doc: cleanup of the OSD migration design document

Signed-off-by: Anthony D'Atri <anthonyeleven@users.noreply.github.com>
This commit is contained in:
Anthony D'Atri committed 2023-08-30 00:37:58 -04:00
1 parent 163f0d3ccc
commit ebb8d4f043
1 file changed
+79 -42
+79 -42
View File
@@ -2,29 +2,45 @@
## Summary
- Configure OSD backend store via `cephCluster` CR so that new OSDs can use it.
- Existing OSDs should be able to migrate to use a new backend store configured via `cephCluster` CR. The migration process should include destroying the existing OSDs one by one, wiping the disk and then creating a new OSD on that disk.
- Configure the default OSD backend via the `cephCluster` CR so that new OSDs
are built with it.
- Existing OSDs should be able to migrate to use a new backend store configured
via `cephCluster` CR. The migration process should include destroying the
existing OSDs one by one, wiping the drive, then recreating a new OSD on
that drive with the same ID.
## Motivation:
- Ceph uses BlueStore as a special-purpose storage back end designed specifically for managing data on disk for Ceph OSD workloads. Ceph team is working on improving this backend storage that will help in significantly improving the performance, especially in disaster recovery scenarios. This new OSD backend is known as `bluestore-rdr`. In the future, other backends will also need to be supported, such as `seastore`.
- To support any new and improved storage backend, the existing OSD needs to be destroyed, disks should be wiped out and new OSD should be created using the latest storage backend.
- Ceph uses BlueStore as a special-purpose storage backend designed specifically
for Ceph OSD workloads. The upstream Ceph team is working on improving
BlueStore in ways that will significantly improve performance, especially
in disaster recovery scenarios. This new OSD backend is known as
`bluestore-rdr`. In the future, other backends will also need to be supported,
such as `seastore` from the Crimson effort.
- To employ a new torage backend, the existing OSD needs to be destroyed, drives
wiped, and new OSD created using the specified storage backend.
## Goals
- Newly provisioned clusters should be able to use the specific storage backend while creating OSDs.
- Existing clusters should be able to migrate the OSDs to use a specific storage backend, without downtime and without risking data loss.
- Newly provisioned clusters should be able to use the specific storage backend
when creating OSDs.
- Existing clusters should be able to migrate existing OSDs to a specific
backend, without downtime and without risking data loss. Note that this
necessarily entails redeploying and backfilling each OSD in turn.
## Non-Goals/Deferred Features:
Migration of OSDs with following configurations is deferred for now and will be taken up in future:
- OSDs on mixed media setup where metadata (RocksDB+WAL) is placed on higher throughput storage media and application data on lower throughput media.
- Setups with multiple OSDs per disk.
Migration of OSDs with following configurations is deferred for now and will
considered in the future:
- Hybrid OSDs where metadata (RocksDB+WAL) is placed on faster storage media
and application data on slower media.
- Setups with multiple OSDs per drive, though with recent Ceph releases the
motivation for deploying this way is mostly obviated.
## Proposal
### API Changes
- Add `spec.storage.store` in the ceph cluster yaml.
- Add `spec.storage.store` in the Ceph cluster YAML.
```yaml
storage:
@@ -33,11 +49,16 @@ Migration of OSDs with following configurations is deferred for now and will be
updateStore: yes-really-update-store
```
- `type`: The type of backend store to be used for OSDs. For example, bluestore, bluestore-rdr, etc. The default store type will be `bluestore`
- `updateStore`: Allows the user to migrate the existing OSDs to use any new storage backend. This field can only take the value as `yes-really-update-store`. If the user wants to change the `store.type` field for an existing cluster, then they will also need to update `spec.storage.store.updateStore` with `yes-really-update-store`
- `type`: The backend to be used for OSDs: `bluestore`, `bluestore-rdr`,
etc. The default type will be `bluestore`
- `updateStore`: Allows the operator to migrate existing OSDs to a different
backend. This field can only take the value `yes-really-update-store`. If
the user wants to change the `store.type` field for an existing cluster,
they will also need to update `spec.storage.store.updateStore` with `yes-really-update-store`.
- Add `status.storage.osd` to the ceph cluster status. This will help convey the overall status of the OSD migration
- Add `status.storage.osd` to the Ceph cluster status. This will help convey the progress
of OSD migration
``` yaml
status:
@@ -48,21 +69,31 @@ Migration of OSDs with following configurations is deferred for now and will be
bluestore-rdr: 5
```
- `storeType.bluestore`: Total number of bluestore OSDs running
- `storeType.bluestore-rdr`: Total number of bluestore-rdr OSDs running
- Cluster `phase` should be set to progressing while OSDs are migrating
- `storeType.bluestore`: Total number of BlueStore OSDs running
- `storeType.bluestore-rdr`: Total number of BlueStore-rdr OSDs running
- The cluster's `phase` should be set to `progressing` while OSDs are migrating
The migration process will involve destroying the existing OSDs one by one, wiping the disks, creating a new OSD and waiting for the PGs to be active+clean before migrating the next OSD. Since this operation involves possible downtime, users should be really sure before proceeding with this action.
The migration process will involve destroying existing OSDs one by one, wiping
the drives, deploying a new OSD with the same ID, then waiting for all PGs
to be `active+clean` before migrating the next OSD. Since this operation
involves possible impact or downtime, users should be exercise caution
before proceeding with this action.
**NOTE**: Once the OSDs are migrated to a new backend store, say, `bluestore-rdr`, they won't be allowed to be migrated back to the legacy store (bluestore).
**NOTE**: Once the OSDs are migrated to a new backend, say `bluestore-rdr`, they
won't be allowed to be migrated back to the legacy store (BlueStore).
- Add a new label `osd-store:<osd store type>` to all the OSD pods.
- This label will help to identify the current backend store being used for the OSD and enable the operator to decide if the OSD should be migrated in case the user changes the backend store type in the spec (`spec.Storage.store.type`).
- Add a new label `osd-store:<osd store type>` to all OSD pods.
- This label will help to identify the current backend being used for the OSD
and enable the operator to determine if the OSD should be migrated if the
the admin changes the backend type in the spec (`spec.Storage.store.type`).
### New OSDs
- Add the OSD store provided by the user in `spec.storage.store.type` as an environment variable in the OSD prepare job. If no OSD store is provided in the spec, then set the environment variable to `bluestore`.
- The prepare pod will use this environment variable while preparing OSDs using `ceph-volume` command.
- Set the OSD backend provided by the user in `spec.storage.store.type` as an
environment variable in the OSD prepare job. If no OSD store is provided in
the spec, then set the environment variable to `bluestore`.
- The prepare pod will use this environment variable when preparing OSDs
with the `ceph-volume` command.
#### OSD Prepare
@@ -78,15 +109,20 @@ The migration process will involve destroying the existing OSDs one by one, wipi
ceph-volume lvm prepare <OSD_STORE_ENV_VARIABLE> --data /dev/vda
```
#### OSD Activate
#### OSD Activation
ceph-volume `activate` command doesn't require OSD store flag to be passed as an argument. It auto detects the backend store that was used during the OSD `prepare`
The ceph-volume `activate` command doesn't require the OSD backend to be passed
as an argument. It auto-detects the backend that was used during when the OSD
was prepared.
### Existing OSDs
- After upgrading an existing rook ceph cluster to a Ceph version that supports `bluestore-rdr`, users can upgrade the `bluestore` based OSDs to use `bluestore-rdr`
- Backend store of the OSDs can not be overridden, so this update will require the OSDs to be replaced one by one.
- In order to migrate OSDs to use `bluestore-rdr`, users need to patch the ceph cluster spec like below:
- After upgrading an existing Rook Ceph cluster to a Ceph release that supports
`bluestore-rdr`, admins can migrate `bluestore` OSDs to `bluestore-rdr`.
- The backend of OSDs can not be overridden, so this update will require
the OSDs to be replaced one by one.
- In order to migrate OSDs to use `bluestore-rdr`, admins must patch the
Ceph cluster spec as below:
```yaml
storage:
@@ -96,23 +132,23 @@ storage:
```
#### Replace OSD
Operator reconciler will replace one OSD at a time.
A config map will be used to store the OSD being replaced currently.
The operator's reconciler will replace one OSD at a time.
A configmap will be used to store the OSD ID currently being migrated.
OSD replacement steps:
1. List out all OSDs where `osd-store:<osd store type>` does not match with `spec.storage.store.type`.
2. If the PG status is not `active+clean`, don't replace any OSD.
3. If the PG status is `active+clean` but a previous OSD replacement is not completed, then don't replace any new OSD.
4. If the PG status is `active+clean` and no replacement is in progress, then select an OSD to be replaced from the list.
1. List all OSDs where `osd-store:<osd store type>` does not match `spec.storage.store.type`.
2. If all PGs are not `active+clean`, do not proceed.
3. If all PGs are `active+clean` but a previous OSD replacement is not completed, do not proceed.
4. If all PGs are `active+clean` and no replacement is in progress, then select an OSD to be migrated.
5. Delete the OSD deployment.
6. Create an OSD prepare job with an environment variable of OSD ID to be replaced.
7. OSD prepare pod will destroy the OSD and prepare it again using the same OSD ID. Refer [Destroy OSD](#destroy-osd) for details.
8. Once the destroyed OSD pod is added back, delete the configmap.
9. If there is any error during the OSD migration, then preserve the OSD being replaced in the configmap for next reconcile.
10. Reconcile the operator and perform as same steps until all the OSDs have migrated to the new backend store.
6. Create an OSD prepare job with an environment variable indictating the OSD ID to be replaced.
7. The OSD prepare pod will destroy the OSD and prepare it again using the same OSD ID. Refer [Destroy OSD](#destroy-osd) for details.
8. Once the destroyed OSD pod is recreated, delete the configmap.
9. If there is any error during the OSD migration, then preserve the OSD ID being replaced in the configmap for next reconcile.
10. Reconcile the operator and perform as same steps until all the OSDs have migrated to the new backend.
#### Destroy OSD
OSD prepare pod job will destroy an OSD using following steps.
The OSD prepare pod job will destroy an OSD using following steps:
- Check for OSD ID environment variable of the OSD to be destroyed.
- Use `ceph volume list` to fetch the OSD path.
- Destroy the OSD using following command:
@@ -121,7 +157,7 @@ OSD prepare pod job will destroy an OSD using following steps.
ceph osd destroy <OSD_ID> --yes-i-really-mean-it
```
- Wipe the OSD disk. This removes all the data on the device.
- Wipe the OSD drive. This removes all the data on the device.
- Prepare the OSD with the new store type by using the same OSD ID. This is done by passing the OSD ID as `--osd-id` flag to `ceph-volume` command.
```
@@ -130,8 +166,9 @@ OSD prepare pod job will destroy an OSD using following steps.
## Planning
These changes require a significant developemnt effort to migrate existing OSDs to use new backend store. So it will be divided into following stages:
These changes require ignificant developemnt effort to migrate existing OSDs to use a new backend.
They will be divided into following phases:
* New OSDs (greenfield).
* Migrating existing OSDs on PVC without metadata devices.
* Migrating existing OSDs on PVC with metadata devices.
* Existing node-based OSDs (multiple OSDs are created at once using ceph volume batch which adds to additional complications).
* Existing node-based OSDs (multiple OSDs are created at once via `ceph-volume batch` which adds additional complications).