Merge pull request #10047 from rook/mergify/bp/release-1.9/pr-9903
csi: update multus design to mitigate csi-plugin pod restart (backport #9903)
This commit is contained in:
1 file changed
+33
-92
@@ -90,111 +90,52 @@ interface will be added to the host network namespace for all nodes that will ru
|
||||
This will allow Ceph CSI pods to run using host networking and still access Ceph's public multus
|
||||
network.
|
||||
|
||||
The design for mitigating the issue is comprised of two components: a "holder" DaemonSet and a
|
||||
"mover" Daemonset.
|
||||
The design for mitigating the issue is to add a new DaemonSet that will own the network for all CephFS mounts
|
||||
as well as RBD mapped devices. The `csi-{cephfs,rbd}plugin` DaemonSet are left untouched.
|
||||
|
||||
#### Holder DaemonSet and Pods
|
||||
The Rook-Ceph Operator's CSI controller creates a DaemonSet configured to use the
|
||||
#### New "holder" DaemonSet
|
||||
The Rook-Ceph Operator's CSI controller creates a `csi-plugin-holder` DaemonSet configured to use the
|
||||
`network.selectors.public` network specified for the CephCluster. This DaemonSet runs on all the
|
||||
nodes that will have CSI plugin pods. Its pods exist to "hold" a particular network interface that
|
||||
the CSI pods can reliably connect to for communication with the Ceph cluster. The process running
|
||||
will merely be an infinite sleep.
|
||||
nodes along side the `csi-{cephfs,rbd}plugin` DaemonSet.
|
||||
|
||||
These Pods should only be stopped and restarted when a node is stopped so that volume operations do
|
||||
This Pod should only be stopped and restarted when a node is stopped so that volume operations do
|
||||
not become blocked. The Rook-Ceph Operator's CSI controller should set the DaemonSet's update
|
||||
strategy to `OnDelete` so that the pods do not get deleted if the DaemonSet is updated while also
|
||||
ensuring that the pods will be updated on the next node reboot (or node drain).
|
||||
|
||||
#### Mover DaemonSet and Pods
|
||||
The Rook-Ceph Operator's CSI controller also creates a second DaemonSet configured to use host
|
||||
networking. This DaemonSet also runs on all nodes that will have CSI plugin pods (and holder pods).
|
||||
Mover pods exist to "move" the multus network interface being held by the holder pod on the node
|
||||
into the host's network namespace to provide user's volumes with uninterrupted access to the Ceph
|
||||
cluster, even when the CSI driver is restarted (or updated).
|
||||
The new holder DaemonSet only contains a single container called `holder`, the container
|
||||
responsible for pinning the network for filesystem mounts and mapped block devices. It is used as a passthrough by
|
||||
the Ceph-CSI plugin pod which when mounting or mapping will use the network namespace of that holder
|
||||
pod.
|
||||
|
||||
The mover must:
|
||||
- be a privileged container
|
||||
- have `SYS_ADMIN` and `NET_ADMIN` capabilities
|
||||
- be on the host network namespace
|
||||
- have access to the `/var/run/netns` directory
|
||||
|
||||
In order to not leave moved interfaces dangling in the host's network namespace, mover pods must
|
||||
move interfaces back to their original namespace when CSI is being terminated. The most
|
||||
straightforward way to accomplish this is to move interfaces back when the mover is being
|
||||
terminated. If an interface is moved without user applications also being removed, this will cause
|
||||
I/O disruption. Therefore, the DaemonSet should also use the `OnDelete` update strategy so that the
|
||||
pods can be updated on node reboots (or node drains).
|
||||
|
||||
In order to better handle unexpected corner cases that leave moved interfaces in the host network
|
||||
namespace (e.g., a mover is killed abruptly rather than gracefully terminated), instead treat "move"
|
||||
operations as a disable-and-copy operation. To do this, disable the interface in the holder pod's
|
||||
network namespace, and create a copy of the interface in the host namespace with the same MAC
|
||||
address and IP config. From the user standpoint, the interface is still "moved" because the original
|
||||
is disabled, so we keep the "mover" terminology. This merely helps Rook ensure that it is not
|
||||
accidentally losing the original information.
|
||||
|
||||
A previous iteration of this design specified the mover application as a sidecar to Ceph CSI plugin
|
||||
pods; however, this design would mean that the mover would need to be deleted and re-created
|
||||
whenever the CSI plugin is updated, possibly resulting in I/O hangs in user pods during the update.
|
||||
Keeping the mover independent allows CSI plugin updates to happen freely without complex
|
||||
interactions between it and the mover.
|
||||
One task of the Holder container is to pass the required PID into the `csi-plugin` pod. To
|
||||
solve this, the container will create a symlink to an equivalent of `/proc/$$/ns/net` in the
|
||||
`hostPath` volume shared with the `csi-plugin` pod. Then it will sleep forever.
|
||||
In order to support multiple Ceph-CSI consuming multiple Ceph clusters, the name of the symlink should be based on the Ceph
|
||||
cluster FSID. The complete name of the symlink can be decided during the implementation phase of the
|
||||
design.
|
||||
That symlink name will be stored in the Ceph-CSI configmap with a key name that we will define
|
||||
during the implementation.
|
||||
|
||||
#### Interactions between components
|
||||
If a copied interface is left in the host network namespace after the holder pod is removed, multus
|
||||
may later give the address to a different application, and the CSI driver may try to connect to the
|
||||
different application with Ceph requests. We should try to avoid leaving interfaces on the host as
|
||||
much as possible. Killing the mover pod abruptly will leave copied interfaces, but there is no way
|
||||
to prevent this from happening.
|
||||
When the Ceph-CSI plugin mounts or maps a block device it will use the network namespace of the
|
||||
Holder pod. This is achieved by using `nsenter` to enter the network namespace of the Holder pod.
|
||||
Some changes are expected as part of the mounting/mapping method in today's `csi-plugin` pod.
|
||||
Instead of invoking `rbd map ...`, invoke `nsenter --net=<net
|
||||
ns file of pause in long-running pod> rbd map ...` (and same for `mount -t ceph ...`). The `csi-plugin`
|
||||
pod is already privileged, it already adds `CAP_SYS_ADMIN`. The only missing piece is to expose the host
|
||||
PID namespace with `hostPID: true` on the `csi-cephfsplugin` DaemonSet (RBD already has it).
|
||||
|
||||
If a holder pod is deleted, the interface hold will be lost. The mover must remove the
|
||||
interface from the host's network namespace because multus may reassign the address to a different
|
||||
application. We can document for users that they should not delete holder pods, but we cannot
|
||||
prevent users from manually stopping holder pods. However, to prevent the Kubernetes scheduler from
|
||||
terminating holder pods, the pods should be given the highest possible priority so that they are not
|
||||
un-scheduled except by users.
|
||||
Cleaning up the symlink is not a requirement nor a big issue. Once the Holder container stops, its
|
||||
network namespace goes away with it. So at worst, we end up with a broken symlink.
|
||||
|
||||
There is a possible race condition where a mover pod is killed and where a holder is deleted before
|
||||
a new mover starts up. In this case, the copied interface for the holder pod will be left in the
|
||||
host network namespace, but the mover will not get a notification that the holder was removed. In
|
||||
order to clean up from this case, upon startup, the mover should delete all interface copies in the
|
||||
host network namespace that do not have a holder pod associated with them.
|
||||
When a new node is added, both DaemonSets are started, and the
|
||||
process described above occurs on the node.
|
||||
|
||||
If the mover container is stopped, it should delete all copied interfaces in the host's
|
||||
network namespace under the assumption that the CSI plugin is being removed, possibly by a
|
||||
CephCluster being deleted or the node going down for maintenance. It might be possible to optimize
|
||||
for the case where only the mover pod is being restarted, but it is very difficult to detect the
|
||||
case where the mover is merely being restarted versus when the holder is also being removed without
|
||||
possible race conditions between which pod might be stopped first by the Kubernetes API server
|
||||
during a drain event. Therefore, focus on the simplest working implementation (described above)
|
||||
instead of risking leaving the interface copy in host net namespace which could cause issues.
|
||||
|
||||
If an error occurs in the mover during network migration, it will fail and re-try migration until
|
||||
the operation succeeds. If necessary, the mover will try to remove a partially-copied interface.
|
||||
|
||||
Restarting a node will cause the multus interface in the host namespace to go away. On restart, the
|
||||
holder pod will get a new interface, and the mover will copy it into the host networking namespace again.
|
||||
|
||||
When a new node is added, holder and mover pods are added to it by their DaemonSets, and the
|
||||
move/copy process described above occurs on the node.
|
||||
|
||||
The holder and mover DaemonSets should be deleted when the CSI driver components are removed. Both
|
||||
the termination of the holder pods as well as the mover pods triggers the mover to remove the multus
|
||||
interfaces from the host network namespace of a given node.
|
||||
|
||||
The initial implementation of this design will be limited to supporting a single CephCluster with
|
||||
Multus until we can be sure that the CSI plugin can support multiple migrated interfaces as well as
|
||||
interfaces that are added and removed dynamically. This limitation will be enforced by allowing only
|
||||
a single instance of the holder DaemonSet. A possible (future) partial implementation may be
|
||||
possible by restarting the CSI plugin Pods when network interfaces are added or removed.
|
||||
|
||||
**Known issue:** the Docker container runtime does not use Linux's native `/var/run/netns`
|
||||
directory. This mitigation is known to work on cri-o runtime but not Docker. Therefore, this feature
|
||||
will be disabled by default and enabled optionally by the
|
||||
`ROOK_CSI_MULTUS_USE_HOLDER_MOVER_PATTERN=true` variable in the Rook-Ceph operator's config.
|
||||
|
||||
A previous version of the CSI proposal had the holder Pods creating "setup" and "teardown"
|
||||
Kubernetes Jobs for migrating/un-migrating the multus networks. This design was rejected since new
|
||||
Jobs wouldn't be able to be created if the Kubernetes namespace were in "Terminating" state.
|
||||
The initial implementation of this design is limited to supporting a single CephCluster with
|
||||
Multus.
|
||||
Until we stop using HostNetwork entirely it is impossible to support multiple CephClusters with and
|
||||
without Multus enabled.
|
||||
|
||||
## Accepted proposal
|
||||
|
||||
|
||||