mirror of
https://github.com/vikt0rm/dbus-goecharger.git
synced 2025-08-03 04:04:27 +02:00
Improved and added v4 go-charger compatibility
This commit is contained in:
@@ -25,6 +25,14 @@ class DbusGoeChargerService:
|
|||||||
config = self._getConfig()
|
config = self._getConfig()
|
||||||
deviceinstance = int(config['DEFAULT']['Deviceinstance'])
|
deviceinstance = int(config['DEFAULT']['Deviceinstance'])
|
||||||
hardwareVersion = int(config['DEFAULT']['HardwareVersion'])
|
hardwareVersion = int(config['DEFAULT']['HardwareVersion'])
|
||||||
|
pauseBetweenRequests = int(config['ONPREMISE']['PauseBetweenRequests']) # in ms
|
||||||
|
position = int(config['DEFAULT'].get('Position', '1'))
|
||||||
|
|
||||||
|
if pauseBetweenRequests <= 20:
|
||||||
|
raise ValueError("Pause between requests must be greater than 20")
|
||||||
|
|
||||||
|
if hardwareVersion < 4:
|
||||||
|
raise ValueError("Minimum hardware version required is 4.")
|
||||||
|
|
||||||
self._dbusservice = VeDbusService("{}.http_{:02d}".format(servicename, deviceinstance))
|
self._dbusservice = VeDbusService("{}.http_{:02d}".format(servicename, deviceinstance))
|
||||||
self._paths = paths
|
self._paths = paths
|
||||||
@@ -55,6 +63,7 @@ class DbusGoeChargerService:
|
|||||||
self._dbusservice.add_path('/HardwareVersion', hardwareVersion)
|
self._dbusservice.add_path('/HardwareVersion', hardwareVersion)
|
||||||
self._dbusservice.add_path('/Connected', 1)
|
self._dbusservice.add_path('/Connected', 1)
|
||||||
self._dbusservice.add_path('/UpdateIndex', 0)
|
self._dbusservice.add_path('/UpdateIndex', 0)
|
||||||
|
self._dbusservice.add_path("/Position", position)
|
||||||
|
|
||||||
# add paths without units
|
# add paths without units
|
||||||
for path in paths_wo_unit:
|
for path in paths_wo_unit:
|
||||||
@@ -72,7 +81,7 @@ class DbusGoeChargerService:
|
|||||||
self._chargingTime = 0.0
|
self._chargingTime = 0.0
|
||||||
|
|
||||||
# add _update function 'timer'
|
# add _update function 'timer'
|
||||||
gobject.timeout_add(250, self._update) # pause 250ms before the next request
|
gobject.timeout_add(pauseBetweenRequests, self._update)
|
||||||
|
|
||||||
# add _signOfLife 'timer' to get feedback in log every 5minutes
|
# add _signOfLife 'timer' to get feedback in log every 5minutes
|
||||||
gobject.timeout_add(self._getSignOfLifeInterval()*60*1000, self._signOfLife)
|
gobject.timeout_add(self._getSignOfLifeInterval()*60*1000, self._signOfLife)
|
||||||
@@ -98,7 +107,7 @@ class DbusGoeChargerService:
|
|||||||
accessType = config['DEFAULT']['AccessType']
|
accessType = config['DEFAULT']['AccessType']
|
||||||
|
|
||||||
if accessType == 'OnPremise':
|
if accessType == 'OnPremise':
|
||||||
URL = "http://%s/status" % (config['ONPREMISE']['Host'])
|
URL = "http://%s/api/status?filter=fwv,sse,nrg,wh,alw,amp,ama,car" % (config['ONPREMISE']['Host'])
|
||||||
else:
|
else:
|
||||||
raise ValueError("AccessType %s is not supported" % (config['DEFAULT']['AccessType']))
|
raise ValueError("AccessType %s is not supported" % (config['DEFAULT']['AccessType']))
|
||||||
|
|
||||||
@@ -170,19 +179,38 @@ class DbusGoeChargerService:
|
|||||||
data = self._getGoeChargerData()
|
data = self._getGoeChargerData()
|
||||||
|
|
||||||
if data is not None:
|
if data is not None:
|
||||||
|
|
||||||
|
'''
|
||||||
|
data['nrg']
|
||||||
|
0 = U L1
|
||||||
|
1 = U L2
|
||||||
|
2 = U L3
|
||||||
|
3 = U N
|
||||||
|
4 = I L1
|
||||||
|
5 = I L2
|
||||||
|
6 = I L3
|
||||||
|
7 = P L1
|
||||||
|
8 = P L2
|
||||||
|
9 = P L3
|
||||||
|
10 = P N
|
||||||
|
11 = P Total
|
||||||
|
12 = PF L1
|
||||||
|
13 = PF L2
|
||||||
|
14 = PF L3
|
||||||
|
15 = PF N
|
||||||
|
'''
|
||||||
|
|
||||||
#send data to DBus
|
#send data to DBus
|
||||||
self._dbusservice['/Ac/L1/Power'] = int(data['nrg'][7] * 0.1 * 1000)
|
self._dbusservice['/Ac/L1/Power'] = int(data['nrg'][7])
|
||||||
self._dbusservice['/Ac/L2/Power'] = int(data['nrg'][8] * 0.1 * 1000)
|
self._dbusservice['/Ac/L2/Power'] = int(data['nrg'][8])
|
||||||
self._dbusservice['/Ac/L3/Power'] = int(data['nrg'][9] * 0.1 * 1000)
|
self._dbusservice['/Ac/L3/Power'] = int(data['nrg'][9])
|
||||||
self._dbusservice['/Ac/Power'] = int(data['nrg'][11] * 0.01 * 1000)
|
self._dbusservice['/Ac/Power'] = int(data['nrg'][11])
|
||||||
self._dbusservice['/Ac/Voltage'] = int(data['nrg'][0])
|
self._dbusservice['/Current'] = max(data['nrg'][4], data['nrg'][5], data['nrg'][6])
|
||||||
self._dbusservice['/Current'] = max(data['nrg'][4] * 0.1, data['nrg'][5] * 0.1, data['nrg'][6] * 0.1)
|
self._dbusservice['/Ac/Energy/Forward'] = round(data['wh'] / 1000, 2)
|
||||||
self._dbusservice['/Ac/Energy/Forward'] = int(float(data['eto']) / 10.0)
|
|
||||||
|
|
||||||
self._dbusservice['/StartStop'] = int(data['alw'])
|
self._dbusservice['/StartStop'] = int(data['alw'])
|
||||||
self._dbusservice['/SetCurrent'] = int(data['amp'])
|
self._dbusservice['/SetCurrent'] = int(data['amp'])
|
||||||
self._dbusservice['/MaxCurrent'] = int(data['ama'])
|
self._dbusservice['/MaxCurrent'] = int(data['ama'])
|
||||||
|
|
||||||
# update chargingTime, increment charge time only on active charging (2), reset when no car connected (1)
|
# update chargingTime, increment charge time only on active charging (2), reset when no car connected (1)
|
||||||
timeDelta = time.time() - self._lastUpdate
|
timeDelta = time.time() - self._lastUpdate
|
||||||
if int(data['car']) == 2 and self._lastUpdate > 0: # vehicle loads
|
if int(data['car']) == 2 and self._lastUpdate > 0: # vehicle loads
|
||||||
@@ -192,13 +220,6 @@ class DbusGoeChargerService:
|
|||||||
self._dbusservice['/ChargingTime'] = int(self._chargingTime)
|
self._dbusservice['/ChargingTime'] = int(self._chargingTime)
|
||||||
|
|
||||||
self._dbusservice['/Mode'] = 0 # Manual, no control
|
self._dbusservice['/Mode'] = 0 # Manual, no control
|
||||||
|
|
||||||
config = self._getConfig()
|
|
||||||
hardwareVersion = int(config['DEFAULT']['HardwareVersion'])
|
|
||||||
if hardwareVersion == 3:
|
|
||||||
self._dbusservice['/MCU/Temperature'] = int(data['tma'][0])
|
|
||||||
else:
|
|
||||||
self._dbusservice['/MCU/Temperature'] = int(data['tmp'])
|
|
||||||
|
|
||||||
# value 'car' 1: charging station ready, no vehicle 2: vehicle loads 3: Waiting for vehicle 4: Charge finished, vehicle still connected
|
# value 'car' 1: charging station ready, no vehicle 2: vehicle loads 3: Waiting for vehicle 4: Charge finished, vehicle still connected
|
||||||
status = 0
|
status = 0
|
||||||
@@ -250,9 +271,13 @@ class DbusGoeChargerService:
|
|||||||
|
|
||||||
def main():
|
def main():
|
||||||
#configure logging
|
#configure logging
|
||||||
|
config = configparser.ConfigParser()
|
||||||
|
config.read(f"{(os.path.dirname(os.path.realpath(__file__)))}/config.ini")
|
||||||
|
logging_level = config["DEFAULT"]["Logging"].upper()
|
||||||
|
|
||||||
logging.basicConfig( format='%(asctime)s,%(msecs)d %(name)s %(levelname)s %(message)s',
|
logging.basicConfig( format='%(asctime)s,%(msecs)d %(name)s %(levelname)s %(message)s',
|
||||||
datefmt='%Y-%m-%d %H:%M:%S',
|
datefmt='%Y-%m-%d %H:%M:%S',
|
||||||
level=logging.INFO,
|
level=logging_level,
|
||||||
handlers=[
|
handlers=[
|
||||||
logging.FileHandler("%s/current.log" % (os.path.dirname(os.path.realpath(__file__)))),
|
logging.FileHandler("%s/current.log" % (os.path.dirname(os.path.realpath(__file__)))),
|
||||||
logging.StreamHandler()
|
logging.StreamHandler()
|
||||||
|
Reference in New Issue
Block a user