Merge pull request #2993 from travisn/ceph-volume-logging
Write ceph-volume log entries as they occur
This commit is contained in:
2 files changed
+8
-4
No files matched your search
@@ -50,7 +50,7 @@ func StartOSD(context *clusterd.Context, osdType, osdID, osdUUID string, cephArg
|
||||
|
||||
// activate the osd with ceph-volume
|
||||
storeFlag := "--" + osdType
|
||||
if err := context.Executor.ExecuteCommand(false, "", "ceph-volume", "lvm", "activate", "--no-systemd", storeFlag, osdID, osdUUID); err != nil {
|
||||
if err := context.Executor.ExecuteCommand(false, "", "stdbuf", "-oL", "ceph-volume", "lvm", "activate", "--no-systemd", storeFlag, osdID, osdUUID); err != nil {
|
||||
return fmt.Errorf("failed to activate osd. %+v", err)
|
||||
}
|
||||
|
||||
|
||||
@@ -69,7 +69,10 @@ func (a *OsdAgent) initializeDevices(context *clusterd.Context, devices *DeviceO
|
||||
storeFlag = "--filestore"
|
||||
}
|
||||
|
||||
baseArgs := []string{"lvm", "batch", "--prepare", storeFlag, "--yes"}
|
||||
// Use stdbuf to capture the python output buffer such that we can write to the pod log as the logging happens
|
||||
// instead of using the default buffering that will log everything after ceph-volume exits
|
||||
baseCommand := "stdbuf"
|
||||
baseArgs := []string{"-oL", cephVolumeCmd, "lvm", "batch", "--prepare", storeFlag, "--yes"}
|
||||
if a.storeConfig.EncryptedDevice {
|
||||
baseArgs = append(baseArgs, encryptedFlag)
|
||||
}
|
||||
@@ -105,7 +108,7 @@ func (a *OsdAgent) initializeDevices(context *clusterd.Context, devices *DeviceO
|
||||
sanitizeOSDsPerDevice(device.Config.OSDsPerDevice),
|
||||
}...)
|
||||
|
||||
if err := context.Executor.ExecuteCommand(false, "", cephVolumeCmd, immediateExecuteArgs...); err != nil {
|
||||
if err := context.Executor.ExecuteCommand(false, "", baseCommand, immediateExecuteArgs...); err != nil {
|
||||
return fmt.Errorf("failed ceph-volume. %+v", err)
|
||||
}
|
||||
|
||||
@@ -116,7 +119,8 @@ func (a *OsdAgent) initializeDevices(context *clusterd.Context, devices *DeviceO
|
||||
}
|
||||
|
||||
if configured > 0 {
|
||||
if err := context.Executor.ExecuteCommand(false, "", cephVolumeCmd, batchArgs...); err != nil {
|
||||
// Run "stdbuf -oL ceph-volume" so we can get more frequent updates in the container logs
|
||||
if err := context.Executor.ExecuteCommand(false, "", baseCommand, batchArgs...); err != nil {
|
||||
return fmt.Errorf("failed ceph-volume. %+v", err)
|
||||
}
|
||||
}
|
||||
|
||||
Reference in new issue