fix charge current

This commit is contained in:
Viktor Markstädter
2025-02-27 12:31:41 +01:00
parent 6ab1882df8
commit 8940267b55

View File

@@ -187,7 +187,7 @@ class DbusGoeChargerService:
self._dbusservice['/Ac/L3/Power'] = int(data['nrg'][9])
self._dbusservice['/Ac/Power'] = int(data['nrg'][11])
self._dbusservice['/Ac/Voltage'] = int(data['nrg'][0])
self._dbusservice['/Current'] = max(data['nrg'][4] * 0.1, data['nrg'][5] * 0.1, data['nrg'][6] * 0.1)
self._dbusservice['/Current'] = max(data['nrg'][4], data['nrg'][5], data['nrg'][6])
self._dbusservice['/Ac/Energy/Forward'] = int(float(data['eto']) / 10.0)
self._dbusservice['/StartStop'] = int(data['alw'])