This is handling a tricky scenario where the OSD deployment is manually
removed and the OSD never reconvers. This is unlikely to happen, but
still OSD should be able to run after that action. Essentially after a
manual deletion, we need to run the prepare job again to re-hydrate the
OSD information so that the OSD deployment can be deployed.
On encryption, it is a little bit tricky since ceph-volume list again
the main block won't return anything, so we need to target the encrypted
block to list.
There is another case this PR does not handle, which is the removal of
the OSD deployment and then the node is restarted. This means that the
encrypted container is not opened anymore. However, opening it requires
more work like writing the key on the filesystem (if not coming from the
Kubernete secret, eg,. KMS vault) and then run luksOpen. This is an
extreme corner case probably not worth worrying about for now.
Signed-off-by: Sébastien Han <seb@redhat.com>
(cherry picked from commit 05775b068d)
1203 lines
42 KiB
Go
1203 lines
42 KiB
Go
/*
|
|
Copyright 2018 The Rook Authors. All rights reserved.
|
|
|
|
Licensed under the Apache License, Version 2.0 (the "License");
|
|
you may not use this file except in compliance with the License.
|
|
You may obtain a copy of the License at
|
|
|
|
http://www.apache.org/licenses/LICENSE-2.0
|
|
|
|
Unless required by applicable law or agreed to in writing, software
|
|
distributed under the License is distributed on an "AS IS" BASIS,
|
|
WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
|
See the License for the specific language governing permissions and
|
|
limitations under the License.
|
|
*/
|
|
|
|
package osd
|
|
|
|
import (
|
|
"bytes"
|
|
"encoding/json"
|
|
"fmt"
|
|
"io/ioutil"
|
|
"os"
|
|
"path"
|
|
"path/filepath"
|
|
"regexp"
|
|
"strconv"
|
|
"strings"
|
|
|
|
"github.com/pkg/errors"
|
|
"github.com/rook/rook/pkg/clusterd"
|
|
"github.com/rook/rook/pkg/daemon/ceph/client"
|
|
oposd "github.com/rook/rook/pkg/operator/ceph/cluster/osd"
|
|
cephver "github.com/rook/rook/pkg/operator/ceph/version"
|
|
"github.com/rook/rook/pkg/util/display"
|
|
"github.com/rook/rook/pkg/util/sys"
|
|
)
|
|
|
|
const (
|
|
osdsPerDeviceFlag = "--osds-per-device"
|
|
crushDeviceClassFlag = "--crush-device-class"
|
|
encryptedFlag = "--dmcrypt"
|
|
databaseSizeFlag = "--block-db-size"
|
|
dbDeviceFlag = "--db-devices"
|
|
cephVolumeCmd = "ceph-volume"
|
|
cephVolumeMinDBSize = 1024 // 1GB
|
|
)
|
|
|
|
// These are not constants because they are used by the tests
|
|
var (
|
|
cephConfigDir = "/var/lib/ceph"
|
|
cephLogDir = "/var/log/ceph"
|
|
lvmConfPath = "/etc/lvm/lvm.conf"
|
|
cvLogDir = ""
|
|
// The "ceph-volume raw" command is available since Ceph 14.2.8 as well as partition support in ceph-volume
|
|
cephVolumeRawModeMinCephVersion = cephver.CephVersion{Major: 15, Minor: 2, Extra: 0}
|
|
|
|
// The Ceph Octopus to include a retry to acquire device lock
|
|
cephFlockFixOctopusMinCephVersion = cephver.CephVersion{Major: 15, Minor: 2, Extra: 9}
|
|
isEncrypted = os.Getenv(oposd.EncryptedDeviceEnvVarName) == "true"
|
|
isOnPVC = os.Getenv(oposd.PVCBackedOSDVarName) == "true"
|
|
)
|
|
|
|
type osdInfoBlock struct {
|
|
CephFsid string `json:"ceph_fsid"`
|
|
Device string `json:"device"`
|
|
OsdID int `json:"osd_id"`
|
|
OsdUUID string `json:"osd_uuid"`
|
|
Type string `json:"type"`
|
|
}
|
|
|
|
type osdInfo struct {
|
|
Name string `json:"name"`
|
|
Path string `json:"path"`
|
|
Tags osdTags `json:"tags"`
|
|
// "block" for bluestore
|
|
Type string `json:"type"`
|
|
}
|
|
|
|
type osdTags struct {
|
|
OSDFSID string `json:"ceph.osd_fsid"`
|
|
Encrypted string `json:"ceph.encrypted"`
|
|
ClusterFSID string `json:"ceph.cluster_fsid"`
|
|
CrushDeviceClass string `json:"ceph.crush_device_class"`
|
|
}
|
|
|
|
type cephVolReport struct {
|
|
Changed bool `json:"changed"`
|
|
Vg cephVolVg `json:"vg"`
|
|
}
|
|
|
|
type cephVolVg struct {
|
|
Devices string `json:"devices"`
|
|
}
|
|
|
|
type cephVolReportV2 struct {
|
|
BlockDB string `json:"block_db"`
|
|
Encryption string `json:"encryption"`
|
|
Data string `json:"data"`
|
|
DatabaseSize string `json:"data_size"`
|
|
BlockDbSize string `json:"block_db_size"`
|
|
}
|
|
|
|
func isNewStyledLvmBatch(version cephver.CephVersion) bool {
|
|
if version.IsOctopus() && version.IsAtLeast(cephver.CephVersion{Major: 15, Minor: 2, Extra: 8}) {
|
|
return true
|
|
}
|
|
|
|
if version.IsAtLeastPacific() {
|
|
return true
|
|
}
|
|
|
|
return false
|
|
}
|
|
|
|
func (a *OsdAgent) configureCVDevices(context *clusterd.Context, devices *DeviceOsdMapping) ([]oposd.OSDInfo, error) {
|
|
var osds []oposd.OSDInfo
|
|
var lvmOsds []oposd.OSDInfo
|
|
var rawOsds []oposd.OSDInfo
|
|
var lvBackedPV bool
|
|
var block, lvPath, metadataBlock, walBlock string
|
|
var err error
|
|
|
|
// Idempotency check, if the device list is empty devices have been prepared already
|
|
// In this case, just return the OSDInfo via a 'ceph-volume lvm|raw list' call
|
|
if len(devices.Entries) == 0 {
|
|
logger.Info("no new devices to configure. returning devices already configured with ceph-volume.")
|
|
|
|
if a.pvcBacked {
|
|
// So many things changed and it's good to remember this commit and its logic
|
|
// See: https://github.com/rook/rook/commit/8ea693a74011c587970dfc28a3d9efe2ef329159
|
|
skipLVRelease := true
|
|
|
|
// For LV mode
|
|
lvPath = getDeviceLVPath(context, fmt.Sprintf("/mnt/%s", a.nodeName))
|
|
lvBackedPV, err := sys.IsLV(fmt.Sprintf("/mnt/%s", a.nodeName), context.Executor)
|
|
if err != nil {
|
|
return nil, errors.Wrap(err, "failed to check device type")
|
|
}
|
|
|
|
// List THE existing OSD configured with ceph-volume lvm mode
|
|
lvmOsds, err = GetCephVolumeLVMOSDs(context, a.clusterInfo, a.clusterInfo.FSID, lvPath, skipLVRelease, lvBackedPV)
|
|
if err != nil {
|
|
logger.Infof("failed to get device already provisioned by ceph-volume lvm. %v", err)
|
|
}
|
|
osds = append(osds, lvmOsds...)
|
|
if len(osds) > 0 {
|
|
// "ceph-volume raw list" lists the existing OSD even if it is configured with lvm mode, so escape here to avoid dupe.
|
|
return osds, nil
|
|
}
|
|
|
|
// List THE existing OSD configured with ceph-volume raw mode
|
|
if a.clusterInfo.CephVersion.IsAtLeast(cephVolumeRawModeMinCephVersion) {
|
|
// For block mode
|
|
block = fmt.Sprintf("/mnt/%s", a.nodeName)
|
|
|
|
// This is hard to determine a potential metadata device here
|
|
// Also, I don't think (leseb) this code we have run in this condition
|
|
// I tried several things:
|
|
// * evict a node, osd moves, the prepare job was never relaunched ever because we check for the osd deployment and skip the prepare
|
|
// * restarted the operator, again the prepare job was not re-run
|
|
//
|
|
// I'm leaving this code with an empty metadata device for now
|
|
metadataBlock, walBlock = "", ""
|
|
|
|
rawOsds, err = GetCephVolumeRawOSDs(context, a.clusterInfo, a.clusterInfo.FSID, block, metadataBlock, walBlock, lvBackedPV, false)
|
|
if err != nil {
|
|
logger.Infof("failed to get device already provisioned by ceph-volume raw. %v", err)
|
|
}
|
|
osds = append(osds, rawOsds...)
|
|
}
|
|
|
|
} else {
|
|
// Non-PVC case
|
|
// List existing OSD(s) configured with ceph-volume lvm mode
|
|
lvmOsds, err = GetCephVolumeLVMOSDs(context, a.clusterInfo, a.clusterInfo.FSID, lvPath, false, false)
|
|
if err != nil {
|
|
logger.Infof("failed to get devices already provisioned by ceph-volume. %v", err)
|
|
}
|
|
osds = append(osds, lvmOsds...)
|
|
|
|
// List existing OSD(s) configured with ceph-volume raw mode
|
|
rawOsds, err = GetCephVolumeRawOSDs(context, a.clusterInfo, a.clusterInfo.FSID, block, "", "", false, false)
|
|
if err != nil {
|
|
logger.Infof("failed to get device already provisioned by ceph-volume raw. %v", err)
|
|
}
|
|
osds = appendOSDInfo(osds, rawOsds)
|
|
}
|
|
|
|
return osds, nil
|
|
}
|
|
|
|
// Create OSD bootstrap keyring
|
|
err = createOSDBootstrapKeyring(context, a.clusterInfo, cephConfigDir)
|
|
if err != nil {
|
|
return nil, errors.Wrap(err, "failed to generate osd keyring")
|
|
}
|
|
|
|
// Check if the PVC is an LVM block device (certain StorageClass do this)
|
|
if a.pvcBacked {
|
|
for _, device := range devices.Entries {
|
|
dev := device.Config.Name
|
|
lvBackedPV, err = sys.IsLV(dev, context.Executor)
|
|
if err != nil {
|
|
return nil, errors.Wrap(err, "failed to check device type")
|
|
}
|
|
break
|
|
}
|
|
}
|
|
|
|
// Should we use ceph-volume raw mode?
|
|
useRawMode, err := a.useRawMode(context, a.pvcBacked)
|
|
if err != nil {
|
|
return nil, errors.Wrap(err, "failed to determine which ceph-volume mode to use")
|
|
}
|
|
|
|
// If not raw mode we must execute a few LVM prerequisites
|
|
if !useRawMode {
|
|
err = lvmPreReq(context, a.pvcBacked, lvBackedPV)
|
|
if err != nil {
|
|
return nil, errors.Wrap(err, "failed to run lvm prerequisites")
|
|
}
|
|
}
|
|
|
|
// If running on OSD on PVC
|
|
if a.pvcBacked {
|
|
if block, metadataBlock, walBlock, err = a.initializeBlockPVC(context, devices, lvBackedPV); err != nil {
|
|
return nil, errors.Wrap(err, "failed to initialize devices on PVC")
|
|
}
|
|
} else {
|
|
err := a.initializeDevices(context, devices, useRawMode)
|
|
if err != nil {
|
|
return nil, errors.Wrap(err, "failed to initialize osd")
|
|
}
|
|
}
|
|
|
|
// List OSD configured with ceph-volume lvm mode
|
|
lvmOsds, err = GetCephVolumeLVMOSDs(context, a.clusterInfo, a.clusterInfo.FSID, block, false, lvBackedPV)
|
|
if err != nil {
|
|
return nil, errors.Wrap(err, "failed to get devices already provisioned by ceph-volume lvm")
|
|
}
|
|
osds = append(osds, lvmOsds...)
|
|
|
|
// List THE configured OSD with ceph-volume raw mode
|
|
// When the block is encrypted we need to list against the encrypted device mapper
|
|
if !isEncrypted {
|
|
block = fmt.Sprintf("/mnt/%s", a.nodeName)
|
|
}
|
|
// List ALL OSDs when not running on PVC
|
|
if !a.pvcBacked {
|
|
block = ""
|
|
}
|
|
rawOsds, err = GetCephVolumeRawOSDs(context, a.clusterInfo, a.clusterInfo.FSID, block, metadataBlock, walBlock, lvBackedPV, false)
|
|
if err != nil {
|
|
return nil, errors.Wrap(err, "failed to get devices already provisioned by ceph-volume raw")
|
|
}
|
|
osds = appendOSDInfo(osds, rawOsds)
|
|
|
|
return osds, err
|
|
}
|
|
|
|
func (a *OsdAgent) initializeBlockPVC(context *clusterd.Context, devices *DeviceOsdMapping, lvBackedPV bool) (string, string, string, error) {
|
|
// we need to return the block if raw mode is used and the lv if lvm mode
|
|
baseCommand := "stdbuf"
|
|
var baseArgs []string
|
|
|
|
cephVolumeMode := "lvm"
|
|
if a.clusterInfo.CephVersion.IsAtLeast(cephVolumeRawModeMinCephVersion) {
|
|
cephVolumeMode = "raw"
|
|
} else if lvBackedPV {
|
|
return "", "", "", errors.New("OSD on LV-backed PVC requires new Ceph to use raw mode")
|
|
}
|
|
|
|
// Create a specific log directory so that each prepare command will have its own log
|
|
// Only do this if nothing is present so that we don't override existing logs
|
|
cvLogDir = path.Join(cephLogDir, a.nodeName)
|
|
err := os.MkdirAll(cvLogDir, 0750)
|
|
if err != nil {
|
|
logger.Errorf("failed to create ceph-volume log directory %q, continue with default %q. %v", cvLogDir, cephLogDir, err)
|
|
baseArgs = []string{"-oL", cephVolumeCmd, cephVolumeMode, "prepare", "--bluestore"}
|
|
} else {
|
|
// Always force Bluestore!
|
|
baseArgs = []string{"-oL", cephVolumeCmd, "--log-path", cvLogDir, cephVolumeMode, "prepare", "--bluestore"}
|
|
}
|
|
|
|
var metadataArg, walArg []string
|
|
var metadataDev, walDev bool
|
|
var blockPath, metadataBlockPath, walBlockPath string
|
|
|
|
// Problem: map is an unordered collection
|
|
// therefore the iteration order of a map is not guaranteed to be the same every time you iterate over it.
|
|
// So we could first get the metadata device and then the main block in a scenario where a metadata PVC is present
|
|
for name, device := range devices.Entries {
|
|
// If this is the metadata device there is nothing to do
|
|
// it'll be used in one of the iterations
|
|
if name == "metadata" || name == "wal" {
|
|
logger.Debugf("device %q is a metadata or wal device, skipping this iteration it will be used in the next one", device.Config.Name)
|
|
// Don't do this device
|
|
continue
|
|
}
|
|
|
|
// When running on PVC, the prepare job has a single OSD only so 1 disk
|
|
// However we can present a metadata device so we need to consume it
|
|
// This will make the devices.Entries larger than usual
|
|
if _, ok := devices.Entries["metadata"]; ok {
|
|
metadataDev = true
|
|
metadataArg = append(metadataArg, []string{"--block.db",
|
|
devices.Entries["metadata"].Config.Name,
|
|
}...)
|
|
|
|
metadataBlockPath = devices.Entries["metadata"].Config.Name
|
|
}
|
|
|
|
if _, ok := devices.Entries["wal"]; ok {
|
|
walDev = true
|
|
walArg = append(walArg, []string{"--block.wal",
|
|
devices.Entries["wal"].Config.Name,
|
|
}...)
|
|
|
|
walBlockPath = devices.Entries["wal"].Config.Name
|
|
}
|
|
|
|
if device.Data == -1 {
|
|
logger.Infof("configuring new device %q", device.Config.Name)
|
|
var err error
|
|
var deviceArg string
|
|
|
|
deviceArg = device.Config.Name
|
|
logger.Info("devlink names:")
|
|
for _, devlink := range device.PersistentDevicePaths {
|
|
logger.Info(devlink)
|
|
if strings.HasPrefix(devlink, "/dev/mapper") {
|
|
deviceArg = devlink
|
|
}
|
|
}
|
|
|
|
immediateExecuteArgs := append(baseArgs, []string{
|
|
"--data",
|
|
deviceArg,
|
|
}...)
|
|
|
|
crushDeviceClass := os.Getenv(oposd.CrushDeviceClassVarName)
|
|
if crushDeviceClass != "" {
|
|
immediateExecuteArgs = append(immediateExecuteArgs, []string{crushDeviceClassFlag, crushDeviceClass}...)
|
|
}
|
|
|
|
if isEncrypted {
|
|
immediateExecuteArgs = append(immediateExecuteArgs, encryptedFlag)
|
|
}
|
|
|
|
// Add the cli argument for the metadata device
|
|
if metadataDev {
|
|
immediateExecuteArgs = append(immediateExecuteArgs, metadataArg...)
|
|
}
|
|
|
|
// Add the cli argument for the wal device
|
|
if walDev {
|
|
immediateExecuteArgs = append(immediateExecuteArgs, walArg...)
|
|
}
|
|
|
|
// execute ceph-volume with the device
|
|
op, err := context.Executor.ExecuteCommandWithCombinedOutput(baseCommand, immediateExecuteArgs...)
|
|
if err != nil {
|
|
cvLogFilePath := path.Join(cvLogDir, "ceph-volume.log")
|
|
|
|
// Print c-v log before exiting
|
|
cvLog := readCVLogContent(cvLogFilePath)
|
|
if cvLog != "" {
|
|
logger.Errorf("%s", cvLog)
|
|
}
|
|
|
|
// Return failure
|
|
return "", "", "", errors.Wrapf(err, "failed to run ceph-volume. %s. debug logs below:\n%s", op, cvLog)
|
|
}
|
|
logger.Infof("%v", op)
|
|
// if raw mode is used or PV on LV, let's return the path of the device
|
|
if cephVolumeMode == "raw" && !isEncrypted {
|
|
blockPath = deviceArg
|
|
} else if cephVolumeMode == "raw" && isEncrypted {
|
|
blockPath = getEncryptedBlockPath(op, oposd.DmcryptBlockType)
|
|
if blockPath == "" {
|
|
return "", "", "", errors.New("failed to get encrypted block path from ceph-volume lvm prepare output")
|
|
}
|
|
if metadataDev {
|
|
metadataBlockPath = getEncryptedBlockPath(op, oposd.DmcryptMetadataType)
|
|
if metadataBlockPath == "" {
|
|
return "", "", "", errors.New("failed to get encrypted block.db path from ceph-volume lvm prepare output")
|
|
}
|
|
}
|
|
if walDev {
|
|
walBlockPath = getEncryptedBlockPath(op, oposd.DmcryptWalType)
|
|
if walBlockPath == "" {
|
|
return "", "", "", errors.New("failed to get encrypted block.wal path from ceph-volume lvm prepare output")
|
|
}
|
|
}
|
|
} else {
|
|
blockPath = getLVPath(op)
|
|
if blockPath == "" {
|
|
return "", "", "", errors.New("failed to get lv path from ceph-volume lvm prepare output")
|
|
}
|
|
}
|
|
} else {
|
|
logger.Infof("skipping device %q with osd %d already configured", device.Config.Name, device.Data)
|
|
}
|
|
}
|
|
|
|
return blockPath, metadataBlockPath, walBlockPath, nil
|
|
}
|
|
|
|
func getLVPath(op string) string {
|
|
tmp := sys.Grep(op, "Volume group")
|
|
vgtmp := strings.Split(tmp, "\"")
|
|
|
|
tmp = sys.Grep(op, "Logical volume")
|
|
lvtmp := strings.Split(tmp, "\"")
|
|
|
|
if len(vgtmp) >= 2 && len(lvtmp) >= 2 {
|
|
if sys.Grep(vgtmp[1], "ceph") != "" && sys.Grep(lvtmp[1], "osd-block") != "" {
|
|
return fmt.Sprintf("/dev/%s/%s", vgtmp[1], lvtmp[1])
|
|
}
|
|
}
|
|
return ""
|
|
}
|
|
|
|
func getEncryptedBlockPath(op, blockType string) string {
|
|
re := regexp.MustCompile("(?m)^.*luksOpen.*$")
|
|
matches := re.FindAllString(op, -1)
|
|
|
|
for _, line := range matches {
|
|
lineSlice := strings.Fields(line)
|
|
for _, word := range lineSlice {
|
|
if strings.Contains(word, blockType) {
|
|
return fmt.Sprintf("/dev/mapper/%s", word)
|
|
}
|
|
}
|
|
}
|
|
|
|
return ""
|
|
}
|
|
|
|
// UpdateLVMConfig updates the lvm.conf file
|
|
func UpdateLVMConfig(context *clusterd.Context, onPVC, lvBackedPV bool) error {
|
|
|
|
input, err := ioutil.ReadFile(lvmConfPath)
|
|
if err != nil {
|
|
return errors.Wrapf(err, "failed to read lvm config file %q", lvmConfPath)
|
|
}
|
|
|
|
output := bytes.Replace(input, []byte("udev_sync = 1"), []byte("udev_sync = 0"), 1)
|
|
output = bytes.Replace(output, []byte("allow_changes_with_duplicate_pvs = 0"), []byte("allow_changes_with_duplicate_pvs = 1"), 1)
|
|
output = bytes.Replace(output, []byte("udev_rules = 1"), []byte("udev_rules = 0"), 1)
|
|
output = bytes.Replace(output, []byte("use_lvmetad = 1"), []byte("use_lvmetad = 0"), 1)
|
|
output = bytes.Replace(output, []byte("obtain_device_list_from_udev = 1"), []byte("obtain_device_list_from_udev = 0"), 1)
|
|
|
|
// When running on PVC
|
|
if onPVC {
|
|
output = bytes.Replace(output, []byte(`scan = [ "/dev" ]`), []byte(`scan = [ "/dev", "/mnt" ]`), 1)
|
|
// Only filter blocks in /mnt, when running on PVC we copy the PVC claim path to /mnt
|
|
// And reject everything else
|
|
// We have 2 different regex depending on the version of LVM present in the container...
|
|
// Since https://github.com/lvmteam/lvm2/commit/08396b4bce45fb8311979250623f04ec0ddb628c#diff-13c602a6258e57ce666a240e67c44f38
|
|
// the content changed, so depending which version is installled one of the two replace will work
|
|
if lvBackedPV {
|
|
// ceph-volume calls lvs to locate given "vg/lv", so allow "/dev" here. However, ignore loopback devices
|
|
output = bytes.Replace(output, []byte(`# filter = [ "a|.*/|" ]`), []byte(`filter = [ "a|^/mnt/.*|", "r|^/dev/loop.*|", "a|^/dev/.*|", "r|.*|" ]`), 1)
|
|
output = bytes.Replace(output, []byte(`# filter = [ "a|.*|" ]`), []byte(`filter = [ "a|^/mnt/.*|", "r|^/dev/loop.*|", "a|^/dev/.*|", "r|.*|" ]`), 1)
|
|
} else {
|
|
output = bytes.Replace(output, []byte(`# filter = [ "a|.*/|" ]`), []byte(`filter = [ "a|^/mnt/.*|", "r|.*|" ]`), 1)
|
|
output = bytes.Replace(output, []byte(`# filter = [ "a|.*|" ]`), []byte(`filter = [ "a|^/mnt/.*|", "r|.*|" ]`), 1)
|
|
}
|
|
}
|
|
|
|
if err = ioutil.WriteFile(lvmConfPath, output, 0600); err != nil {
|
|
return errors.Wrapf(err, "failed to update lvm config file %q", lvmConfPath)
|
|
}
|
|
|
|
logger.Infof("Successfully updated lvm config file %q", lvmConfPath)
|
|
return nil
|
|
}
|
|
|
|
func (a *OsdAgent) useRawMode(context *clusterd.Context, pvcBacked bool) (bool, error) {
|
|
if pvcBacked {
|
|
return a.clusterInfo.CephVersion.IsAtLeast(cephVolumeRawModeMinCephVersion), nil
|
|
}
|
|
|
|
var useRawMode bool
|
|
if a.clusterInfo.CephVersion.IsOctopus() && a.clusterInfo.CephVersion.IsAtLeast(cephFlockFixOctopusMinCephVersion) {
|
|
logger.Debugf("will use raw mode since cluster version is at least %v", cephFlockFixOctopusMinCephVersion)
|
|
useRawMode = true
|
|
}
|
|
|
|
if a.clusterInfo.CephVersion.IsAtLeastPacific() {
|
|
logger.Debug("will use raw mode since cluster version is at least pacific")
|
|
useRawMode = true
|
|
}
|
|
|
|
// ceph-volume raw mode does not support encryption yet
|
|
if a.storeConfig.EncryptedDevice {
|
|
logger.Debug("won't use raw mode since encryption is enabled")
|
|
useRawMode = false
|
|
}
|
|
|
|
// ceph-volume raw mode does not support more than one OSD per disk
|
|
osdsPerDeviceCountString := sanitizeOSDsPerDevice(a.storeConfig.OSDsPerDevice)
|
|
osdsPerDeviceCount, err := strconv.Atoi(osdsPerDeviceCountString)
|
|
if err != nil {
|
|
return false, errors.Wrapf(err, "failed to convert string %q to integer", osdsPerDeviceCountString)
|
|
}
|
|
if osdsPerDeviceCount > 1 {
|
|
logger.Debugf("won't use raw mode since osd per device is %d", osdsPerDeviceCount)
|
|
useRawMode = false
|
|
}
|
|
|
|
// ceph-volume raw mode mode does not support metadata device if not running on PVC because the user has specified a whole device
|
|
if a.metadataDevice != "" {
|
|
logger.Debugf("won't use raw mode since there is a metadata device %q", a.metadataDevice)
|
|
useRawMode = false
|
|
}
|
|
|
|
return useRawMode, nil
|
|
}
|
|
|
|
func (a *OsdAgent) initializeDevices(context *clusterd.Context, devices *DeviceOsdMapping, allowRawMode bool) error {
|
|
// it's a little strange to split this into parts, looping here and in the init functions, but
|
|
// the LVM mode init requires the ability to loop over all the devices looking for metadata.
|
|
rawDevices := &DeviceOsdMapping{
|
|
Entries: map[string]*DeviceOsdIDEntry{},
|
|
}
|
|
lvmDevices := &DeviceOsdMapping{
|
|
Entries: map[string]*DeviceOsdIDEntry{},
|
|
}
|
|
|
|
for name, device := range devices.Entries {
|
|
// Even if we can use raw mode, do NOT use raw mode on disks. Ceph bluestore disks can
|
|
// sometimes appear as though they have "phantom" Atari (AHDI) partitions created on them
|
|
// when they don't in reality. This is due to a series of bugs in the Linux kernel when it
|
|
// is built with Atari support enabled. This behavior does not appear for raw mode OSDs on
|
|
// partitions, and we need the raw mode to create partition-based OSDs. We cannot merely
|
|
// skip creating OSDs on "phantom" partitions due to a bug in `ceph-volume raw inventory`
|
|
// which reports only the phantom partitions (and malformed OSD info) when they exist and
|
|
// ignores the original (correct) OSDs created on the raw disk.
|
|
// See: https://github.com/rook/rook/issues/7940
|
|
if device.DeviceInfo.Type != sys.DiskType && allowRawMode {
|
|
rawDevices.Entries[name] = device
|
|
continue
|
|
}
|
|
lvmDevices.Entries[name] = device
|
|
}
|
|
|
|
err := a.initializeDevicesRawMode(context, rawDevices)
|
|
if err != nil {
|
|
return err
|
|
}
|
|
|
|
err = a.initializeDevicesLVMMode(context, lvmDevices)
|
|
if err != nil {
|
|
return err
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
func (a *OsdAgent) initializeDevicesRawMode(context *clusterd.Context, devices *DeviceOsdMapping) error {
|
|
baseCommand := "stdbuf"
|
|
cephVolumeMode := "raw"
|
|
baseArgs := []string{"-oL", cephVolumeCmd, cephVolumeMode, "prepare", "--bluestore"}
|
|
|
|
for name, device := range devices.Entries {
|
|
deviceArg := path.Join("/dev", name)
|
|
if device.Data == -1 {
|
|
logger.Infof("configuring new raw device %q", deviceArg)
|
|
|
|
immediateExecuteArgs := append(baseArgs, []string{
|
|
"--data",
|
|
deviceArg,
|
|
}...)
|
|
|
|
// assign the device class specific to the device
|
|
immediateExecuteArgs = a.appendDeviceClassArg(device, immediateExecuteArgs)
|
|
|
|
// execute ceph-volume with the device
|
|
op, err := context.Executor.ExecuteCommandWithCombinedOutput(baseCommand, immediateExecuteArgs...)
|
|
if err != nil {
|
|
cvLogFilePath := path.Join(cephLogDir, "ceph-volume.log")
|
|
|
|
// Print c-v log before exiting
|
|
cvLog := readCVLogContent(cvLogFilePath)
|
|
if cvLog != "" {
|
|
logger.Errorf("%s", cvLog)
|
|
}
|
|
|
|
// Return failure
|
|
return errors.Wrapf(err, "failed to run ceph-volume raw command. %s", op) // fail return here as validation provided by ceph-volume
|
|
}
|
|
logger.Infof("%v", op)
|
|
} else {
|
|
logger.Infof("skipping device %q with osd %d already configured", deviceArg, device.Data)
|
|
}
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
func (a *OsdAgent) initializeDevicesLVMMode(context *clusterd.Context, devices *DeviceOsdMapping) error {
|
|
storeFlag := "--bluestore"
|
|
|
|
logPath := "/tmp/ceph-log"
|
|
if err := os.MkdirAll(logPath, 0700); err != nil {
|
|
return errors.Wrapf(err, "failed to create dir %q", logPath)
|
|
}
|
|
|
|
// Use stdbuf to capture the python output buffer such that we can write to the pod log as the logging happens
|
|
// instead of using the default buffering that will log everything after ceph-volume exits
|
|
baseCommand := "stdbuf"
|
|
baseArgs := []string{"-oL", cephVolumeCmd, "--log-path", logPath, "lvm", "batch", "--prepare", storeFlag, "--yes"}
|
|
if a.storeConfig.EncryptedDevice {
|
|
baseArgs = append(baseArgs, encryptedFlag)
|
|
}
|
|
|
|
osdsPerDeviceCount := sanitizeOSDsPerDevice(a.storeConfig.OSDsPerDevice)
|
|
batchArgs := baseArgs
|
|
|
|
metadataDevices := make(map[string]map[string]string)
|
|
for name, device := range devices.Entries {
|
|
if device.Data == -1 {
|
|
if device.Metadata != nil {
|
|
logger.Infof("skipping metadata device %s config since it will be configured with a data device", name)
|
|
continue
|
|
}
|
|
|
|
logger.Infof("configuring new LVM device %s", name)
|
|
deviceArg := path.Join("/dev", name)
|
|
// ceph-volume prefers to use /dev/mapper/<name> if the device has this kind of alias
|
|
for _, devlink := range device.PersistentDevicePaths {
|
|
if strings.HasPrefix(devlink, "/dev/mapper") {
|
|
deviceArg = devlink
|
|
}
|
|
}
|
|
|
|
deviceOSDCount := osdsPerDeviceCount
|
|
if device.Config.OSDsPerDevice > 1 {
|
|
deviceOSDCount = sanitizeOSDsPerDevice(device.Config.OSDsPerDevice)
|
|
}
|
|
|
|
if a.metadataDevice != "" || device.Config.MetadataDevice != "" {
|
|
// When mixed hdd/ssd devices are given, ceph-volume configures db lv on the ssd.
|
|
// the device will be configured as a batch at the end of the method
|
|
md := a.metadataDevice
|
|
if device.Config.MetadataDevice != "" {
|
|
md = device.Config.MetadataDevice
|
|
}
|
|
logger.Infof("using %s as metadataDevice for device %s and let ceph-volume lvm batch decide how to create volumes", md, deviceArg)
|
|
if _, ok := metadataDevices[md]; ok {
|
|
// Fail when two devices using the same metadata device have different values for osdsPerDevice
|
|
metadataDevices[md]["devices"] += " " + deviceArg
|
|
if deviceOSDCount != metadataDevices[md]["osdsperdevice"] {
|
|
return errors.Errorf("metadataDevice (%s) has more than 1 osdsPerDevice value set: %s != %s", md, deviceOSDCount, metadataDevices[md]["osdsperdevice"])
|
|
}
|
|
} else {
|
|
metadataDevices[md] = make(map[string]string)
|
|
metadataDevices[md]["osdsperdevice"] = deviceOSDCount
|
|
if device.Config.DeviceClass != "" {
|
|
metadataDevices[md]["deviceclass"] = device.Config.DeviceClass
|
|
}
|
|
metadataDevices[md]["devices"] = deviceArg
|
|
}
|
|
deviceDBSizeMB := getDatabaseSize(a.storeConfig.DatabaseSizeMB, device.Config.DatabaseSizeMB)
|
|
if storeFlag == "--bluestore" && deviceDBSizeMB > 0 {
|
|
if deviceDBSizeMB < cephVolumeMinDBSize {
|
|
// ceph-volume will convert this value to ?G. It needs to be > 1G to invoke lvcreate.
|
|
logger.Infof("skipping databaseSizeMB setting (%d). For it should be larger than %dMB.", deviceDBSizeMB, cephVolumeMinDBSize)
|
|
} else {
|
|
dbSizeString := strconv.FormatUint(display.MbTob(uint64(deviceDBSizeMB)), 10)
|
|
if _, ok := metadataDevices[md]["databasesizemb"]; ok {
|
|
if metadataDevices[md]["databasesizemb"] != dbSizeString {
|
|
return errors.Errorf("metadataDevice (%s) has more than 1 databaseSizeMB value set: %s != %s", md, metadataDevices[md]["databasesizemb"], dbSizeString)
|
|
}
|
|
} else {
|
|
metadataDevices[md]["databasesizemb"] = dbSizeString
|
|
}
|
|
}
|
|
}
|
|
} else {
|
|
immediateExecuteArgs := append(baseArgs, []string{
|
|
osdsPerDeviceFlag,
|
|
deviceOSDCount,
|
|
deviceArg,
|
|
}...)
|
|
|
|
// assign the device class specific to the device
|
|
immediateExecuteArgs = a.appendDeviceClassArg(device, immediateExecuteArgs)
|
|
|
|
// Reporting
|
|
immediateReportArgs := append(immediateExecuteArgs, []string{
|
|
"--report",
|
|
}...)
|
|
|
|
logger.Infof("Base command - %+v", baseCommand)
|
|
logger.Infof("immediateExecuteArgs - %+v", immediateExecuteArgs)
|
|
logger.Infof("immediateReportArgs - %+v", immediateReportArgs)
|
|
if err := context.Executor.ExecuteCommand(baseCommand, immediateReportArgs...); err != nil {
|
|
return errors.Wrap(err, "failed ceph-volume report") // fail return here as validation provided by ceph-volume
|
|
}
|
|
|
|
// execute ceph-volume immediately with the device-specific setting instead of batching up multiple devices together
|
|
if err := context.Executor.ExecuteCommand(baseCommand, immediateExecuteArgs...); err != nil {
|
|
cvLog := readCVLogContent("/tmp/ceph-log/ceph-volume.log")
|
|
if cvLog != "" {
|
|
logger.Errorf("%s", cvLog)
|
|
}
|
|
|
|
return errors.Wrap(err, "failed ceph-volume")
|
|
}
|
|
|
|
}
|
|
} else {
|
|
logger.Infof("skipping device %s with osd %d already configured", name, device.Data)
|
|
}
|
|
}
|
|
|
|
for md, conf := range metadataDevices {
|
|
|
|
mdArgs := batchArgs
|
|
if _, ok := conf["osdsperdevice"]; ok {
|
|
mdArgs = append(mdArgs, []string{
|
|
osdsPerDeviceFlag,
|
|
conf["osdsperdevice"],
|
|
}...)
|
|
}
|
|
if _, ok := conf["deviceclass"]; ok {
|
|
mdArgs = append(mdArgs, []string{
|
|
crushDeviceClassFlag,
|
|
conf["deviceclass"],
|
|
}...)
|
|
}
|
|
if _, ok := conf["databasesizemb"]; ok {
|
|
mdArgs = append(mdArgs, []string{
|
|
databaseSizeFlag,
|
|
conf["databasesizemb"],
|
|
}...)
|
|
}
|
|
mdArgs = append(mdArgs, strings.Split(conf["devices"], " ")...)
|
|
|
|
// Do not change device names if udev persistent names are passed
|
|
mdPath := md
|
|
if !strings.HasPrefix(mdPath, "/dev") {
|
|
mdPath = path.Join("/dev", md)
|
|
}
|
|
|
|
mdArgs = append(mdArgs, []string{
|
|
dbDeviceFlag,
|
|
mdPath,
|
|
}...)
|
|
|
|
// Reporting
|
|
reportArgs := append(mdArgs, []string{
|
|
"--report",
|
|
}...)
|
|
|
|
if err := context.Executor.ExecuteCommand(baseCommand, reportArgs...); err != nil {
|
|
return errors.Wrap(err, "failed ceph-volume report") // fail return here as validation provided by ceph-volume
|
|
}
|
|
|
|
reportArgs = append(reportArgs, []string{
|
|
"--format",
|
|
"json",
|
|
}...)
|
|
|
|
cvOut, err := context.Executor.ExecuteCommandWithOutput(baseCommand, reportArgs...)
|
|
if err != nil {
|
|
return errors.Wrapf(err, "failed ceph-volume json report: %s", cvOut) // fail return here as validation provided by ceph-volume
|
|
}
|
|
|
|
logger.Debugf("ceph-volume reports: %+v", cvOut)
|
|
|
|
// ceph version v14.2.13 and v15.2.8 changed the changed output format of `lvm batch --prepare --report`
|
|
// use previous logic if ceph version does not fall into this range
|
|
if !isNewStyledLvmBatch(a.clusterInfo.CephVersion) {
|
|
var cvReport cephVolReport
|
|
if err = json.Unmarshal([]byte(cvOut), &cvReport); err != nil {
|
|
return errors.Wrap(err, "failed to unmarshal ceph-volume report json")
|
|
}
|
|
|
|
if mdPath != cvReport.Vg.Devices {
|
|
return errors.Errorf("ceph-volume did not use the expected metadataDevice [%s]", mdPath)
|
|
}
|
|
} else {
|
|
var cvReports []cephVolReportV2
|
|
if err = json.Unmarshal([]byte(cvOut), &cvReports); err != nil {
|
|
return errors.Wrap(err, "failed to unmarshal ceph-volume report json")
|
|
}
|
|
|
|
if len(strings.Split(conf["devices"], " ")) != len(cvReports) {
|
|
return errors.Errorf("failed to create enough required devices, required: %s, actual: %v", cvOut, cvReports)
|
|
}
|
|
|
|
for _, report := range cvReports {
|
|
if report.BlockDB != mdPath && !strings.HasSuffix(mdPath, report.BlockDB) {
|
|
return errors.Errorf("wrong db device for %s, required: %s, actual: %s", report.Data, mdPath, report.BlockDB)
|
|
}
|
|
}
|
|
}
|
|
|
|
// execute ceph-volume batching up multiple devices
|
|
if err := context.Executor.ExecuteCommand(baseCommand, mdArgs...); err != nil {
|
|
return errors.Wrap(err, "failed ceph-volume") // fail return here as validation provided by ceph-volume
|
|
}
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
func (a *OsdAgent) appendDeviceClassArg(device *DeviceOsdIDEntry, args []string) []string {
|
|
deviceClass := device.Config.DeviceClass
|
|
if deviceClass == "" {
|
|
// fall back to the device class for all devices on the node
|
|
deviceClass = a.storeConfig.DeviceClass
|
|
}
|
|
if deviceClass != "" {
|
|
args = append(args, []string{
|
|
crushDeviceClassFlag,
|
|
deviceClass,
|
|
}...)
|
|
}
|
|
return args
|
|
}
|
|
|
|
func lvmPreReq(context *clusterd.Context, pvcBacked, lvBackedPV bool) error {
|
|
// Check for the presence of LVM on the host when NOT running on PVC
|
|
// since this scenario is still using LVM
|
|
ne := NewNsenter(context, lvmCommandToCheck, []string{"--help"})
|
|
err := ne.checkIfBinaryExistsOnHost()
|
|
if err != nil {
|
|
return errors.Wrapf(err, "binary %q does not exist on the host, make sure lvm2 package is installed", lvmCommandToCheck)
|
|
}
|
|
|
|
// Update LVM configuration file
|
|
// Only do this after Ceph Nautilus 14.2.6 since it will use the ceph-volume raw mode by default and not LVM anymore
|
|
if err := UpdateLVMConfig(context, pvcBacked, lvBackedPV); err != nil {
|
|
return errors.Wrap(err, "failed to update lvm configuration file")
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
func getDatabaseSize(globalSize int, deviceSize int) int {
|
|
if deviceSize > 0 {
|
|
globalSize = deviceSize
|
|
}
|
|
return globalSize
|
|
}
|
|
|
|
func sanitizeOSDsPerDevice(count int) string {
|
|
if count < 1 {
|
|
count = 1
|
|
}
|
|
return strconv.Itoa(count)
|
|
}
|
|
|
|
// GetCephVolumeLVMOSDs list OSD prepared with lvm mode
|
|
func GetCephVolumeLVMOSDs(context *clusterd.Context, clusterInfo *client.ClusterInfo, cephfsid, lv string, skipLVRelease, lvBackedPV bool) ([]oposd.OSDInfo, error) {
|
|
// lv can be a block device if raw mode is used
|
|
cvMode := "lvm"
|
|
|
|
var lvPath string
|
|
args := []string{cvMode, "list", lv, "--format", "json"}
|
|
result, err := callCephVolume(context, false, args...)
|
|
if err != nil {
|
|
return nil, errors.Wrapf(err, "failed to retrieve ceph-volume %s list results", cvMode)
|
|
}
|
|
|
|
var osds []oposd.OSDInfo
|
|
var cephVolumeResult map[string][]osdInfo
|
|
err = json.Unmarshal([]byte(result), &cephVolumeResult)
|
|
if err != nil {
|
|
return nil, errors.Wrapf(err, "failed to unmarshal ceph-volume %s list results. %s", cvMode, result)
|
|
}
|
|
|
|
for name, osdInfo := range cephVolumeResult {
|
|
id, err := strconv.Atoi(name)
|
|
if err != nil {
|
|
logger.Errorf("bad osd returned from ceph-volume %q", name)
|
|
continue
|
|
}
|
|
var osdFSID, osdDeviceClass string
|
|
for _, osd := range osdInfo {
|
|
if osd.Tags.ClusterFSID != cephfsid {
|
|
logger.Infof("skipping osd%d: %q running on a different ceph cluster %q", id, osd.Tags.OSDFSID, osd.Tags.ClusterFSID)
|
|
continue
|
|
}
|
|
osdFSID = osd.Tags.OSDFSID
|
|
osdDeviceClass = osd.Tags.CrushDeviceClass
|
|
|
|
// If no lv is specified let's take the one we discovered
|
|
if lv == "" {
|
|
lvPath = osd.Path
|
|
}
|
|
|
|
}
|
|
|
|
if len(osdFSID) == 0 {
|
|
logger.Infof("Skipping osd%d as no instances are running on ceph cluster %q", id, cephfsid)
|
|
continue
|
|
}
|
|
logger.Infof("osdInfo has %d elements. %+v", len(osdInfo), osdInfo)
|
|
|
|
// If lv was passed as an arg let's use it in osdInfo
|
|
if lv != "" {
|
|
lvPath = lv
|
|
}
|
|
|
|
osd := oposd.OSDInfo{
|
|
ID: id,
|
|
Cluster: "ceph",
|
|
UUID: osdFSID,
|
|
BlockPath: lvPath,
|
|
SkipLVRelease: skipLVRelease,
|
|
LVBackedPV: lvBackedPV,
|
|
CVMode: cvMode,
|
|
Store: "bluestore",
|
|
DeviceClass: osdDeviceClass,
|
|
}
|
|
osds = append(osds, osd)
|
|
}
|
|
logger.Infof("%d ceph-volume lvm osd devices configured on this node", len(osds))
|
|
|
|
return osds, nil
|
|
}
|
|
|
|
func readCVLogContent(cvLogFilePath string) string {
|
|
// Open c-v log file
|
|
cvLogFile, err := os.Open(filepath.Clean(cvLogFilePath))
|
|
if err != nil {
|
|
logger.Errorf("failed to open ceph-volume log file %q. %v", cvLogFilePath, err)
|
|
return ""
|
|
}
|
|
// #nosec G307 Calling defer to close the file without checking the error return is not a risk for a simple file open and close
|
|
defer cvLogFile.Close()
|
|
|
|
// Read c-v log file
|
|
b, err := ioutil.ReadAll(cvLogFile)
|
|
if err != nil {
|
|
logger.Errorf("failed to read ceph-volume log file %q. %v", cvLogFilePath, err)
|
|
return ""
|
|
}
|
|
|
|
return string(b)
|
|
}
|
|
|
|
// GetCephVolumeRawOSDs list OSD prepared with raw mode
|
|
func GetCephVolumeRawOSDs(context *clusterd.Context, clusterInfo *client.ClusterInfo, cephfsid, block, metadataBlock, walBlock string, lvBackedPV, skipDeviceClass bool) ([]oposd.OSDInfo, error) {
|
|
// lv can be a block device if raw mode is used
|
|
cvMode := "raw"
|
|
|
|
// Whether to fill the blockPath using the list result or the value that was passed in the function's call
|
|
var setDevicePathFromList bool
|
|
|
|
// blockPath represents the path of the OSD block
|
|
// it can be the one passed from the function's call or discovered by the c-v list command
|
|
var blockPath string
|
|
|
|
// If block is passed, check if it's an encrypted device, this is needed to get the correct
|
|
// device path and populate the OSDInfo for that OSD
|
|
// When the device is passed, this means we entered the case where no devices were found
|
|
// available, this indicates OSD have been prepared already.
|
|
// However, there is a scenario where we run the prepare job again and this is when the OSD
|
|
// deployment is removed. The operator will reconcile upon deletion of the OSD deployment thus
|
|
// re-running the prepare job to re-hydrate the OSDInfo.
|
|
//
|
|
// isCephEncryptedBlock() returns false if the disk is not a LUKS device with:
|
|
// Device /dev/sdc is not a valid LUKS device.
|
|
if isCephEncryptedBlock(context, cephfsid, block) {
|
|
childDevice, err := sys.ListDevicesChild(context.Executor, block)
|
|
if err != nil {
|
|
return nil, err
|
|
}
|
|
|
|
var encryptedBlock string
|
|
// Find the encrypted block as part of the output
|
|
// Most of the time we get 2 devices, the parent and the child but we don't want to guess
|
|
// which one is the child by looking at the index, instead the iterate over the list
|
|
// Our encrypted device **always** have "-dmcrypt" in the name.
|
|
for _, device := range childDevice {
|
|
if strings.Contains(device, "-dmcrypt") {
|
|
encryptedBlock = device
|
|
break
|
|
}
|
|
}
|
|
if encryptedBlock == "" {
|
|
// The encrypted block is not opened, this is an extreme corner case
|
|
// The OSD deployment has been removed manually AND the node rebooted
|
|
// So we need to re-open the block to re-hydrate the OSDInfo.
|
|
//
|
|
// Handling this case would mean, writing the encryption key on a temporary file, then call
|
|
// luksOpen to open the encrypted block and then call ceph-volume to list against the opened
|
|
// encrypted block.
|
|
// We don't implement this, yet and return an error.
|
|
return nil, errors.Errorf("failed to find the encrypted block device for %q, not opened?", block)
|
|
}
|
|
|
|
// If we have one child device, it should be the encrypted block but still verifying it
|
|
isDeviceEncrypted, err := sys.IsDeviceEncrypted(context.Executor, encryptedBlock)
|
|
if err != nil {
|
|
return nil, err
|
|
}
|
|
|
|
// All good, now we set the right disk for ceph-volume to list against
|
|
// The ceph-volume will look like:
|
|
// [root@bde85e6b23ec /]# ceph-volume raw list /dev/mapper/ocs-deviceset-thin-1-data-0hmfgp-block-dmcrypt
|
|
// {
|
|
// "4": {
|
|
// "ceph_fsid": "fea59c09-2d35-4096-bc46-edb0fd39ab86",
|
|
// "device": "/dev/mapper/ocs-deviceset-thin-1-data-0hmfgp-block-dmcrypt",
|
|
// "osd_id": 4,
|
|
// "osd_uuid": "fcff2062-e653-4d42-84e5-e8de639bed4b",
|
|
// "type": "bluestore"
|
|
// }
|
|
// }
|
|
if isDeviceEncrypted {
|
|
block = encryptedBlock
|
|
}
|
|
}
|
|
|
|
args := []string{cvMode, "list", block, "--format", "json"}
|
|
if block == "" {
|
|
setDevicePathFromList = true
|
|
args = []string{cvMode, "list", "--format", "json"}
|
|
}
|
|
|
|
result, err := callCephVolume(context, false, args...)
|
|
if err != nil {
|
|
return nil, errors.Wrapf(err, "failed to retrieve ceph-volume %s list results", cvMode)
|
|
}
|
|
|
|
var osds []oposd.OSDInfo
|
|
var cephVolumeResult map[string]osdInfoBlock
|
|
err = json.Unmarshal([]byte(result), &cephVolumeResult)
|
|
if err != nil {
|
|
return nil, errors.Wrapf(err, "failed to unmarshal ceph-volume %s list results", cvMode)
|
|
}
|
|
|
|
for _, osdInfo := range cephVolumeResult {
|
|
var osdFSID string
|
|
osdID := osdInfo.OsdID
|
|
|
|
if osdInfo.CephFsid != cephfsid {
|
|
message := fmt.Sprintf("osd.%d: %q belonging to a different ceph cluster %q", osdID, osdInfo.OsdUUID, osdInfo.CephFsid)
|
|
// We must return an error since the caller only checks the length of osds
|
|
if isOnPVC {
|
|
return nil, errors.Errorf("%s", message)
|
|
}
|
|
logger.Infof("skipping %s", message)
|
|
continue
|
|
}
|
|
osdFSID = osdInfo.OsdUUID
|
|
|
|
if len(osdFSID) == 0 {
|
|
message := fmt.Sprintf("no instance of osd.%d is running on ceph cluster %q (incomplete prepare? consider wiping the disks)", osdID, cephfsid)
|
|
if isOnPVC {
|
|
return nil, errors.Errorf("%s", message)
|
|
}
|
|
logger.Infof("skipping since %s", message)
|
|
continue
|
|
}
|
|
|
|
// If no block is specified let's take the one we discovered
|
|
if setDevicePathFromList {
|
|
blockPath = osdInfo.Device
|
|
} else {
|
|
blockPath = block
|
|
}
|
|
|
|
osd := oposd.OSDInfo{
|
|
ID: osdID,
|
|
Cluster: "ceph",
|
|
UUID: osdFSID,
|
|
// let's not use osdInfo.Device, the device reported by bluestore tool since it might change during the next re-attach
|
|
// during the prepare sequence, the device is attached, then detached then re-attached
|
|
// During the last attach it could end up with a different /dev/ name
|
|
// Thus in the activation sequence we might activate the wrong OSD and have OSDInfo messed up
|
|
// Hence, let's use the PVC name instead which will always remain consistent
|
|
BlockPath: blockPath,
|
|
MetadataPath: metadataBlock,
|
|
WalPath: walBlock,
|
|
SkipLVRelease: true,
|
|
LVBackedPV: lvBackedPV,
|
|
CVMode: cvMode,
|
|
Store: "bluestore",
|
|
}
|
|
|
|
if !skipDeviceClass {
|
|
diskInfo, err := clusterd.PopulateDeviceInfo(blockPath, context.Executor)
|
|
if err != nil {
|
|
return nil, errors.Wrapf(err, "failed to get device info for %q", blockPath)
|
|
}
|
|
osd.DeviceClass = sys.GetDiskDeviceClass(diskInfo)
|
|
logger.Infof("setting device class %q for device %q", osd.DeviceClass, diskInfo.Name)
|
|
}
|
|
|
|
// If this is an encrypted OSD
|
|
if os.Getenv(oposd.CephVolumeEncryptedKeyEnvVarName) != "" {
|
|
// If label and subsystem are not set on the encrypted block let's set it
|
|
// They will be set if the OSD deployment has been removed manually and the prepare job
|
|
// runs again.
|
|
// We use /mnt/<pvc_name> since LUKS label/subsystem must be applied on the main block device, not the resulting encrypted dm
|
|
mainBlock := fmt.Sprintf("/mnt/%s", os.Getenv(oposd.PVCNameEnvVarName))
|
|
if !isCephEncryptedBlock(context, cephfsid, mainBlock) {
|
|
// Set subsystem and label for recovery and detection
|
|
err = setLUKSLabelAndSubsystem(context, clusterInfo, mainBlock)
|
|
if err != nil {
|
|
return nil, errors.Wrapf(err, "failed to set subsystem and label to encrypted device %q for osd %d", mainBlock, osdID)
|
|
}
|
|
}
|
|
|
|
// Close encrypted device
|
|
err = closeEncryptedDevice(context, block)
|
|
if err != nil {
|
|
return nil, errors.Wrapf(err, "failed to close encrypted device %q for osd %d", block, osdID)
|
|
}
|
|
|
|
// If there is a metadata block
|
|
if metadataBlock != "" {
|
|
// Close encrypted device
|
|
err = closeEncryptedDevice(context, metadataBlock)
|
|
if err != nil {
|
|
return nil, errors.Wrapf(err, "failed to close encrypted db device %q for osd %d", metadataBlock, osdID)
|
|
}
|
|
}
|
|
|
|
// If there is a wal block
|
|
if walBlock != "" {
|
|
// Close encrypted device
|
|
err = closeEncryptedDevice(context, walBlock)
|
|
if err != nil {
|
|
return nil, errors.Wrapf(err, "failed to close encrypted wal device %q for osd %d", walBlock, osdID)
|
|
}
|
|
}
|
|
}
|
|
|
|
osds = append(osds, osd)
|
|
}
|
|
logger.Infof("%d ceph-volume raw osd devices configured on this node", len(osds))
|
|
|
|
return osds, nil
|
|
}
|
|
|
|
func callCephVolume(context *clusterd.Context, requiresCombinedOutput bool, args ...string) (string, error) {
|
|
// Use stdbuf to capture the python output buffer such that we can write to the pod log as the
|
|
// logging happens instead of using the default buffering that will log everything after
|
|
// ceph-volume exits
|
|
baseCommand := "stdbuf"
|
|
|
|
// Send the log to a temp location that isn't persisted to disk so that we can print out the
|
|
// failure log later without also printing out past failures
|
|
// TODO: does this mess up expectations from the ceph log collector daemon?
|
|
logPath := "/tmp/ceph-log"
|
|
if err := os.MkdirAll(logPath, 0700); err != nil {
|
|
return "", errors.Wrapf(err, "failed to create dir %q", logPath)
|
|
}
|
|
baseArgs := []string{"-oL", cephVolumeCmd, "--log-path", logPath}
|
|
|
|
// Do not use combined output for "list" calls, otherwise we will get stderr is the output and this will break the json unmarshall
|
|
f := context.Executor.ExecuteCommandWithOutput
|
|
if requiresCombinedOutput {
|
|
// If the action is preparing we need the combined output
|
|
f = context.Executor.ExecuteCommandWithCombinedOutput
|
|
}
|
|
co, err := f(baseCommand, append(baseArgs, args...)...)
|
|
if err != nil {
|
|
// Print c-v log before exiting with failure
|
|
cvLog := readCVLogContent("/tmp/ceph-log/ceph-volume.log")
|
|
logger.Errorf("%s", co)
|
|
if cvLog != "" {
|
|
logger.Errorf("%s", cvLog)
|
|
}
|
|
|
|
return "", errors.Wrapf(err, "failed ceph-volume call (see ceph-volume log above for more details)")
|
|
}
|
|
logger.Debugf("%v", co)
|
|
|
|
return co, nil
|
|
}
|
|
|
|
func appendOSDInfo(currentOSDs, osdsToAppend []oposd.OSDInfo) []oposd.OSDInfo {
|
|
for _, osdToAppend := range osdsToAppend {
|
|
if !isInOSDInfoList(osdToAppend.UUID, currentOSDs) {
|
|
currentOSDs = append(currentOSDs, osdToAppend)
|
|
}
|
|
}
|
|
return currentOSDs
|
|
}
|
|
|
|
func isInOSDInfoList(uuid string, osds []oposd.OSDInfo) bool {
|
|
for _, osd := range osds {
|
|
if osd.UUID == uuid {
|
|
return true
|
|
}
|
|
}
|
|
|
|
return false
|
|
}
|