@@ -25,6 +25,14 @@ class DbusGoeChargerService:
|
||||
config = self._getConfig()
|
||||
deviceinstance = int(config['DEFAULT']['Deviceinstance'])
|
||||
hardwareVersion = int(config['DEFAULT']['HardwareVersion'])
|
||||
pauseBetweenRequests = int(config['ONPREMISE']['PauseBetweenRequests']) # in ms
|
||||
position = int(config['DEFAULT'].get('Position', '1'))
|
||||
|
||||
if pauseBetweenRequests <= 20:
|
||||
raise ValueError("Pause between requests must be greater than 20")
|
||||
|
||||
if hardwareVersion < 4:
|
||||
raise ValueError("Minimum hardware version required is 4.")
|
||||
|
||||
self._dbusservice = VeDbusService("{}.http_{:02d}".format(servicename, deviceinstance))
|
||||
self._paths = paths
|
||||
@@ -55,6 +63,7 @@ class DbusGoeChargerService:
|
||||
self._dbusservice.add_path('/HardwareVersion', hardwareVersion)
|
||||
self._dbusservice.add_path('/Connected', 1)
|
||||
self._dbusservice.add_path('/UpdateIndex', 0)
|
||||
self._dbusservice.add_path("/Position", position)
|
||||
|
||||
# add paths without units
|
||||
for path in paths_wo_unit:
|
||||
@@ -72,7 +81,7 @@ class DbusGoeChargerService:
|
||||
self._chargingTime = 0.0
|
||||
|
||||
# add _update function 'timer'
|
||||
gobject.timeout_add(250, self._update) # pause 250ms before the next request
|
||||
gobject.timeout_add(pauseBetweenRequests, self._update)
|
||||
|
||||
# add _signOfLife 'timer' to get feedback in log every 5minutes
|
||||
gobject.timeout_add(self._getSignOfLifeInterval()*60*1000, self._signOfLife)
|
||||
@@ -98,7 +107,7 @@ class DbusGoeChargerService:
|
||||
accessType = config['DEFAULT']['AccessType']
|
||||
|
||||
if accessType == 'OnPremise':
|
||||
URL = "http://%s/status" % (config['ONPREMISE']['Host'])
|
||||
URL = "http://%s/api/status?filter=fwv,sse,nrg,wh,alw,amp,ama,car" % (config['ONPREMISE']['Host'])
|
||||
else:
|
||||
raise ValueError("AccessType %s is not supported" % (config['DEFAULT']['AccessType']))
|
||||
|
||||
@@ -170,19 +179,38 @@ class DbusGoeChargerService:
|
||||
data = self._getGoeChargerData()
|
||||
|
||||
if data is not None:
|
||||
|
||||
'''
|
||||
data['nrg']
|
||||
0 = U L1
|
||||
1 = U L2
|
||||
2 = U L3
|
||||
3 = U N
|
||||
4 = I L1
|
||||
5 = I L2
|
||||
6 = I L3
|
||||
7 = P L1
|
||||
8 = P L2
|
||||
9 = P L3
|
||||
10 = P N
|
||||
11 = P Total
|
||||
12 = PF L1
|
||||
13 = PF L2
|
||||
14 = PF L3
|
||||
15 = PF N
|
||||
'''
|
||||
|
||||
#send data to DBus
|
||||
self._dbusservice['/Ac/L1/Power'] = int(data['nrg'][7] * 0.1 * 1000)
|
||||
self._dbusservice['/Ac/L2/Power'] = int(data['nrg'][8] * 0.1 * 1000)
|
||||
self._dbusservice['/Ac/L3/Power'] = int(data['nrg'][9] * 0.1 * 1000)
|
||||
self._dbusservice['/Ac/Power'] = int(data['nrg'][11] * 0.01 * 1000)
|
||||
self._dbusservice['/Ac/Voltage'] = int(data['nrg'][0])
|
||||
self._dbusservice['/Current'] = max(data['nrg'][4] * 0.1, data['nrg'][5] * 0.1, data['nrg'][6] * 0.1)
|
||||
self._dbusservice['/Ac/Energy/Forward'] = int(float(data['eto']) / 10.0)
|
||||
self._dbusservice['/Ac/L1/Power'] = int(data['nrg'][7])
|
||||
self._dbusservice['/Ac/L2/Power'] = int(data['nrg'][8])
|
||||
self._dbusservice['/Ac/L3/Power'] = int(data['nrg'][9])
|
||||
self._dbusservice['/Ac/Power'] = int(data['nrg'][11])
|
||||
self._dbusservice['/Current'] = max(data['nrg'][4], data['nrg'][5], data['nrg'][6])
|
||||
self._dbusservice['/Ac/Energy/Forward'] = round(data['wh'] / 1000, 2)
|
||||
|
||||
self._dbusservice['/StartStop'] = int(data['alw'])
|
||||
self._dbusservice['/SetCurrent'] = int(data['amp'])
|
||||
self._dbusservice['/MaxCurrent'] = int(data['ama'])
|
||||
|
||||
# update chargingTime, increment charge time only on active charging (2), reset when no car connected (1)
|
||||
timeDelta = time.time() - self._lastUpdate
|
||||
if int(data['car']) == 2 and self._lastUpdate > 0: # vehicle loads
|
||||
@@ -192,13 +220,6 @@ class DbusGoeChargerService:
|
||||
self._dbusservice['/ChargingTime'] = int(self._chargingTime)
|
||||
|
||||
self._dbusservice['/Mode'] = 0 # Manual, no control
|
||||
|
||||
config = self._getConfig()
|
||||
hardwareVersion = int(config['DEFAULT']['HardwareVersion'])
|
||||
if hardwareVersion == 3:
|
||||
self._dbusservice['/MCU/Temperature'] = int(data['tma'][0])
|
||||
else:
|
||||
self._dbusservice['/MCU/Temperature'] = int(data['tmp'])
|
||||
|
||||
# value 'car' 1: charging station ready, no vehicle 2: vehicle loads 3: Waiting for vehicle 4: Charge finished, vehicle still connected
|
||||
status = 0
|
||||
@@ -250,9 +271,13 @@ class DbusGoeChargerService:
|
||||
|
||||
def main():
|
||||
#configure logging
|
||||
config = configparser.ConfigParser()
|
||||
config.read(f"{(os.path.dirname(os.path.realpath(__file__)))}/config.ini")
|
||||
logging_level = config["DEFAULT"]["Logging"].upper()
|
||||
|
||||
logging.basicConfig( format='%(asctime)s,%(msecs)d %(name)s %(levelname)s %(message)s',
|
||||
datefmt='%Y-%m-%d %H:%M:%S',
|
||||
level=logging.INFO,
|
||||
level=logging_level,
|
||||
handlers=[
|
||||
logging.FileHandler("%s/current.log" % (os.path.dirname(os.path.realpath(__file__)))),
|
||||
logging.StreamHandler()
|
||||
|
Reference in New Issue
Block a user