forked from espressif/esp-modbus
fix slave id handling in master and slave
This commit is contained in:
@ -53,11 +53,11 @@
|
||||
|
||||
#if MB_FUNC_OTHER_REP_SLAVEID_ENABLED
|
||||
|
||||
#define MB_PDU_FUNC_READ_BYTECNT_OFF ( MB_PDU_DATA_OFF + 0 )
|
||||
#define MB_PDU_FUNC_READ_VALUES_OFF ( MB_PDU_DATA_OFF + 1 )
|
||||
#define MB_PDU_BYTECNT_OFF ( MB_PDU_DATA_OFF + 0 )
|
||||
#define MB_PDU_FUNC_DATA_OFF ( MB_PDU_DATA_OFF + 1 )
|
||||
|
||||
/* ----------------------- Static variables ---------------------------------*/
|
||||
static UCHAR ucMBSlaveID[MB_FUNC_OTHER_REP_SLAVEID_BUF];
|
||||
static UCHAR ucMBSlaveID[MB_FUNC_OTHER_REP_SLAVEID_BUF] = {0};
|
||||
static USHORT usMBSlaveIDLen;
|
||||
|
||||
/* ----------------------- Start implementation -----------------------------*/
|
||||
@ -92,9 +92,9 @@ eMBMasterFuncReportSlaveID( UCHAR * pucFrame, USHORT * usLen )
|
||||
|
||||
if( *usLen <= ( MB_FUNC_OTHER_REP_SLAVEID_BUF - 2 ) )
|
||||
{
|
||||
ucByteCount = ( UCHAR )( pucFrame[MB_PDU_FUNC_READ_BYTECNT_OFF] );
|
||||
ESP_LOGW("TEST", "Handle slave info command.");
|
||||
eRegStatus = eMBMasterRegInputCB( &pucFrame[MB_PDU_FUNC_READ_VALUES_OFF], 0, (ucByteCount >> 1) );
|
||||
ucByteCount = ( UCHAR )( pucFrame[MB_PDU_BYTECNT_OFF] );
|
||||
ESP_LOGD("FHANDLER_SET_SLAVE_ID", "Master handler of slave info command %u bytes.", ucByteCount);
|
||||
eRegStatus = eMBMasterRegInputCB( &pucFrame[MB_PDU_FUNC_DATA_OFF], 0, (ucByteCount >> 1) );
|
||||
/* If an error occured convert it into a Modbus exception. */
|
||||
if( eRegStatus != MB_ENOERR )
|
||||
{
|
||||
@ -129,6 +129,7 @@ eMBSetSlaveID( UCHAR ucSlaveID, BOOL xIsRunning,
|
||||
( size_t )usAdditionalLen );
|
||||
usMBSlaveIDLen += usAdditionalLen;
|
||||
}
|
||||
ESP_LOG_BUFFER_HEX_LEVEL("FHANDLER_SET_SLAVE_ID", (void*)ucMBSlaveID, usMBSlaveIDLen, ESP_LOG_DEBUG);
|
||||
}
|
||||
else
|
||||
{
|
||||
@ -137,11 +138,14 @@ eMBSetSlaveID( UCHAR ucSlaveID, BOOL xIsRunning,
|
||||
return eStatus;
|
||||
}
|
||||
|
||||
// pucFrame points to Modbus PDU
|
||||
eMBException
|
||||
eMBFuncReportSlaveID( UCHAR * pucFrame, USHORT * usLen )
|
||||
{
|
||||
memcpy( &pucFrame[MB_PDU_DATA_OFF], &ucMBSlaveID[0], ( size_t )usMBSlaveIDLen );
|
||||
*usLen = ( USHORT )( MB_PDU_DATA_OFF + usMBSlaveIDLen );
|
||||
memcpy( &pucFrame[MB_PDU_FUNC_DATA_OFF], &ucMBSlaveID[0], ( size_t )usMBSlaveIDLen );
|
||||
*usLen = ( USHORT )( MB_PDU_FUNC_DATA_OFF + usMBSlaveIDLen );
|
||||
pucFrame[MB_PDU_BYTECNT_OFF] = usMBSlaveIDLen;
|
||||
ESP_LOG_BUFFER_HEX_LEVEL("REPORT_SLAVE_ID_FRAME", (void*)pucFrame, *usLen, ESP_LOG_DEBUG);
|
||||
return MB_EX_NONE;
|
||||
}
|
||||
|
||||
|
@ -494,7 +494,7 @@ static esp_err_t mbc_serial_master_set_parameter(uint16_t cid, char* name, uint8
|
||||
*/
|
||||
// Callback function for reading of MB Input Registers
|
||||
eMBErrorCode eMBRegInputCBSerialMaster(UCHAR * pucRegBuffer, USHORT usAddress,
|
||||
USHORT usNRegs)
|
||||
USHORT usNRegs)
|
||||
{
|
||||
MB_MASTER_CHECK((mbm_interface_ptr != NULL),
|
||||
MB_EILLSTATE,
|
||||
@ -510,7 +510,7 @@ eMBErrorCode eMBRegInputCBSerialMaster(UCHAR * pucRegBuffer, USHORT usAddress,
|
||||
// If input or configuration parameters are incorrect then return an error to stack layer
|
||||
if ((pucInputBuffer != NULL)
|
||||
&& (usNRegs >= 1)
|
||||
&& (usRegInputNregs == usRegs)) {
|
||||
&& ((usRegInputNregs == usRegs) || !usAddress)) {
|
||||
while (usRegs > 0) {
|
||||
_XFER_2_RD(pucInputBuffer, pucRegBuffer);
|
||||
usRegs -= 1;
|
||||
|
@ -305,26 +305,22 @@ static void master_operation_func(void *arg)
|
||||
|
||||
ESP_LOGI(TAG, "Start modbus test...");
|
||||
|
||||
mb_param_request_t req = {0};
|
||||
|
||||
uint8_t info_buf[64] = {0};
|
||||
|
||||
// Command - 17 (0x11) Report Slave ID (Serial Line only)
|
||||
req.command = 0x11;
|
||||
// The command contains vendor specific data.
|
||||
// This version of command handler needs to define expected number of registers
|
||||
// that will be returned from concrete slave.
|
||||
// The returned slave info data will be stored in the `info_buf`.
|
||||
req.reg_size = 16;
|
||||
// This example will reques the slave infor from slave UID = 1.
|
||||
// This example will request the slave info from slave UID = 1.
|
||||
// It can be modified accordingly for other slaves.
|
||||
req.slave_addr = 0x01;
|
||||
mb_param_request_t req = {.slave_addr = 1, .command = 0x11, .reg_start = 1, .reg_size = 16};
|
||||
|
||||
uint8_t info_buf[32] = {0};
|
||||
|
||||
err = mbc_master_send_request(&req, &info_buf[0]);
|
||||
if (err != ESP_OK) {
|
||||
ESP_LOGE("SLAVE_INFO", "Read slave info fail.");
|
||||
} else {
|
||||
ESP_LOGI("SLAVE_INFO", "Slave ID array: %" PRIX32, *(uint32_t*)&info_buf[0]);
|
||||
ESP_LOG_BUFFER_HEX_LEVEL("SLAVE_INFO", (void*)info_buf, sizeof(info_buf), ESP_LOG_WARN);
|
||||
}
|
||||
|
||||
for(uint16_t retry = 0; retry <= MASTER_MAX_RETRY && (!alarm_state); retry++) {
|
||||
|
@ -126,6 +126,10 @@ static void setup_reg_data(void)
|
||||
input_reg_params.input_data7 = 4.78;
|
||||
}
|
||||
|
||||
extern int
|
||||
eMBSetSlaveID(uint8_t slave_id, bool is_running,
|
||||
uint8_t const *pdata, uint16_t data_len);
|
||||
|
||||
// An example application of Modbus slave. It is based on freemodbus stack.
|
||||
// See deviceparams.h file for more information about assigned Modbus parameters.
|
||||
// These parameters can be accessed from main application and also can be changed
|
||||
@ -226,6 +230,17 @@ void app_main(void)
|
||||
ESP_LOGI(TAG, "Modbus slave stack initialized.");
|
||||
ESP_LOGI(TAG, "Start modbus test...");
|
||||
|
||||
//const uint32_t ext_data = 0x11223344;
|
||||
uint8_t ext_data[] = {0x11, 0x22, 0x33, 0x44, 0x55};
|
||||
|
||||
int err = eMBSetSlaveID(comm_info.slave_addr, true, (uint8_t *)&ext_data, sizeof(ext_data));
|
||||
if (!err) {
|
||||
//ESP_LOGI("SET_SLAVE_ID", "Set slave ID = %d, ext_data=0x%" PRIx32, comm_info.slave_addr, ext_data);
|
||||
ESP_LOG_BUFFER_HEX_LEVEL("SET_SLAVE_ID", (void*)ext_data, sizeof(ext_data), ESP_LOG_WARN);
|
||||
} else {
|
||||
ESP_LOGE("SET_SLAVE_ID", "Set slave ID fail, err=%d.", err);
|
||||
}
|
||||
|
||||
// The cycle below will be terminated when parameter holdingRegParams.dataChan0
|
||||
// incremented each access cycle reaches the CHAN_DATA_MAX_VAL value.
|
||||
for(;holding_reg_params.holding_data0 < MB_CHAN_DATA_MAX_VAL;) {
|
||||
|
Reference in New Issue