docs: separate network providers into sub-doc
Some users are still confused by Ceph networking, especially involving Multus. Continuing to add network provider-specific information -- a pretty advanced concept -- to the already-heavy CephCluster CRD doc is becoming cumbersome. Separate network provider settings into a separate child doc that notes it is an advanced topic. This separation will also help with work to remove the holder pod design, which requires additional Multus prerequisites. See: https://github.com/rook/rook/issues/13055 Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
This commit is contained in:
2 files changed
+194
-147
No files matched your search
@@ -223,154 +223,10 @@ Configure the network that will be enabled for the cluster and services.
|
||||
Changing networking configuration after a Ceph cluster has been deployed is NOT
|
||||
supported and will result in a non-functioning cluster.
|
||||
|
||||
#### Ceph public and cluster networks
|
||||
#### Provider
|
||||
|
||||
Ceph daemons can operate on up to two distinct networks: public, and cluster.
|
||||
|
||||
Ceph daemons always use the public network, which is the Kubernetes pod network by default. The
|
||||
public network is used for client communications with the Ceph cluster (reads/writes).
|
||||
|
||||
If specified, the cluster network is used to isolate internal Ceph replication traffic. This includes
|
||||
additional copies of data replicated between OSDs during client reads/writes. This also includes OSD
|
||||
data recovery (re-replication) when OSDs or nodes go offline. If the cluster network is unspecified,
|
||||
the public network is used for this traffic instead.
|
||||
|
||||
Some Rook network providers allow manually specifying the public and network interfaces that Ceph
|
||||
will use for data traffic. Use `addressRanges` to specify this. For example:
|
||||
|
||||
```yaml
|
||||
network:
|
||||
provider: host
|
||||
addressRanges:
|
||||
public:
|
||||
- "192.168.100.0/24"
|
||||
- "192.168.101.0/24"
|
||||
cluster:
|
||||
- "192.168.200.0/24"
|
||||
```
|
||||
|
||||
This spec translates directly to Ceph's `public_network` and `host_network` configurations.
|
||||
Refer to [Ceph networking documentation](https://docs.ceph.com/docs/master/rados/configuration/network-config-ref/)
|
||||
for more details.
|
||||
|
||||
The default, unspecified network provider cannot make use of these configurations.
|
||||
|
||||
Ceph public and cluster network configurations are allowed to change, but this should be done with
|
||||
great care. When updating underlying networks or Ceph network settings, Rook assumes that the
|
||||
current network configuration used by Ceph daemons will continue to operate as intended. Network
|
||||
changes are not applied to Ceph daemon pods (like OSDs and MDSes) until the pod is restarted. When
|
||||
making network changes, ensure that restarted pods will not lose connectivity to existing pods, and
|
||||
vice versa.
|
||||
|
||||
#### Host Networking
|
||||
|
||||
To use host networking, set `provider: host`.
|
||||
|
||||
To instruct Ceph to operate on specific host interfaces or networks, use `addressRanges` to select
|
||||
the network CIDRs Ceph will bind to on the host.
|
||||
|
||||
If the host networking setting is changed in a cluster where mons are already running, the existing mons will
|
||||
remain running with the same network settings with which they were created. To complete the conversion
|
||||
to or from host networking after you update this setting, you will need to
|
||||
[failover the mons](../../Storage-Configuration/Advanced/ceph-mon-health.md#failing-over-a-monitor)
|
||||
in order to have mons on the desired network configuration.
|
||||
|
||||
#### Multus
|
||||
|
||||
Rook supports using Multus NetworkAttachmentDefinitions for Ceph public and cluster networks.
|
||||
|
||||
Refer to [Multus documentation](https://github.com/k8snetworkplumbingwg/multus-cni/blob/master/docs/how-to-use.md)
|
||||
for details about how to set up and select Multus networks.
|
||||
|
||||
Rook will attempt to auto-discover the network CIDRs for selected public and/or cluster networks.
|
||||
This process is not guaranteed to succeed. Furthermore, this process will get a new network lease
|
||||
for each CephCluster reconcile. Specify `addressRanges` manually if the auto-detection process
|
||||
fails or if the selected network configuration cannot automatically recycle released network leases.
|
||||
|
||||
Only OSD pods will have both public and cluster networks attached (if specified). The rest of the
|
||||
Ceph component pods and CSI pods will only have the public network attached. The Rook operator will
|
||||
not have any networks attached; it proxies Ceph commands via a sidecar container in the mgr pod.
|
||||
|
||||
A NetworkAttachmentDefinition must exist before it can be used by Multus for a Ceph network. A
|
||||
recommended definition will look like the following:
|
||||
|
||||
```yaml
|
||||
apiVersion: "k8s.cni.cncf.io/v1"
|
||||
kind: NetworkAttachmentDefinition
|
||||
metadata:
|
||||
name: ceph-multus-net
|
||||
namespace: rook-ceph
|
||||
spec:
|
||||
config: '{
|
||||
"cniVersion": "0.3.0",
|
||||
"type": "macvlan",
|
||||
"master": "eth0",
|
||||
"mode": "bridge",
|
||||
"ipam": {
|
||||
"type": "whereabouts",
|
||||
"range": "192.168.200.0/24"
|
||||
}
|
||||
}'
|
||||
```
|
||||
|
||||
* Ensure that `master` matches the network interface on hosts that you want to use.
|
||||
It must be the same across all hosts.
|
||||
* CNI type `macvlan` is highly recommended.
|
||||
It has less CPU and memory overhead compared to traditional Linux `bridge` configurations.
|
||||
* IPAM type `whereabouts` is recommended because it ensures each pod gets an IP address unique
|
||||
within the Kubernetes cluster. No DHCP server is required. If a DHCP server is present on the
|
||||
network, ensure the IP range does not overlap with the DHCP server's range.
|
||||
|
||||
NetworkAttachmentDefinitions are selected for the desired Ceph network using `selectors`. Selector
|
||||
values should include the namespace in which the NAD is present. `public` and `cluster` may be
|
||||
selected independently. If `public` is left unspecified, Rook will configure Ceph to use the
|
||||
Kubernetes pod network for Ceph client traffic.
|
||||
|
||||
Consider the example below which selects a hypothetical Kubernetes-wide Multus network in the
|
||||
default namespace for Ceph's public network and selects a Ceph-specific network in the `rook-ceph`
|
||||
namespace for Ceph's cluster network. The commented-out portion shows an example of how address
|
||||
ranges could be manually specified for the networks if needed.
|
||||
|
||||
```yaml
|
||||
network:
|
||||
provider: multus
|
||||
selectors:
|
||||
public: default/kube-multus-net
|
||||
cluster: rook-ceph/ceph-multus-net
|
||||
# addressRanges:
|
||||
# public:
|
||||
# - "192.168.100.0/24"
|
||||
# - "192.168.101.0/24"
|
||||
# cluster:
|
||||
# - "192.168.200.0/24"
|
||||
```
|
||||
|
||||
##### Validating Multus configuration
|
||||
|
||||
We **highly** recommend validating your Multus configuration before you install Rook. A tool exists
|
||||
to facilitate validating the Multus configuration. After installing the Rook operator and before
|
||||
installing any Custom Resources, run the tool from the operator pod.
|
||||
|
||||
The tool's CLI is designed to be as helpful as possible. Get help text for the multus validation
|
||||
tool like so:
|
||||
```console
|
||||
kubectl --namespace rook-ceph exec -it deploy/rook-ceph-operator -- rook multus validation run --help
|
||||
```
|
||||
|
||||
Then, update the args in the [multus-validation](https://github.com/rook/rook/blob/master/deploy/examples/multus-validation.yaml) job template. Minimally, add the NAD names(s) for public and/or cluster as needed and and then, create the job to validate the Multus configuration.
|
||||
|
||||
If the tool fails, it will suggest what things may be preventing Multus networks from working
|
||||
properly, and it will request the logs and outputs that will help debug issues.
|
||||
|
||||
Check the logs of the pod created by the job to know the status of the validation test.
|
||||
|
||||
##### Known limitations with Multus
|
||||
|
||||
Daemons leveraging Kubernetes service IPs (Monitors, Managers, Rados Gateways) are not listening on the NAD specified in the `selectors`.
|
||||
Instead the daemon listens on the default network, however the NAD is attached to the container,
|
||||
allowing the daemon to communicate with the rest of the cluster. There is work in progress to fix
|
||||
this issue in the [multus-service](https://github.com/k8snetworkplumbingwg/multus-service)
|
||||
repository. At the time of writing it's unclear when this will be supported.
|
||||
Selecting a non-default network provider is an advanced topic. Read more in the
|
||||
[Network Providers](./network-providers.md) documentation.
|
||||
|
||||
#### IPFamily
|
||||
|
||||
|
||||
@@ -0,0 +1,191 @@
|
||||
---
|
||||
title: Network Providers
|
||||
---
|
||||
|
||||
Rook deploys CephClusters using Kubernetes' software-defined networks by default. This is simple for
|
||||
users, provides necessary connectivity, and has good node-level security. However, this comes at the
|
||||
expense of additional latency, and the storage network must contend with Kubernetes applications for
|
||||
network bandwidth. It also means that Kubernetes applications coexist on the same network as Ceph
|
||||
daemons and can reach the Ceph cluster easily via network scanning.
|
||||
|
||||
Rook allows selecting alternative network providers to address some of these downsides, sometimes at
|
||||
the expense of others. Selecting alternative network providers is an advanced topic.
|
||||
|
||||
!!! Note
|
||||
This is an advanced networking topic.
|
||||
See also the [CephCluster general networking settings.](./ceph-cluster-crd.md#network-configuration-settings)
|
||||
|
||||
## Ceph Networking Fundamentals
|
||||
|
||||
Ceph daemons can operate on up to two distinct networks: public, and cluster.
|
||||
|
||||
Ceph daemons always use the public network. The public network is used for client communications
|
||||
with the Ceph cluster (reads/writes). Rook configures this as the Kubernetes pod network by default.
|
||||
Ceph-CSI uses this network for PVCs.
|
||||
|
||||
The cluster network is optional and is used to isolate internal Ceph replication traffic. This
|
||||
includes additional copies of data replicated between OSDs during client reads/writes. This also
|
||||
includes OSD data recovery (re-replication) when OSDs or nodes go offline. If the cluster network is
|
||||
unspecified, the public network is used for this traffic instead.
|
||||
|
||||
Refer to [Ceph networking documentation](https://docs.ceph.com/docs/master/rados/configuration/network-config-ref/)
|
||||
for deeper explanations of any topics.
|
||||
|
||||
## Specifying Ceph Network Selections
|
||||
`network.addressRanges`
|
||||
|
||||
This configuration is always optional but is important to understand.
|
||||
|
||||
Some Rook network providers allow specifying the public and network interfaces that Ceph will use
|
||||
for data traffic. Use `addressRanges` to specify this. For example:
|
||||
|
||||
```yaml
|
||||
network:
|
||||
provider: host
|
||||
addressRanges:
|
||||
public:
|
||||
- "192.168.100.0/24"
|
||||
- "192.168.101.0/24"
|
||||
cluster:
|
||||
- "192.168.200.0/24"
|
||||
```
|
||||
|
||||
This `public` and `cluster` translate directly to Ceph's `public_network` and `host_network`
|
||||
configurations.
|
||||
|
||||
The default network provider cannot make use of these configurations.
|
||||
|
||||
Ceph public and cluster network configurations are allowed to change, but this should be done with
|
||||
great care. When updating underlying networks or Ceph network settings, Rook assumes that the
|
||||
current network configuration used by Ceph daemons will continue to operate as intended. Network
|
||||
changes are not applied to Ceph daemon pods (like OSDs and MDSes) until the pod is restarted. When
|
||||
making network changes, ensure that restarted pods will not lose connectivity to existing pods, and
|
||||
vice versa.
|
||||
|
||||
## Host Networking
|
||||
`network.provider: host`
|
||||
|
||||
Host networking allows the Ceph cluster to use network interfaces on Kubernetes hosts for
|
||||
communication. This eliminates latency from the software-defined pod network, but it provides no
|
||||
host-level security isolation.
|
||||
|
||||
Ceph daemons will use any network available on the host for communication. To restrict Ceph to using
|
||||
only a specific specific host interfaces or networks, use `addressRanges` to select the network
|
||||
CIDRs Ceph will bind to on the host.
|
||||
|
||||
If the host networking setting is changed in a cluster where mons are already running, the existing mons will
|
||||
remain running with the same network settings with which they were created. To complete the conversion
|
||||
to or from host networking after you update this setting, you will need to
|
||||
[failover the mons](../../Storage-Configuration/Advanced/ceph-mon-health.md#failing-over-a-monitor)
|
||||
in order to have mons on the desired network configuration.
|
||||
|
||||
## Multus
|
||||
`network.provider: multus`
|
||||
|
||||
Rook supports using Multus NetworkAttachmentDefinitions for Ceph public and cluster networks.
|
||||
|
||||
This allows Rook to attach any CNI to Ceph as a public and/or cluster network. This provides strong
|
||||
isolation between Kubernetes applications and Ceph cluster daemons.
|
||||
|
||||
While any CNI may be used, the intent is to allow use of CNIs which allow Ceph to be connected to
|
||||
specific host interfaces. This improves latency and bandwidth while preserving host-level network
|
||||
isolation.
|
||||
|
||||
### Multus Configuration
|
||||
|
||||
Refer to [Multus documentation](https://github.com/k8snetworkplumbingwg/multus-cni/blob/master/docs/how-to-use.md)
|
||||
for details about how to set up and select Multus networks.
|
||||
|
||||
Rook will attempt to auto-discover the network CIDRs for selected public and/or cluster networks.
|
||||
This process is not guaranteed to succeed. Furthermore, this process will get a new network lease
|
||||
for each CephCluster reconcile. Specify `addressRanges` manually if the auto-detection process
|
||||
fails or if the selected network configuration cannot automatically recycle released network leases.
|
||||
|
||||
Only OSD pods will have both public and cluster networks attached (if specified). The rest of the
|
||||
Ceph component pods and CSI pods will only have the public network attached. The Rook operator will
|
||||
not have any networks attached; it proxies Ceph commands via a sidecar container in the mgr pod.
|
||||
|
||||
A NetworkAttachmentDefinition must exist before it can be used by Multus for a Ceph network. A
|
||||
recommended definition will look like the following:
|
||||
|
||||
```yaml
|
||||
apiVersion: "k8s.cni.cncf.io/v1"
|
||||
kind: NetworkAttachmentDefinition
|
||||
metadata:
|
||||
name: ceph-multus-net
|
||||
namespace: rook-ceph
|
||||
spec:
|
||||
config: '{
|
||||
"cniVersion": "0.3.0",
|
||||
"type": "macvlan",
|
||||
"master": "eth0",
|
||||
"mode": "bridge",
|
||||
"ipam": {
|
||||
"type": "whereabouts",
|
||||
"range": "192.168.200.0/24"
|
||||
}
|
||||
}'
|
||||
```
|
||||
|
||||
* Ensure that `master` matches the network interface on hosts that you want to use.
|
||||
It must be the same across all hosts.
|
||||
* CNI type `macvlan` is highly recommended.
|
||||
It has less CPU and memory overhead compared to traditional Linux `bridge` configurations.
|
||||
* IPAM type `whereabouts` is recommended because it ensures each pod gets an IP address unique
|
||||
within the Kubernetes cluster. No DHCP server is required. If a DHCP server is present on the
|
||||
network, ensure the IP range does not overlap with the DHCP server's range.
|
||||
|
||||
NetworkAttachmentDefinitions are selected for the desired Ceph network using `selectors`. Selector
|
||||
values should include the namespace in which the NAD is present. `public` and `cluster` may be
|
||||
selected independently. If `public` is left unspecified, Rook will configure Ceph to use the
|
||||
Kubernetes pod network for Ceph client traffic.
|
||||
|
||||
Consider the example below which selects a hypothetical Kubernetes-wide Multus network in the
|
||||
default namespace for Ceph's public network and selects a Ceph-specific network in the `rook-ceph`
|
||||
namespace for Ceph's cluster network. The commented-out portion shows an example of how address
|
||||
ranges could be manually specified for the networks if needed.
|
||||
|
||||
```yaml
|
||||
network:
|
||||
provider: multus
|
||||
selectors:
|
||||
public: default/kube-multus-net
|
||||
cluster: rook-ceph/ceph-multus-net
|
||||
# addressRanges:
|
||||
# public:
|
||||
# - "192.168.100.0/24"
|
||||
# - "192.168.101.0/24"
|
||||
# cluster:
|
||||
# - "192.168.200.0/24"
|
||||
```
|
||||
|
||||
### Validating Multus configuration
|
||||
|
||||
We **highly** recommend validating your Multus configuration before you install Rook. A tool exists
|
||||
to facilitate validating the Multus configuration. After installing the Rook operator and before
|
||||
installing any Custom Resources, run the tool from the operator pod.
|
||||
|
||||
The tool's CLI is designed to be as helpful as possible. Get help text for the multus validation
|
||||
tool like so:
|
||||
```console
|
||||
kubectl --namespace rook-ceph exec -it deploy/rook-ceph-operator -- rook multus validation run --help
|
||||
```
|
||||
|
||||
Then, update the args in the
|
||||
[multus-validation](https://github.com/rook/rook/blob/master/deploy/examples/multus-validation.yaml)
|
||||
job template. Minimally, add the NAD names(s) for public and/or cluster as needed and and then,
|
||||
create the job to validate the Multus configuration.
|
||||
|
||||
If the tool fails, it will suggest what things may be preventing Multus networks from working
|
||||
properly, and it will request the logs and outputs that will help debug issues.
|
||||
|
||||
Check the logs of the pod created by the job to know the status of the validation test.
|
||||
|
||||
### Known limitations with Multus
|
||||
|
||||
Daemons leveraging Kubernetes service IPs (Monitors, Managers, Rados Gateways) are not listening on
|
||||
the NAD specified in the `selectors`. Instead the daemon listens on the default network, however the
|
||||
NAD is attached to the container, allowing the daemon to communicate with the rest of the cluster.
|
||||
There is work in progress to fix this issue in the
|
||||
[multus-service](https://github.com/k8snetworkplumbingwg/multus-service) repository. At the time of
|
||||
writing it's unclear when this will be supported.
|
||||
Reference in new issue