The CreateOrLoadClusterInfo (and therefore LoadClusterInfo) methods were
not loading the ClusterInfo.OwnerInfo. This should help future CRD
controllers get the full ClusterInfo struct without having missing
information. Current controllers that need ClusterInfo fill the field
themselves.
During testing, I observed one corner case where an upgraded cluster was
missing the `rook-ceph-csi-config` configmap. The cluster had a
CephFilesystemSubVolumeGroup resource created, and the reconcile for
that resource was attempting to create the missing CSI configmap and
failing with a nil pointer exception due to the missing OwnerInfo field
in ClusterInfo. This cluster condition hasn't been reproduced in healthy
environments, and it is unknown how the CSI configmap came to be
missing. However, the case did expose the missing loaded info as a
potential for causing nil pointer exceptions during corner cases when
code is otherwise correct.
Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
The following printcolumns were added
CephBlockPoolRadosNamespace: Phase,
BlockPoolName, Age
CephFilesystemSubVolumeGroup: Phase,
FilesystemName, PinningConfig, Age
Also improved the error messages in
SubVolumeGroupClient
Signed-off-by: NymanRobin <nyman.robin@gmail.com>
The mds standby test was timing out after six seconds on
three different attempts, causing a single unit test to
take almost 20 seconds. Now we reduce the wait time to
a total of three seconds.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
For check if cluster PGs are healthy before osd updates
Which helps gainning more confidence in the osd upgrades
Signed-off-by: mmaoyu <wupiaoyu61@gmail.com>
cephfs subvolumegroup supports creating svg
with quota and the datapool, This PR adds the
support for the same.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Cleanup the resources created by subvolumegroup
when its deleted. Following resources will be cleaned up:
- OMAP value
- OMAP keys
- Clones
- Snapshots
- Subvolumes
Signed-off-by: sp98 <sapillai@redhat.com>
Most bullets and numbering in the network providers doc (sub-doc of
CephCluster CR) wasn't rendering properly on the web. Fix by making sure
there is a blank line before each numbered/bulleted section. And make
sure nested numberings are indented 4 spaces.
Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
this commits updates the go version to 1.22.2 in govulncheck ci and
also updates golang.org/x/net to v0.23.0 to fix the ci
Signed-off-by: subhamkrai <srai@redhat.com>
The network providers doc, including the holder pod migration sections,
were developed with the understanding that CSI could be placed into pod
networking mode if desired by users. In reality, this hasn't been
supported due to bugs.
This allows streamlining the holder pod migration sections to no longer
need to document for users what to do if they use CSI in pod network
mode.
Rook will continue to have the `CSI_ENABLE_HOST_NETWORK` config
available as an undocumented value. This can allow users who desperately
cannot use host networking to still use pod networking, though this will
mean any CSI node plugin updates could stall mounts for running apps.
Thus we do not support it.
Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
The csi images in the operator helm chart previously were a single
image name including the repository and tag in a single string.
Now the repository and tag values are separated to allow for
greater customization of the repository from the version tags.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
make the kubectl output for crds more verbose.
Following changes was done for each crd:
CephBlockPool:
Added print columns:
- Type
- FailureDomain
- Replication
- EC-CodingChunks
- EC-DataChunks
- Age
Extended info field of status to include:
type and failureDomain
CephObjectStore:
Added print columns:
- Endpoint
- SecureEndpoint
- Age
Added Age to print columns of following crds:
CephObjectStoreUser, CephObjectZoneGroup,
CephObjectZone, CephBucketTopic, CephClient,
CephRBDMirror, CephFilesystemMirror,
CephFilesystemSubVolumeGroup
Signed-off-by: NymanRobin <nyman.robin@gmail.com>
Pool name either come from CephBlockPool name or
form the CephBlockPool Spec. Use the correct name
when trying to disable mirroring.
Signed-off-by: sp98 <sapillai@redhat.com>
If device set names are duplicated, the OSDs will be very confused
when multiple OSDs attempt to be configured with the same
device set names. Updating the device set names does not help
get out of the error situation since the OSDs will also be
confused about which device set they belong to. The reconcile
must fail completely if the device set names are duplicated
to avoid this error scenario.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>