forked from vikt0rm/dbus-goecharger
Implement fetching data from go-e controller
This commit is contained in:
@@ -47,14 +47,9 @@ class DbusGoeControllerService:
|
||||
self._dbusservice.add_path('/DeviceInstance', deviceinstance)
|
||||
self._dbusservice.add_path('/ProductId', 0xFFFF) #
|
||||
self._dbusservice.add_path('/ProductName', productname)
|
||||
self._dbusservice.add_path('/CustomName', productname)
|
||||
self._dbusservice.add_path('/CustomName', productname)
|
||||
if data:
|
||||
fwv = data['fwv']
|
||||
try:
|
||||
fwv = int(data['fwv'].replace('.', ''))
|
||||
except:
|
||||
pass
|
||||
self._dbusservice.add_path('/FirmwareVersion', fwv)
|
||||
self._dbusservice.add_path('/FirmwareVersion', data['fwv'])
|
||||
self._dbusservice.add_path('/Serial', data['sse'])
|
||||
self._dbusservice.add_path('/Connected', 1)
|
||||
self._dbusservice.add_path('/UpdateIndex', 0)
|
||||
@@ -101,7 +96,7 @@ class DbusGoeControllerService:
|
||||
accessType = config['DEFAULT']['AccessType']
|
||||
|
||||
if accessType == 'OnPremise':
|
||||
URL = "http://%s/api/status" % (config['ONPREMISE']['Host'])
|
||||
URL = "http://%s/api/status?filter=sse,ccn,ccp,cpc,cec,usv,fwv" % (config['ONPREMISE']['Host'])
|
||||
else:
|
||||
raise ValueError("AccessType %s is not supported" % (config['DEFAULT']['AccessType']))
|
||||
|
||||
@@ -173,47 +168,25 @@ class DbusGoeControllerService:
|
||||
data = self._getGoeControllerData()
|
||||
|
||||
if data is not None:
|
||||
#send data to DBus
|
||||
self._dbusservice['/Ac/L1/Power'] = int(data['nrg'][7] * 0.1 * 1000)
|
||||
self._dbusservice['/Ac/L2/Power'] = int(data['nrg'][8] * 0.1 * 1000)
|
||||
self._dbusservice['/Ac/L3/Power'] = int(data['nrg'][9] * 0.1 * 1000)
|
||||
self._dbusservice['/Ac/Power'] = int(data['nrg'][11] * 0.01 * 1000)
|
||||
self._dbusservice['/Ac/Voltage'] = int(data['nrg'][0])
|
||||
self._dbusservice['/Current'] = max(data['nrg'][4] * 0.1, data['nrg'][5] * 0.1, data['nrg'][6] * 0.1)
|
||||
self._dbusservice['/Ac/Energy/Forward'] = int(float(data['eto']) / 10.0)
|
||||
|
||||
self._dbusservice['/StartStop'] = int(data['alw'])
|
||||
self._dbusservice['/SetCurrent'] = int(data['amp'])
|
||||
self._dbusservice['/MaxCurrent'] = int(data['ama'])
|
||||
|
||||
# update chargingTime, increment charge time only on active charging (2), reset when no car connected (1)
|
||||
timeDelta = time.time() - self._lastUpdate
|
||||
if int(data['car']) == 2 and self._lastUpdate > 0: # vehicle loads
|
||||
self._chargingTime += timeDelta
|
||||
elif int(data['car']) == 1: # charging station ready, no vehicle
|
||||
self._chargingTime = 0
|
||||
self._dbusservice['/ChargingTime'] = int(self._chargingTime)
|
||||
#send data to DBush
|
||||
grid_category_index = 1
|
||||
self._dbusservice['/Ac/L1/Current'] = data['cpc'][grid_category_index][0]
|
||||
self._dbusservice['/Ac/L2/Current'] = data['cpc'][grid_category_index][1]
|
||||
self._dbusservice['/Ac/L3/Current'] = data['cpc'][grid_category_index][2]
|
||||
|
||||
self._dbusservice['/Mode'] = 0 # Manual, no control
|
||||
|
||||
config = self._getConfig()
|
||||
self._dbusservice['/MCU/Temperature'] = int(data['tma'][0])
|
||||
self._dbusservice['/Ac/Power'] = data['ccp'][grid_category_index]
|
||||
|
||||
# value 'car' 1: charging station ready, no vehicle 2: vehicle loads 3: Waiting for vehicle 4: Charge finished, vehicle still connected
|
||||
status = 0
|
||||
if int(data['car']) == 1:
|
||||
status = 0
|
||||
elif int(data['car']) == 2:
|
||||
status = 2
|
||||
elif int(data['car']) == 3:
|
||||
status = 6
|
||||
elif int(data['car']) == 4:
|
||||
status = 3
|
||||
self._dbusservice['/Status'] = status
|
||||
self._dbusservice['/Ac/L1/Voltage'] = data['usv'][0]['u1']
|
||||
self._dbusservice['/Ac/L2/Voltage'] = data['usv'][0]['u2']
|
||||
self._dbusservice['/Ac/L3/Voltage'] = data['usv'][0]['u3']
|
||||
self._dbusservice['/Ac/N/Voltage'] = data['usv'][0]['uN']
|
||||
|
||||
self._dbusservice['/Ac/Energy/Forward'] = data['cec'][grid_category_index][0] / 1000.
|
||||
self._dbusservice['/Ac/Energy/Backward'] = data['cec'][grid_category_index][1] / 1000.
|
||||
|
||||
#logging
|
||||
logging.debug("Wallbox Consumption (/Ac/Power): %s" % (self._dbusservice['/Ac/Power']))
|
||||
logging.debug("Wallbox Forward (/Ac/Energy/Forward): %s" % (self._dbusservice['/Ac/Energy/Forward']))
|
||||
logging.debug("Smartmeter Consumption (/Ac/Power): %s" % (self._dbusservice['/Ac/Power']))
|
||||
logging.debug("Smartmeter Forward (/Ac/Energy/Forward): %s" % (self._dbusservice['/Ac/Energy/Forward']))
|
||||
logging.debug("---")
|
||||
|
||||
# increment UpdateIndex - to show that new data is available
|
||||
@@ -274,24 +247,21 @@ def main():
|
||||
|
||||
#start our main-service
|
||||
pvac_output = DbusGoeControllerService(
|
||||
servicename='com.victronenergy.evcharger',
|
||||
servicename='com.victronenergy.grid',
|
||||
paths={
|
||||
'/Ac/L1/Current': {'initial': 0, 'textformat': _a},
|
||||
'/Ac/L2/Current': {'initial': 0, 'textformat': _a},
|
||||
'/Ac/L3/Current': {'initial': 0, 'textformat': _a},
|
||||
'/Ac/Power': {'initial': 0, 'textformat': _w},
|
||||
'/Ac/L1/Power': {'initial': 0, 'textformat': _w},
|
||||
'/Ac/L2/Power': {'initial': 0, 'textformat': _w},
|
||||
'/Ac/L3/Power': {'initial': 0, 'textformat': _w},
|
||||
'/Ac/L1/Voltage': {'initial': 0, 'textformat': _v},
|
||||
'/Ac/L2/Voltage': {'initial': 0, 'textformat': _v},
|
||||
'/Ac/L3/Voltage': {'initial': 0, 'textformat': _v},
|
||||
'/Ac/N/Voltage': {'initial': 0, 'textformat': _v},
|
||||
'/Ac/Energy/Forward': {'initial': 0, 'textformat': _kwh},
|
||||
'/ChargingTime': {'initial': 0, 'textformat': _s},
|
||||
|
||||
'/Ac/Voltage': {'initial': 0, 'textformat': _v},
|
||||
'/Current': {'initial': 0, 'textformat': _a},
|
||||
'/SetCurrent': {'initial': 0, 'textformat': _a},
|
||||
'/MaxCurrent': {'initial': 0, 'textformat': _a},
|
||||
'/MCU/Temperature': {'initial': 0, 'textformat': _degC},
|
||||
'/StartStop': {'initial': 0, 'textformat': lambda p, v: (str(v))}
|
||||
'/Ac/Energy/Backward': {'initial': 0, 'textformat': _kwh},
|
||||
}
|
||||
)
|
||||
|
||||
)
|
||||
|
||||
logging.info('Connected to dbus, and switching over to gobject.MainLoop() (= event based)')
|
||||
mainloop = gobject.MainLoop()
|
||||
mainloop.run()
|
||||
|
Reference in New Issue