mirror of
https://github.com/vikt0rm/dbus-goecharger.git
synced 2025-07-30 18:37:13 +02:00
Add hardwareVersion check
HardwareVersion check is needed, because GoE v3 is using a different parameter to get controller temperature (`tma` instead of `tmp`)
This commit is contained in:
@ -24,7 +24,8 @@ class DbusGoeChargerService:
|
|||||||
def __init__(self, servicename, paths, productname='go-eCharger', connection='go-eCharger HTTP JSON service'):
|
def __init__(self, servicename, paths, productname='go-eCharger', connection='go-eCharger HTTP JSON service'):
|
||||||
config = self._getConfig()
|
config = self._getConfig()
|
||||||
deviceinstance = int(config['DEFAULT']['Deviceinstance'])
|
deviceinstance = int(config['DEFAULT']['Deviceinstance'])
|
||||||
|
hardwareVersion = int(config['DEFAULT']['HardwareVersion'])
|
||||||
|
|
||||||
self._dbusservice = VeDbusService("{}.http_{:02d}".format(servicename, deviceinstance))
|
self._dbusservice = VeDbusService("{}.http_{:02d}".format(servicename, deviceinstance))
|
||||||
self._paths = paths
|
self._paths = paths
|
||||||
|
|
||||||
@ -49,7 +50,7 @@ class DbusGoeChargerService:
|
|||||||
self._dbusservice.add_path('/ProductName', productname)
|
self._dbusservice.add_path('/ProductName', productname)
|
||||||
self._dbusservice.add_path('/CustomName', productname)
|
self._dbusservice.add_path('/CustomName', productname)
|
||||||
self._dbusservice.add_path('/FirmwareVersion', int(data['fwv'].replace('.', '')))
|
self._dbusservice.add_path('/FirmwareVersion', int(data['fwv'].replace('.', '')))
|
||||||
self._dbusservice.add_path('/HardwareVersion', 2)
|
self._dbusservice.add_path('/HardwareVersion', hardwareVersion)
|
||||||
self._dbusservice.add_path('/Serial', data['sse'])
|
self._dbusservice.add_path('/Serial', data['sse'])
|
||||||
self._dbusservice.add_path('/Connected', 1)
|
self._dbusservice.add_path('/Connected', 1)
|
||||||
self._dbusservice.add_path('/UpdateIndex', 0)
|
self._dbusservice.add_path('/UpdateIndex', 0)
|
||||||
@ -186,7 +187,13 @@ class DbusGoeChargerService:
|
|||||||
self._dbusservice['/ChargingTime'] = int(self._chargingTime)
|
self._dbusservice['/ChargingTime'] = int(self._chargingTime)
|
||||||
|
|
||||||
self._dbusservice['/Mode'] = 0 # Manual, no control
|
self._dbusservice['/Mode'] = 0 # Manual, no control
|
||||||
self._dbusservice['/MCU/Temperature'] = int(data['tmp'])
|
|
||||||
|
config = self._getConfig()
|
||||||
|
hardwareVersion = int(config['DEFAULT']['HardwareVersion'])
|
||||||
|
if hardwareVersion == 3:
|
||||||
|
self._dbusservice['/MCU/Temperature'] = int(data['tma'][0])
|
||||||
|
else:
|
||||||
|
self._dbusservice['/MCU/Temperature'] = int(data['tmp'])
|
||||||
|
|
||||||
# value 'car' 1: charging station ready, no vehicle 2: vehicle loads 3: Waiting for vehicle 4: Charge finished, vehicle still connected
|
# value 'car' 1: charging station ready, no vehicle 2: vehicle loads 3: Waiting for vehicle 4: Charge finished, vehicle still connected
|
||||||
status = 0
|
status = 0
|
||||||
|
Reference in New Issue