csi: add CSIDriverOptions section in cephCluster CR

This commit adds new CSIDriverOptions section in
cephCluster CR. This section contains settings
for read affinity and kernel+fuse Mount options
These settings will be injected directly into
rook-ceph-csi-config cm to be applicable per
ceph cluster.

Signed-off-by: Rakshith R <rar@redhat.com>
This commit is contained in:
Rakshith R committed 2023-11-29 19:34:28 +05:30
1 parent 580760c8d3
commit 59cb0dd4bf
14 files changed
+530 -18

No files matched your search

+160
View File
@@ -1099,6 +1099,20 @@ LogCollectorSpec
<p>Logging represents loggings settings</p>
</td>
</tr>
<tr>
<td>
<code>csi</code><br/>
<em>
<a href="#ceph.rook.io/v1.CSIDriverSpec">
CSIDriverSpec
</a>
</em>
</td>
<td>
<em>(Optional)</em>
<p>CSI Driver Options applied per cluster.</p>
</td>
</tr>
</table>
</td>
</tr>
@@ -2794,6 +2808,94 @@ case where the range spec is forgotten (e.g., /24). Rook does in-depth validatio
</td>
</tr></tbody>
</table>
<h3 id="ceph.rook.io/v1.CSICephFSSpec">CSICephFSSpec
</h3>
<p>
(<em>Appears on:</em><a href="#ceph.rook.io/v1.CSIDriverSpec">CSIDriverSpec</a>)
</p>
<div>
<p>CSICephFSSpec defines the settings for CephFS CSI driver.</p>
</div>
<table>
<thead>
<tr>
<th>Field</th>
<th>Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<code>kernelMountOptions</code><br/>
<em>
string
</em>
</td>
<td>
<em>(Optional)</em>
<p>KernelMountOptions defines the mount options for kernel mounter.</p>
</td>
</tr>
<tr>
<td>
<code>fuseMountOptions</code><br/>
<em>
string
</em>
</td>
<td>
<em>(Optional)</em>
<p>FuseMountOptions defines the mount options for ceph fuse mounter.</p>
</td>
</tr>
</tbody>
</table>
<h3 id="ceph.rook.io/v1.CSIDriverSpec">CSIDriverSpec
</h3>
<p>
(<em>Appears on:</em><a href="#ceph.rook.io/v1.ClusterSpec">ClusterSpec</a>)
</p>
<div>
<p>CSIDriverSpec defines CSI Driver settings applied per cluster.</p>
</div>
<table>
<thead>
<tr>
<th>Field</th>
<th>Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<code>readAffinity</code><br/>
<em>
<a href="#ceph.rook.io/v1.ReadAffinitySpec">
ReadAffinitySpec
</a>
</em>
</td>
<td>
<em>(Optional)</em>
<p>ReadAffinity defines the read affinity settings for CSI driver.</p>
</td>
</tr>
<tr>
<td>
<code>cephfs</code><br/>
<em>
<a href="#ceph.rook.io/v1.CSICephFSSpec">
CSICephFSSpec
</a>
</em>
</td>
<td>
<em>(Optional)</em>
<p>CephFS defines CSI Driver settings for CephFS driver.</p>
</td>
</tr>
</tbody>
</table>
<h3 id="ceph.rook.io/v1.Capacity">Capacity
</h3>
<p>
@@ -4249,6 +4351,20 @@ LogCollectorSpec
<p>Logging represents loggings settings</p>
</td>
</tr>
<tr>
<td>
<code>csi</code><br/>
<em>
<a href="#ceph.rook.io/v1.CSIDriverSpec">
CSIDriverSpec
</a>
</em>
</td>
<td>
<em>(Optional)</em>
<p>CSI Driver Options applied per cluster.</p>
</td>
</tr>
</tbody>
</table>
<h3 id="ceph.rook.io/v1.ClusterState">ClusterState
@@ -10309,6 +10425,50 @@ optional</p>
</tr>
</tbody>
</table>
<h3 id="ceph.rook.io/v1.ReadAffinitySpec">ReadAffinitySpec
</h3>
<p>
(<em>Appears on:</em><a href="#ceph.rook.io/v1.CSIDriverSpec">CSIDriverSpec</a>)
</p>
<div>
<p>ReadAffinitySpec defines the read affinity settings for CSI driver.</p>
</div>
<table>
<thead>
<tr>
<th>Field</th>
<th>Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<code>enabled</code><br/>
<em>
bool
</em>
</td>
<td>
<em>(Optional)</em>
<p>Enables read affinity for CSI driver.</p>
</td>
</tr>
<tr>
<td>
<code>crushLocationLabels</code><br/>
<em>
[]string
</em>
</td>
<td>
<em>(Optional)</em>
<p>CrushLocationLabels defines which node labels to use
as CRUSH location. This should correspond to the values set in
the CRUSH map.</p>
</td>
</tr>
</tbody>
</table>
<h3 id="ceph.rook.io/v1.ReplicatedSpec">ReplicatedSpec
</h3>
<p>
@@ -249,22 +249,23 @@ OSD locations defined in the CRUSH map and topology labels on nodes.
Refer to the [krbd-options](https://docs.ceph.com/en/latest/man/8/rbd/#kernel-rbd-krbd-options)
for more details.
Execute the following steps:
Execute the following step to enable read affinity for a specific ceph cluster:
* Patch the `rook-ceph-operator-config` configmap using the following
command.
* Patch the ceph cluster CR to enable read affinity:
```console
kubectl patch cm rook-ceph-operator-config -nrook-ceph -p $'data:\n "CSI_ENABLE_READ_AFFINITY": "true"'
kubectl patch cephclusters.ceph.rook.io <cluster-name> -n rook-ceph -p '{"spec":{"csi":{"readAffinity":{"enabled": true}}}}'
```
```yaml
csi:
readAffinity:
enabled: true
```
* Add topology labels to the Kubernetes nodes. The same labels may be used as mentioned in the
[OSD topology](../../CRDs/Cluster/ceph-cluster-crd.md#osd-topology) topic.
* (optional) Rook will pass the labels mentioned in [osd-topology](../../CRDs/Cluster/ceph-cluster-crd.md#osd-topology)
as the default set of labels. This can overridden to supply custom labels by updating the
`CSI_CRUSH_LOCATION_LABELS` value in the `rook-ceph-operator-config` configmap.
Ceph CSI will extract the CRUSH location from the topology labels found on the node
and pass it though krbd options during mapping RBD volumes.
@@ -962,6 +962,32 @@ spec:
description: Disable determines whether we should enable the crash collector
type: boolean
type: object
csi:
description: CSI Driver Options applied per cluster.
properties:
cephfs:
description: CephFS defines CSI Driver settings for CephFS driver.
properties:
fuseMountOptions:
description: FuseMountOptions defines the mount options for ceph fuse mounter.
type: string
kernelMountOptions:
description: KernelMountOptions defines the mount options for kernel mounter.
type: string
type: object
readAffinity:
description: ReadAffinity defines the read affinity settings for CSI driver.
properties:
crushLocationLabels:
description: CrushLocationLabels defines which node labels to use as CRUSH location. This should correspond to the values set in the CRUSH map.
items:
type: string
type: array
enabled:
description: Enables read affinity for CSI driver.
type: boolean
type: object
type: object
dashboard:
description: Dashboard settings
nullable: true
+16
View File
@@ -281,6 +281,22 @@ spec:
# No values or 0 means that the operator will wait until the placement groups are healthy before unblocking the next drain.
pgHealthCheckTimeout: 0
# csi defines CSI Driver settings applied per cluster.
csi:
readAffinity:
# Enable read affinity to enable clients to optimize reads from an OSD in the same topology.
# Enabling the read affinity may cause the OSDs to consume some extra memory.
# For more details see this doc:
# https://rook.io/docs/rook/latest/Storage-Configuration/Ceph-CSI/ceph-csi-drivers/#enable-read-affinity-for-rbd-volumes
enabled: false
# cephfs driver specific settings.
cephfs:
# Set CephFS Kernel mount options to use https://docs.ceph.com/en/latest/man/8/mount.ceph/#options.
# kernelMountOptions: ""
# Set CephFS Fuse mount options to use https://docs.ceph.com/en/quincy/man/8/ceph-fuse/#options.
# fuseMountOptions: ""
# healthChecks
# Valid values for daemons are 'mon', 'osd', 'status'
healthCheck:
+26
View File
@@ -960,6 +960,32 @@ spec:
description: Disable determines whether we should enable the crash collector
type: boolean
type: object
csi:
description: CSI Driver Options applied per cluster.
properties:
cephfs:
description: CephFS defines CSI Driver settings for CephFS driver.
properties:
fuseMountOptions:
description: FuseMountOptions defines the mount options for ceph fuse mounter.
type: string
kernelMountOptions:
description: KernelMountOptions defines the mount options for kernel mounter.
type: string
type: object
readAffinity:
description: ReadAffinity defines the read affinity settings for CSI driver.
properties:
crushLocationLabels:
description: CrushLocationLabels defines which node labels to use as CRUSH location. This should correspond to the values set in the CRUSH map.
items:
type: string
type: array
enabled:
description: Enables read affinity for CSI driver.
type: boolean
type: object
type: object
dashboard:
description: Dashboard settings
nullable: true
+36
View File
@@ -221,6 +221,42 @@ type ClusterSpec struct {
// +optional
// +nullable
LogCollector LogCollectorSpec `json:"logCollector,omitempty"`
// CSI Driver Options applied per cluster.
// +optional
CSI CSIDriverSpec `json:"csi,omitempty"`
}
// CSIDriverSpec defines CSI Driver settings applied per cluster.
type CSIDriverSpec struct {
// ReadAffinity defines the read affinity settings for CSI driver.
// +optional
ReadAffinity ReadAffinitySpec `json:"readAffinity"`
// CephFS defines CSI Driver settings for CephFS driver.
// +optional
CephFS CSICephFSSpec `json:"cephfs,omitempty"`
}
// CSICephFSSpec defines the settings for CephFS CSI driver.
type CSICephFSSpec struct {
// KernelMountOptions defines the mount options for kernel mounter.
// +optional
KernelMountOptions string `json:"kernelMountOptions,omitempty"`
// FuseMountOptions defines the mount options for ceph fuse mounter.
// +optional
FuseMountOptions string `json:"fuseMountOptions,omitempty"`
}
// ReadAffinitySpec defines the read affinity settings for CSI driver.
type ReadAffinitySpec struct {
// Enables read affinity for CSI driver.
// +optional
Enabled bool `json:"enabled"`
// CrushLocationLabels defines which node labels to use
// as CRUSH location. This should correspond to the values set in
// the CRUSH map.
// +optional
CrushLocationLabels []string `json:"crushLocationLabels,omitempty"`
}
// LogCollectorSpec is the logging spec
+1
View File
@@ -48,6 +48,7 @@ type ClusterInfo struct {
name string
OsdUpgradeTimeout time.Duration
NetworkSpec cephv1.NetworkSpec
CSIDriverSpec cephv1.CSIDriverSpec
// A context to cancel the context it is used to determine whether the reconcile loop should
// exist (if the context has been cancelled). This cannot be in main clusterd context since this
// is a pointer passed through the entire life cycle or the operator. If the context is
+5
View File
@@ -220,6 +220,11 @@ func (c *ClusterController) initializeCluster(cluster *cluster) error {
go cluster.reportTelemetry()
}
err := csi.SaveCSIDriverOptions(c.context.Clientset, cluster.Namespace, cluster.ClusterInfo)
if err != nil {
return errors.Wrap(err, "failed to save CSI driver options")
}
// Populate ClusterInfo with the last value
cluster.mons.ClusterInfo = cluster.ClusterInfo
cluster.mons.ClusterInfo.SetName(c.namespacedName.Name)
@@ -32,6 +32,7 @@ import (
cephv1 "github.com/rook/rook/pkg/apis/ceph.rook.io/v1"
"github.com/rook/rook/pkg/clusterd"
cephclient "github.com/rook/rook/pkg/daemon/ceph/client"
"github.com/rook/rook/pkg/operator/ceph/cluster/osd/topology"
"github.com/rook/rook/pkg/operator/k8sutil"
"github.com/rook/rook/pkg/util/exec"
"github.com/rook/rook/pkg/util/sys"
@@ -154,6 +155,12 @@ func CreateOrLoadClusterInfo(clusterdContext *clusterd.Context, context context.
// can run on remote executor
clusterInfo.NetworkSpec = cephClusterSpec.Network
// update clusterInfo with cephClusterSpec.CSI.
clusterInfo.CSIDriverSpec = cephClusterSpec.CSI
if len(clusterInfo.CSIDriverSpec.ReadAffinity.CrushLocationLabels) == 0 {
clusterInfo.CSIDriverSpec.ReadAffinity.CrushLocationLabels = strings.Split(topology.GetDefaultTopologyLabels(), ",")
}
// If an admin key was provided we don't need to load the other resources
// Some people might want to give the admin key
// The necessary users/keys/secrets will be created by Rook
+83 -7
View File
@@ -26,6 +26,7 @@ import (
"github.com/coreos/pkg/capnslog"
"github.com/pkg/errors"
cephv1 "github.com/rook/rook/pkg/apis/ceph.rook.io/v1"
cephclient "github.com/rook/rook/pkg/daemon/ceph/client"
"github.com/rook/rook/pkg/operator/k8sutil"
v1 "k8s.io/api/core/v1"
@@ -40,18 +41,21 @@ var (
)
type CsiClusterConfigEntry struct {
ClusterID string `json:"clusterID"`
Monitors []string `json:"monitors"`
Namespace string `json:"namespace"`
CephFS *CsiCephFSSpec `json:"cephFS,omitempty"`
NFS *CsiNFSSpec `json:"nfs,omitempty"`
RBD *CsiRBDSpec `json:"rbd,omitempty"`
RadosNamespace string `json:"radosNamespace,omitempty"`
ClusterID string `json:"clusterID"`
Monitors []string `json:"monitors"`
Namespace string `json:"namespace"`
CephFS *CsiCephFSSpec `json:"cephFS,omitempty"`
NFS *CsiNFSSpec `json:"nfs,omitempty"`
RBD *CsiRBDSpec `json:"rbd,omitempty"`
RadosNamespace string `json:"radosNamespace,omitempty"`
ReadAffinity *cephv1.ReadAffinitySpec `json:"readAffinity,omitempty"`
}
type CsiCephFSSpec struct {
NetNamespaceFilePath string `json:"netNamespaceFilePath,omitempty"`
SubvolumeGroup string `json:"subvolumeGroup,omitempty"`
KernelMountOptions string `json:"kernelMountOptions,omitempty"`
FuseMountOptions string `json:"fuseMountOptions,omitempty"`
}
type CsiNFSSpec struct {
@@ -278,3 +282,75 @@ func SaveClusterConfig(clientset kubernetes.Interface, clusterNamespace string,
return nil
}
// updateCSIDriverOptions updates the CSI driver options, including read affinity, kernel mount options
// and fuse mount options, for all entries belonging to the same cluster.
func updateCSIDriverOptions(curr, clusterKey string,
csiDriverOptions *cephv1.CSIDriverSpec) (string, error) {
cc, err := parseCsiClusterConfig(curr)
if err != nil {
return "", errors.Wrap(err, "failed to parse current csi cluster config")
}
for i := range cc {
// If the clusterID belongs to the same cluster, update the entry.
if clusterKey == cc[i].Namespace {
cc[i].ReadAffinity = &csiDriverOptions.ReadAffinity
if cc[i].CephFS == nil {
cc[i].CephFS = &CsiCephFSSpec{
KernelMountOptions: csiDriverOptions.CephFS.KernelMountOptions,
FuseMountOptions: csiDriverOptions.CephFS.FuseMountOptions,
}
} else {
cc[i].CephFS.KernelMountOptions = csiDriverOptions.CephFS.KernelMountOptions
cc[i].CephFS.FuseMountOptions = csiDriverOptions.CephFS.FuseMountOptions
}
}
}
return formatCsiClusterConfig(cc)
}
// SaveCSIDriverOptions, similar to SaveClusterConfig, updates the config map used by ceph-csi
// with CSI driver options such as read affinity, kernel mount options and fuse mount options.
func SaveCSIDriverOptions(clientset kubernetes.Interface, clusterNamespace string, clusterInfo *cephclient.ClusterInfo) error {
// csi is deployed into the same namespace as the operator
csiNamespace := os.Getenv(k8sutil.PodNamespaceEnvVar)
if csiNamespace == "" {
logger.Warningf("cannot save csi config due to missing env var %q", k8sutil.PodNamespaceEnvVar)
return nil
}
logger.Debugf("using %q for csi configmap namespace", csiNamespace)
configMutex.Lock()
defer configMutex.Unlock()
// fetch current ConfigMap contents
configMap, err := clientset.CoreV1().ConfigMaps(csiNamespace).Get(clusterInfo.Context, ConfigName, metav1.GetOptions{})
if err != nil {
return errors.Wrap(err, "failed to fetch current csi config map")
}
// update ConfigMap contents for current cluster
currData := configMap.Data[ConfigKey]
if currData == "" {
currData = "[]"
}
newData, err := updateCSIDriverOptions(currData, clusterNamespace, &clusterInfo.CSIDriverSpec)
if err != nil {
return errors.Wrap(err, "failed to update csi config map data")
}
if currData == newData {
// no change
return nil
}
// update ConfigMap with new contents
configMap.Data[ConfigKey] = newData
if _, err := clientset.CoreV1().ConfigMaps(csiNamespace).Update(clusterInfo.Context, configMap, metav1.UpdateOptions{}); err != nil {
return errors.Wrap(err, "failed to update csi config map with csi driver options")
}
return nil
}
@@ -20,6 +20,7 @@ import (
"strings"
"testing"
cephv1 "github.com/rook/rook/pkg/apis/ceph.rook.io/v1"
cephclient "github.com/rook/rook/pkg/daemon/ceph/client"
"github.com/stretchr/testify/assert"
)
@@ -391,3 +392,148 @@ func verifyEndpointPort(t *testing.T, endpoints []string, expectedPort string) {
assert.True(t, strings.HasSuffix(endpoint, expectedPort))
}
}
func TestUpdateCSIDriverOptions(t *testing.T) {
type args struct {
clusterConfig csiClusterConfig
clusterKey string
csiDriverOptions *cephv1.CSIDriverSpec
}
tests := []struct {
name string
args args
want csiClusterConfig
wantErr bool
}{
{
name: "empty current config",
args: args{
clusterConfig: []CsiClusterConfigEntry{},
clusterKey: "rook-ceph",
csiDriverOptions: &cephv1.CSIDriverSpec{},
},
want: []CsiClusterConfigEntry{},
wantErr: false,
},
{
name: "single matching current config",
args: args{
clusterConfig: []CsiClusterConfigEntry{
{
ClusterID: "rook-ceph",
Namespace: "rook-ceph",
Monitors: []string{"1.1.1.1"},
},
},
clusterKey: "rook-ceph",
csiDriverOptions: &cephv1.CSIDriverSpec{
ReadAffinity: cephv1.ReadAffinitySpec{
Enabled: true,
CrushLocationLabels: []string{"topology.rook.io/rack"},
},
CephFS: cephv1.CSICephFSSpec{
KernelMountOptions: "rw,noatime",
FuseMountOptions: "debug",
},
},
},
want: []CsiClusterConfigEntry{
{
ClusterID: "rook-ceph",
Namespace: "rook-ceph",
Monitors: []string{"1.1.1.1"},
ReadAffinity: &cephv1.ReadAffinitySpec{
Enabled: true,
CrushLocationLabels: []string{"topology.rook.io/rack"},
},
CephFS: &CsiCephFSSpec{
KernelMountOptions: "rw,noatime",
FuseMountOptions: "debug",
},
},
},
wantErr: false,
},
{
name: "multiple matching current config",
args: args{
clusterConfig: []CsiClusterConfigEntry{
{
ClusterID: "rook-ceph",
Namespace: "rook-ceph",
Monitors: []string{"1.1.1.1"},
},
{
ClusterID: "rook-ceph-2",
Namespace: "rook-ceph",
Monitors: []string{"1.1.1.1"},
},
{
ClusterID: "rook-ceph-3",
Namespace: "rook-ceph-1",
Monitors: []string{"1.1.1.1"},
},
},
clusterKey: "rook-ceph",
csiDriverOptions: &cephv1.CSIDriverSpec{
ReadAffinity: cephv1.ReadAffinitySpec{
Enabled: true,
CrushLocationLabels: []string{"topology.rook.io/rack"},
},
CephFS: cephv1.CSICephFSSpec{
KernelMountOptions: "rw,noatime",
FuseMountOptions: "debug",
},
},
},
want: []CsiClusterConfigEntry{
{
ClusterID: "rook-ceph",
Namespace: "rook-ceph",
Monitors: []string{"1.1.1.1"},
ReadAffinity: &cephv1.ReadAffinitySpec{
Enabled: true,
CrushLocationLabels: []string{"topology.rook.io/rack"},
},
CephFS: &CsiCephFSSpec{
KernelMountOptions: "rw,noatime",
FuseMountOptions: "debug",
},
},
{
ClusterID: "rook-ceph-2",
Namespace: "rook-ceph",
Monitors: []string{"1.1.1.1"},
ReadAffinity: &cephv1.ReadAffinitySpec{
Enabled: true,
CrushLocationLabels: []string{"topology.rook.io/rack"},
},
CephFS: &CsiCephFSSpec{
KernelMountOptions: "rw,noatime",
FuseMountOptions: "debug",
},
},
{
ClusterID: "rook-ceph-3",
Namespace: "rook-ceph-1",
Monitors: []string{"1.1.1.1"},
},
},
wantErr: false,
},
}
for _, tt := range tests {
t.Run(tt.name, func(t *testing.T) {
dataString, err := formatCsiClusterConfig(tt.args.clusterConfig)
assert.NoError(t, err)
got, err := updateCSIDriverOptions(dataString, tt.args.clusterKey, tt.args.csiDriverOptions)
if (err != nil) != tt.wantErr {
t.Errorf("updateCSIDriverOptions() error = %v, wantErr %v", err, tt.wantErr)
return
}
expectedString, err := formatCsiClusterConfig(tt.want)
assert.NoError(t, err)
assert.Equal(t, expectedString, got)
})
}
}
+6 -2
View File
@@ -868,8 +868,12 @@ func (r *ReconcileCSI) configureHolder(driver driverDetails, c ClusterDetail, tp
clusterConfigEntry := &CsiClusterConfigEntry{
Monitors: MonEndpoints(c.clusterInfo.Monitors, c.cluster.Spec.RequireMsgr2()),
RBD: &CsiRBDSpec{},
CephFS: &CsiCephFSSpec{},
NFS: &CsiNFSSpec{},
CephFS: &CsiCephFSSpec{
FuseMountOptions: c.clusterInfo.CSIDriverSpec.CephFS.FuseMountOptions,
KernelMountOptions: c.clusterInfo.CSIDriverSpec.CephFS.KernelMountOptions,
},
NFS: &CsiNFSSpec{},
ReadAffinity: &c.clusterInfo.CSIDriverSpec.ReadAffinity,
}
netNamespaceFilePath := generateNetNamespaceFilePath(CSIParam.KubeletDirPath, driver.fullName, c.cluster.Namespace)
if driver.name == RBDDriverShortName {
@@ -269,8 +269,11 @@ func (r *ReconcileCephFilesystemSubVolumeGroup) updateClusterConfig(cephFilesyst
Namespace: r.clusterInfo.Namespace,
Monitors: csi.MonEndpoints(r.clusterInfo.Monitors, cephCluster.Spec.RequireMsgr2()),
CephFS: &csi.CsiCephFSSpec{
SubvolumeGroup: cephFilesystemSubVolumeGroup.Name,
SubvolumeGroup: cephFilesystemSubVolumeGroup.Name,
KernelMountOptions: r.clusterInfo.CSIDriverSpec.CephFS.KernelMountOptions,
FuseMountOptions: r.clusterInfo.CSIDriverSpec.CephFS.FuseMountOptions,
},
ReadAffinity: &r.clusterInfo.CSIDriverSpec.ReadAffinity,
}
// If the cluster has Multus enabled we need to append the network namespace of the driver's
@@ -264,6 +264,11 @@ func (r *ReconcileCephBlockPoolRadosNamespace) updateClusterConfig(cephBlockPool
RadosNamespace: cephBlockPoolRadosNamespace.Name,
},
RadosNamespace: cephBlockPoolRadosNamespace.Name,
CephFS: &csi.CsiCephFSSpec{
KernelMountOptions: r.clusterInfo.CSIDriverSpec.CephFS.KernelMountOptions,
FuseMountOptions: r.clusterInfo.CSIDriverSpec.CephFS.FuseMountOptions,
},
ReadAffinity: &r.clusterInfo.CSIDriverSpec.ReadAffinity,
}
if cephCluster.Spec.Network.IsMultus() {