Merge pull request #8 from 0x7878/main

Improve configuration and add support for  Cerbo/OS v3.30 and go-eCharger v4
This commit is contained in:
vikt0rm
2025-02-28 20:03:28 +01:00
committed by GitHub
2 changed files with 58 additions and 14 deletions

View File

@@ -7,5 +7,11 @@ HardwareVersion = 4
# Go-e charger AC-Position: 0 = AC out, 1 = AC in
AcPosition = 0
#Possible Options for Log Level: CRITICAL, ERROR, WARNING, INFO, DEBUG, NOTSET
#To keep current.log small use ERROR
Logging=ERROR
[ONPREMISE]
Host=192.168.178.51
#pause 5000ms before the next request
PauseBetweenRequests = 5000

View File

@@ -27,6 +27,10 @@ class DbusGoeChargerService:
deviceinstance = int(config['DEFAULT']['Deviceinstance'])
hardwareVersion = int(config['DEFAULT']['HardwareVersion'])
acPosition = int(config['DEFAULT']['AcPosition'])
pauseBetweenRequests = int(config['ONPREMISE']['PauseBetweenRequests']) # in ms
if pauseBetweenRequests <= 20:
raise ValueError("Pause between requests must be greater than 20")
self._dbusservice = VeDbusService("{}.http_{:02d}".format(servicename, deviceinstance), register=False)
self._paths = paths
@@ -83,7 +87,7 @@ class DbusGoeChargerService:
self._chargingTime = 0.0
# add _update function 'timer'
gobject.timeout_add(250, self._update) # pause 250ms before the next request
gobject.timeout_add(pauseBetweenRequests, self._update)
# add _signOfLife 'timer' to get feedback in log every 5minutes
gobject.timeout_add(self._getSignOfLifeInterval()*60*1000, self._signOfLife)
@@ -109,9 +113,9 @@ class DbusGoeChargerService:
accessType = config['DEFAULT']['AccessType']
if accessType == 'OnPremise':
URL = "http://%s/api/status" % (config['ONPREMISE']['Host'])
URL = "http://%s/api/status" % (config['ONPREMISE']['Host'])
else:
raise ValueError("AccessType %s is not supported" % (config['DEFAULT']['AccessType']))
raise ValueError("AccessType %s is not supported" % (config['DEFAULT']['AccessType']))
return URL
@@ -178,17 +182,48 @@ class DbusGoeChargerService:
def _update(self):
try:
#get data from go-eCharger
data = self._getGoeChargerData('nrg,eto,alw,amp,ama,car,tmp,tma')
data = self._getGoeChargerData('nrg,eto,wh,alw,amp,ama,car,tmp,tma')
if data is not None:
'''
data['nrg']
0 = U L1
1 = U L2
2 = U L3
3 = U N
4 = I L1
5 = I L2
6 = I L3
7 = P L1
8 = P L2
9 = P L3
10 = P N
11 = P Total
12 = PF L1
13 = PF L2
14 = PF L3
15 = PF N
'''
config = self._getConfig()
hardwareVersion = int(config['DEFAULT']['HardwareVersion'])
#send data to DBus
self._dbusservice['/Ac/L1/Power'] = int(data['nrg'][7])
self._dbusservice['/Ac/L2/Power'] = int(data['nrg'][8])
self._dbusservice['/Ac/L3/Power'] = int(data['nrg'][9])
self._dbusservice['/Ac/Power'] = int(data['nrg'][11])
self._dbusservice['/Ac/Voltage'] = int(data['nrg'][0])
self._dbusservice['/Current'] = max(data['nrg'][4], data['nrg'][5], data['nrg'][6])
self._dbusservice['/Ac/Energy/Forward'] = int(float(data['eto']) / 1000.0)
if hardwareVersion < 4
self._dbusservice['/Ac/L1/Power'] = int(data['nrg'][7])
self._dbusservice['/Ac/L2/Power'] = int(data['nrg'][8])
self._dbusservice['/Ac/L3/Power'] = int(data['nrg'][9])
self._dbusservice['/Ac/Power'] = int(data['nrg'][11])
self._dbusservice['/Ac/Energy/Forward'] = int(float(data['eto']) / 1000.0)
self._dbusservice['/Current'] = max(data['nrg'][4], data['nrg'][5], data['nrg'][6])
else
self._dbusservice['/Ac/L1/Power'] = int(data['nrg'][7] * 0.1 * 1000)
self._dbusservice['/Ac/L2/Power'] = int(data['nrg'][8] * 0.1 * 1000)
self._dbusservice['/Ac/L3/Power'] = int(data['nrg'][9] * 0.1 * 1000)
self._dbusservice['/Ac/Power'] = int(data['nrg'][11] * 0.01 * 1000)
self._dbusservice['/Ac/Energy/Forward'] = round(data['wh'] / 1000, 2)
self._dbusservice['/Current'] = max(data['nrg'][4] * 0.1, data['nrg'][5] * 0.1, data['nrg'][6] * 0.1)
self._dbusservice['/StartStop'] = int(data['alw'])
self._dbusservice['/SetCurrent'] = int(data['amp'])
@@ -204,8 +239,7 @@ class DbusGoeChargerService:
self._dbusservice['/Mode'] = 0 # Manual, no control
config = self._getConfig()
hardwareVersion = int(config['DEFAULT']['HardwareVersion'])
if hardwareVersion >= 3:
self._dbusservice['/MCU/Temperature'] = int(data['tma'][0] if data['tma'] is not None else 0)
else:
@@ -262,9 +296,13 @@ class DbusGoeChargerService:
def main():
#configure logging
config = configparser.ConfigParser()
config.read(f"{(os.path.dirname(os.path.realpath(__file__)))}/config.ini")
logging_level = config["DEFAULT"]["Logging"].upper()
logging.basicConfig( format='%(asctime)s,%(msecs)d %(name)s %(levelname)s %(message)s',
datefmt='%Y-%m-%d %H:%M:%S',
level=logging.INFO,
level=logging_level,
handlers=[
RotatingFileHandler("%s/current.log" % (os.path.dirname(os.path.realpath(__file__))), maxBytes=10000),
logging.StreamHandler()