go vet on steroids,
applying a ton of static analysis checks.
To see only `staticcheck` linter output
`golangci-lint run --disable-all -E staticcheck`
Signed-off-by: subhamkrai <srai@redhat.com>
this commit will enable one more linter ineffassign
in golangci-lint.
This linter throws an error when variable is assigned and never used.
`golangci-lint run --disable-all -E ineffassign` is used detects ineffassign
errors only.
Signed-off-by: subhamkrai <subhamkumarrai03@gmail.com>
If the pod spec changed, we expect an upgrade to proceed for that daemon.
If the check for a changed pod spec fails, we were skipping the update
of that daemon. Instead of skipping the update, we now assume the pod
spec changed if we fail to detect the change so that we can ensure the upgrade
even if we check for upgrades too often.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>