#!/usr/bin/env python
|
|
|
|
# import normal packages
|
|
import platform
|
|
import logging
|
|
import sys
|
|
import os
|
|
import sys
|
|
if sys.version_info.major == 2:
|
|
import gobject
|
|
else:
|
|
from gi.repository import GLib as gobject
|
|
import sys
|
|
import time
|
|
import requests # for http GET
|
|
import configparser # for config/ini file
|
|
|
|
# our own packages from victron
|
|
sys.path.insert(1, os.path.join(os.path.dirname(__file__), '/opt/victronenergy/dbus-systemcalc-py/ext/velib_python'))
|
|
from vedbus import VeDbusService
|
|
|
|
|
|
class DbusGoeChargerService:
|
|
def __init__(self, servicename, paths, productname='go-eCharger', connection='go-eCharger HTTP JSON service'):
|
|
config = self._getConfig()
|
|
deviceinstance = int(config['DEFAULT']['Deviceinstance'])
|
|
|
|
self._dbusservice = VeDbusService("{}.http_{:02d}".format(servicename, deviceinstance))
|
|
self._paths = paths
|
|
|
|
logging.debug("%s /DeviceInstance = %d" % (servicename, deviceinstance))
|
|
|
|
paths_wo_unit = [
|
|
'/Ac/Frequency',
|
|
'/Status',
|
|
'/Mode',
|
|
'/ChargingTime',
|
|
'/PCB/Temperature',
|
|
'/MCU/Temperature',
|
|
'/History/ChargingCycles',
|
|
'/History/ConnectorCycles',
|
|
'/History/Ac/Energy/Forward',
|
|
'/History/Uptime',
|
|
'/History/ChargingTime',
|
|
'/History/Alerts',
|
|
'/History/AverageStartupTemperature',
|
|
'/History/AbortedChargingCycles',
|
|
'/History/ThermalFoldbacks'
|
|
]
|
|
|
|
# Create the management objects, as specified in the ccgx dbus-api document
|
|
self._dbusservice.add_path('/Mgmt/ProcessName', __file__)
|
|
self._dbusservice.add_path('/Mgmt/ProcessVersion', 'Unkown version, and running on Python ' + platform.python_version())
|
|
self._dbusservice.add_path('/Mgmt/Connection', connection)
|
|
|
|
# Create the mandatory objects
|
|
self._dbusservice.add_path('/DeviceInstance', deviceinstance)
|
|
self._dbusservice.add_path('/ProductId', 0xFFFF) #
|
|
self._dbusservice.add_path('/ProductName', productname)
|
|
self._dbusservice.add_path('/CustomName', productname)
|
|
self._dbusservice.add_path('/FirmwareVersion', 0.1)
|
|
self._dbusservice.add_path('/HardwareVersion', 0)
|
|
self._dbusservice.add_path('/Connected', 1)
|
|
self._dbusservice.add_path('/UpdateIndex', 0)
|
|
|
|
# add paths without units
|
|
for path in paths_wo_unit:
|
|
self._dbusservice.add_path(path, None)
|
|
|
|
# add path values to dbus
|
|
for path, settings in self._paths.items():
|
|
self._dbusservice.add_path(
|
|
path, settings['initial'], gettextcallback=settings['textformat'], writeable=True, onchangecallback=self._handlechangedvalue)
|
|
|
|
# last update
|
|
self._lastUpdate = 0
|
|
|
|
# add _update function 'timer'
|
|
gobject.timeout_add(250, self._update) # pause 250ms before the next request
|
|
|
|
# add _signOfLife 'timer' to get feedback in log every 5minutes
|
|
gobject.timeout_add(self._getSignOfLifeInterval()*60*1000, self._signOfLife)
|
|
|
|
def _getConfig(self):
|
|
config = configparser.ConfigParser()
|
|
config.read("%s/config.ini" % (os.path.dirname(os.path.realpath(__file__))))
|
|
return config;
|
|
|
|
|
|
def _getSignOfLifeInterval(self):
|
|
config = self._getConfig()
|
|
value = config['DEFAULT']['SignOfLifeLog']
|
|
|
|
if not value:
|
|
value = 0
|
|
|
|
return int(value)
|
|
|
|
|
|
def _getGoeChargerStatusUrl(self):
|
|
config = self._getConfig()
|
|
accessType = config['DEFAULT']['AccessType']
|
|
|
|
if accessType == 'OnPremise':
|
|
URL = "http://%s/status" % (config['ONPREMISE']['Host'])
|
|
else:
|
|
raise ValueError("AccessType %s is not supported" % (config['DEFAULT']['AccessType']))
|
|
|
|
return URL
|
|
|
|
|
|
def _getGoeChargerData(self):
|
|
URL = self._getGoeChargerStatusUrl()
|
|
request_data = requests.get(url = URL)
|
|
|
|
# check for response
|
|
if not request_data:
|
|
raise ConnectionError("No response from go-eCharger - %s" % (URL))
|
|
|
|
json_data = request_data.json()
|
|
|
|
# check for Json
|
|
if not json_data:
|
|
raise ValueError("Converting response to JSON failed")
|
|
|
|
|
|
return json_data
|
|
|
|
|
|
def _signOfLife(self):
|
|
logging.info("--- Start: sign of life ---")
|
|
logging.info("Last _update() call: %s" % (self._lastUpdate))
|
|
logging.info("Last '/Ac/Power': %s" % (self._dbusservice['/Ac/Power']))
|
|
logging.info("--- End: sign of life ---")
|
|
return True
|
|
|
|
def _update(self):
|
|
try:
|
|
#get data from go-eCharger
|
|
data = self._getGoeChargerData()
|
|
|
|
config = self._getConfig()
|
|
|
|
#send data to DBus
|
|
self._dbusservice['/Ac/L1/Power'] = int(data['nrg'][7] * 0.1 * 1000)
|
|
self._dbusservice['/Ac/L2/Power'] = int(data['nrg'][8] * 0.1 * 1000)
|
|
self._dbusservice['/Ac/L3/Power'] = int(data['nrg'][9] * 0.1 * 1000)
|
|
self._dbusservice['/Ac/Power'] = int(data['nrg'][11] * 0.01 * 1000)
|
|
self._dbusservice['/Ac/Frequency'] = 0
|
|
self._dbusservice['/Ac/Voltage'] = data['grid_v']
|
|
self._dbusservice['/Current'] = data['vehicle_current_a']
|
|
self._dbusservice['/SetCurrent'] = 16 # static for now
|
|
self._dbusservice['/MaxCurrent'] = 16 # data['vehicle_current_a']
|
|
# self._dbusservice['/Ac/Energy/Forward'] = float(data['session_energy_wh']) / 1000.0
|
|
self._dbusservice['/Ac/Energy/Forward'] = float(lt['energy_wh']) / 1000.0
|
|
self._dbusservice['/ChargingTime'] = data['session_s']
|
|
|
|
self._dbusservice['/Ac/Power'] = self._dbusservice['/Ac/' + pvinverter_phase + '/Power']
|
|
self._dbusservice['/Ac/Energy/Forward'] = self._dbusservice['/Ac/' + pvinverter_phase + '/Energy/Forward']
|
|
|
|
#logging
|
|
logging.debug("Wallbox Consumption (/Ac/Power): %s" % (self._dbusservice['/Ac/Power']))
|
|
logging.debug("Wallbox Forward (/Ac/Energy/Forward): %s" % (self._dbusservice['/Ac/Energy/Forward']))
|
|
logging.debug("---");
|
|
|
|
# increment UpdateIndex - to show that new data is available
|
|
index = self._dbusservice['/UpdateIndex'] + 1 # increment index
|
|
if index > 255: # maximum value of the index
|
|
index = 0 # overflow from 255 to 0
|
|
self._dbusservice['/UpdateIndex'] = index
|
|
|
|
#update lastupdate vars
|
|
self._lastUpdate = time.time()
|
|
except Exception as e:
|
|
logging.critical('Error at %s', '_update', exc_info=e)
|
|
|
|
# return true, otherwise add_timeout will be removed from GObject - see docs http://library.isr.ist.utl.pt/docs/pygtk2reference/gobject-functions.html#function-gobject--timeout-add
|
|
return True
|
|
|
|
def _handlechangedvalue(self, path, value):
|
|
logging.debug("someone else updated %s to %s" % (path, value))
|
|
return True # accept the change
|
|
|
|
|
|
|
|
def main():
|
|
#configure logging
|
|
logging.basicConfig( format='%(asctime)s,%(msecs)d %(name)s %(levelname)s %(message)s',
|
|
datefmt='%Y-%m-%d %H:%M:%S',
|
|
level=logging.INFO,
|
|
handlers=[
|
|
logging.FileHandler("%s/current.log" % (os.path.dirname(os.path.realpath(__file__)))),
|
|
logging.StreamHandler()
|
|
])
|
|
|
|
try:
|
|
logging.info("Start");
|
|
|
|
from dbus.mainloop.glib import DBusGMainLoop
|
|
# Have a mainloop, so we can send/receive asynchronous calls to and from dbus
|
|
DBusGMainLoop(set_as_default=True)
|
|
|
|
#formatting
|
|
_kwh = lambda p, v: (str(round(v, 2)) + 'KWh')
|
|
_a = lambda p, v: (str(round(v, 1)) + 'A')
|
|
_w = lambda p, v: (str(round(v, 1)) + 'W')
|
|
_v = lambda p, v: (str(round(v, 1)) + 'V')
|
|
|
|
#start our main-service
|
|
pvac_output = DbusGoeChargerService(
|
|
servicename='com.victronenergy.evcharger',
|
|
paths=[
|
|
'/Ac/Power': {'initial': 0, 'textformat': _w},
|
|
'/Ac/L1/Power': {'initial': 0, 'textformat': _w},
|
|
'/Ac/L2/Power': {'initial': 0, 'textformat': _w},
|
|
'/Ac/L3/Power': {'initial': 0, 'textformat': _w},
|
|
'/Ac/Energy/Forward': {'initial': 0, 'textformat': _kwh},
|
|
|
|
'/Ac/Voltage': {'initial': 0, 'textformat': _v},
|
|
'/Current': {'initial': 0, 'textformat': _a},
|
|
'/MaxCurrent': {'initial': 0, 'textformat': _a}
|
|
],
|
|
paths={
|
|
'/Ac/Energy/Forward': {'initial': 0, 'textformat': _kwh},
|
|
'/Ac/Power': {'initial': 0, 'textformat': _w},
|
|
|
|
'/Ac/Current': {'initial': 0, 'textformat': _a},
|
|
'/Ac/Voltage': {'initial': 0, 'textformat': _v},
|
|
|
|
'/Ac/L1/Voltage': {'initial': 0, 'textformat': _v},
|
|
'/Ac/L2/Voltage': {'initial': 0, 'textformat': _v},
|
|
'/Ac/L3/Voltage': {'initial': 0, 'textformat': _v},
|
|
'/Ac/L1/Current': {'initial': 0, 'textformat': _a},
|
|
'/Ac/L2/Current': {'initial': 0, 'textformat': _a},
|
|
'/Ac/L3/Current': {'initial': 0, 'textformat': _a},
|
|
'/Ac/L1/Power': {'initial': 0, 'textformat': _w},
|
|
'/Ac/L2/Power': {'initial': 0, 'textformat': _w},
|
|
'/Ac/L3/Power': {'initial': 0, 'textformat': _w},
|
|
'/Ac/L1/Energy/Forward': {'initial': 0, 'textformat': _kwh},
|
|
'/Ac/L2/Energy/Forward': {'initial': 0, 'textformat': _kwh},
|
|
'/Ac/L3/Energy/Forward': {'initial': 0, 'textformat': _kwh},
|
|
})
|
|
|
|
logging.info('Connected to dbus, and switching over to gobject.MainLoop() (= event based)')
|
|
mainloop = gobject.MainLoop()
|
|
mainloop.run()
|
|
except Exception as e:
|
|
logging.critical('Error at %s', 'main', exc_info=e)
|
|
if __name__ == "__main__":
|
|