@ -535,6 +535,63 @@ void Measurements::validateChannel(int ch) {
}
}
float Measurements::getCorrectedTempHum(AirGradient &ag, Configuration &config,
MeasurementType type, int ch, bool forceCorrection) {
// Sanity check to validate channel, assert if invalid
validateChannel(ch);
// Follow array indexing just for get address of the value type
ch = ch - 1;
bool undefined = false;
float rawValue;
Configuration::TempHumCorrection correction;
switch (type) {
case Temperature: {
rawValue = _temperature[ch].update.avg;
Configuration::TempHumCorrection tmp = config.getTempCorrection();
if (tmp.algorithm == TempHumCorrectionAlgorithm::CA_TH_AG_PMS5003T_2024 || forceCorrection) {
return ag.pms5003t_1.compensateTemp(rawValue);
}
correction.algorithm = tmp.algorithm;
correction.intercept = tmp.intercept;
correction.scalingFactor = tmp.scalingFactor;
break;
}
case Humidity: {
rawValue = _humidity[ch].update.avg;
Configuration::TempHumCorrection tmp = config.getHumCorrection();
if (tmp.algorithm == TempHumCorrectionAlgorithm::CA_TH_AG_PMS5003T_2024 || forceCorrection) {
return ag.pms5003t_1.compensateHum(rawValue);
}
correction.algorithm = tmp.algorithm;
correction.intercept = tmp.intercept;
correction.scalingFactor = tmp.scalingFactor;
break;
}
default:
// Should not be called for other measurements
delay(1000);
assert(0);
}
// Use raw if correction not defined
if (correction.algorithm == TempHumCorrectionAlgorithm::CA_TH_NONE ||
correction.algorithm == TempHumCorrectionAlgorithm::CA_TH_UNKNOWN) {
return rawValue;
}
// Custom correction constants
float corrected = (rawValue * correction.scalingFactor) + correction.intercept;
return corrected;
}
float Measurements::getCorrectedPM25(AirGradient &ag, Configuration &config, bool useAvg, int ch) {
float pm25;
float corrected;

View File

@ -123,6 +123,9 @@ public:
*/
float getAverage(MeasurementType type, int ch = 1);
float getCorrectedTempHum(AirGradient &ag, Configuration &config, MeasurementType type,
int ch = 1, bool forceCorrection = false);
/**
* @brief Get the Corrected PM25 object based on the correction algorithm from configuration
*