7.1 KiB
Local Server API
From firmware version 3.0.10 onwards, the AirGradient ONE and Open Air monitors have below API available.
Discovery
The monitors run a mDNS discovery. So within the same network, the monitor can be accessed through:
http://airgradient_{{serialnumber}}.local
The following requests are possible:
Get Current Air Quality (GET)
With the path "/measures/current" you can get the current air quality data.
http://airgradient_ecda3b1eaaaf.local/measures/current
“ecda3b1eaaaf” being the serial number of your monitor.
You get the following response:
{
"wifi": -46,
"serialno": "ecda3b1eaaaf",
"rco2": 447,
"pm01": 3,
"pm02": 7,
"pm10": 8,
"pm003Count": 442,
"atmp": 25.87,
"rhum": 43,
"tvocIndex": 100,
"tvoc_raw": 33051,
"noxIndex": 1,
"nox_raw": 16307,
"boot": 6,
"ledMode": "pm",
"firmwareVersion": "3.0.10beta",
"fwMode": "I-9PSL"
}
Properties | Type | Explanation |
---|---|---|
serialno | String | Serial Number of the monitor |
wifi | Number | WiFi signal strength |
pm01, pm02, pm10 | Number | PM1, PM2.5 and PM10 in ug/m3 |
rco2 | Number | CO2 in ppm |
pm003Count | Number | Particle count per dL |
atmp | Number | Temperature in Degrees Celcius |
rhum | Number | Relative Humidity |
tvocIndex | Number | Senisiron VOC Index |
tvoc_raw | Number | VOC raw value |
noxIndex | Number | Senisirion NOx Index |
nox_raw | Number | NOx raw value |
boot | Number | Counts every measurement cycle. Low boot counts indicate restarts. |
ledMode | String | Current configuration of the LED mode |
firmwareVersion | String | Current firmware version |
fwMode | String | Current model name |
Get Configuration Parameters (GET)
With the path "/config" you can get the current configuration.
{
"country": "US",
"pmStandard": "ugm3",
"ledBarMode": "pm",
"displayMode": "on",
"abcDays": 30,
"tvocLearningOffset": 12,
"noxLearningOffset": 12,
"mqttBrokerUrl": "",
"temperatureUnit": "f",
"configurationControl": "both",
"postDataToAirGradient": true
}
Set Configuration Parameters (PUT)
Configuration parameters can be changed with a put request to the monitor, e.g.
Example to force CO2 calibration
curl -X PUT -H "Content-Type: application/json" -d '{"co2CalibrationRequested":true}' http://airgradient_84fce612eff4.local/config
Example to set monitor to Celsius
curl -X PUT -H "Content-Type: application/json" -d '{"temperatureUnit":"c"}' http://airgradient_84fce612eff4.local/config
Avoiding Conflicts with Configuration on AirGradient Server
If the monitor is set up on the AirGradient dashboard, it will also receive configurations from there. In case you do not want this, please set configurationControl
to local
. In case you set it to cloud
and want to change it to local
, you need to make a factory reset.
Configuration Parameters (GET/PUT)
Properties | Description | Type | Accepted Values | Example |
---|---|---|---|---|
country | Country where the device is. | String | Country code as ALPHA-2 notation | {"country": "TH"} |
pmStandard | Particle matter standard used on the display. | String | ugm3 : ug/m3 us-aqi : USAQI |
{"pmStandard": "ugm3"} |
ledBarMode | Mode in which the led bar can be set. | String | co2 : LED bar displays CO2 pm : LED bar displays PM off : Turn off LED bar |
{"ledBarMode": "off"} |
abcDays | Number of days for CO2 automatic baseline calibration. | Number | Maximum 200 days. Default 8 days. | {"abcDays": 8} |
mqttBrokerUrl | MQTT broker URL. | String | {"mqttBrokerUrl": "mqtt://192.168.0.18:1883"} | |
temperatureUnit | Temperature unit shown on the display. | String | c or C : Degree Celsius °C f or F : Degree Fahrenheit °F |
{"temperatureUnit": "c"} |
configurationControl | The configuration source of the device. | String | both : Accept local and cloud configuration local : Accept only local configuration cloud : Accept only cloud configuration |
{"configurationControl": "both"} |
postDataToAirGradient | Send data to AirGradient cloud. | Boolean | true : Enabled false : Disabled |
{"postDataToAirGradient": true} |
co2CalibrationRequested | Can be set to trigger a calibration. | Boolean | true : CO2 calibration (400ppm) will be triggered |
{"co2CalibrationRequested": true} |
ledBarTestRequested | Can be set to trigger a test. | Boolean | true : LEDs will run test sequence |
{"ledBarTestRequested": true} |