Debugger: Always disable wait indicator when switching engines

The spinning wait indicator in the Locals view could go on infinitely
when the running debugger engine did not get a 'notifyUpdateFinished'
signal (e.g. if the engine quits between beginning and ending an update
cycle).

Change-Id: Ib3d7a88d3b89ed423b2d41e85a632ff01f91c155
Reviewed-by: Eike Ziller <eike.ziller@theqtcompany.com>
This commit is contained in:
hjk
2015-08-17 13:13:08 +02:00
parent 7ea6b21b6d
commit 9bd066cb94

View File

@@ -1759,6 +1759,7 @@ void DebuggerPluginPrivate::connectEngine(DebuggerEngine *engine)
m_inspectorView->setModel(engine->watchModel()); m_inspectorView->setModel(engine->watchModel());
engine->watchHandler()->resetWatchers(); engine->watchHandler()->resetWatchers();
m_localsView->hideProgressIndicator();
m_mainWindow->setEngineDebugLanguages(engine->runParameters().languages); m_mainWindow->setEngineDebugLanguages(engine->runParameters().languages);
} }