Update the multus canary test to reflect modern knowledge about how it
should be configured.
No longer test for the network device in OSD pods. Pods will utterly
fail to start if Multus is unable to attach interfaces.
Instead, look to the OSD map to test the connections more wholistically.
OSDs must have map IPs that include both public and cluster network.
This implicitly tests that the interfaces exist in the Pod, and it
additionally verifies other details, like Ceph `*_network` configs are
set propertly.
Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
The prometheus helm chart (kube-prometheus-stack) allows you to restrict
which namespaces prometheus will check for ServiceMonitor objects,
because of this is is typical to be able to configure the namespace of
your ServiceMonitors in helm charts, which is the functionality I have
added here.
Signed-off-by: Mike Hobbs <biz812g@gmail.com>
COSI is not yet ready for declaring stable while
the K8s feature is still in alpha state, despite
how stable Rook's implementation may be.
Signed-off-by: travisn <tnielsen@redhat.com>
Previously ceph-exporter would only bind to IPv4 interfaces. Now if the
CephCluster is configured with `dualStack: true` and/or `ipFamily: IPv6`
an additional flag (`--addrs ::`) will be added to the ceph-exporter
container to make it listen both IPv6 and IPv4 interfaces.
Signed-off-by: Matthew Penner <me@matthewp.io>
For an OBC's name we cannot simply use the OBC's namespace and name,
because they can be reused, while the preceding bucket might be
retained by reclaimPolicy. (Commit 2733375ca4 also didn't solve
this issue, as it is an intra-cluster issue.) Therefore we instead
use the OBC's UID which should be unique within the cluster and
across clusters.
Signed-off-by: Sebastian Hasler <sebastian.hasler@stuvus.uni-stuttgart.de>
The skip-ci label can only be added to the PRs by members of the org,
and also the label is not necessary for changes that are only
to the documentation folder.
Signed-off-by: travisn <tnielsen@redhat.com>
Change how Rook detects network CIDRs for Multus networks. The IPAM
configuration is only defined as an arbitrary string JSON blob with a
"type" field and nothing more. Rook's detection of CIDRs for whereabouts
had already grown out of date since the initial implementation.
Additionally, Rook did not support DHCP IPAM, which is a reasonable
choice for users. And more, Rook did not support CNI plugin chaining,
which further complicates NADs. Based on the CNI spec, network chaning
can result in any changes to network CIDRs from the first-given plugin.
All these problems make it more and more difficult for Rook to support
Multus by inspecting the NAD itself to predict network CIDRs. Instead,
it is better for Rook to treat the CNI process as a black box. To
preserve legacy functionality of auto-detecting networks and to make
that as robust as possible, change to a canary-style architecture like
that used for Ceph mons, from which Rook will detect the network CIDRs
if possible.
Also allow users to specify overrides for CIDR ranges. This allows Rook
to still support esoteric and unexpected NAD or network configurations
where a CIDR range is not detectable or where the range detected would
be incomplete. Because it may be impossible for Rook to understand the
network CIDRs wholistically while residing only on a portion of the
network, this feature should have been present from Multus's inception.
Improving CIDR auto-detection and allowing users to specify overrides
for auto-detected CIDRs rounds out Rook's Multus support for CephCluster
(core/RADOS) installations. No further architectural changes should be
needed for CephClusters as regards application of public/cluster network
CIDRs for Multus networks.
Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
Correctly set discoveryInterval default value by passing defaultDiscoverInterval to k8sutil.GetValue
Allow to set ROOK_DISCOVER_DEVICES_INTERVAL env var through discoveryDaemonInterval helm value
Signed-off-by: Louis Bailleul <louis.bailleul@pgs.com>
In the past we had few cases where the new crd
was missed adding in metadata-common.yaml file.
So, now we'll check if crds.yaml and metadata-common.yaml
crd name are matching.
Signed-off-by: subhamkrai <srai@redhat.com>
This allows the rook mgr module to check if the discovery daemon is enabled. The udev blacklist setting was also moved just to keep similar settings in the same place.
Signed-off-by: Stephen Muth <smuth4@gmail.com>
This simplifies the docs-check workflow definition by extracting functionality
directly coded into the workflow file into new make targets 'check-docs'
and 'check-helm-docs' and replacing the code in the workflow file by the simple invocation of
new make targets. As a side effect, it makes it easily possible for a
developer to check locally if they forgot to commit any autogenerated
docs.
Signed-off-by: Michael Adam <obnox@samba.org>
ceph-exporter's ServiceMonitor and Service CRD contain different port
name, which results in no metrics being collected by prometheus.
this commit makes GetCephMonitor configurable, which we use to set
consistent port names in ServiceMonitor and Service for ceph-exporter.
Signed-off-by: Divyansh Kamboj <dkamboj@redhat.com>
We need to restart all the ceph daemons whenever
cephCluster network settings are modified like
requiremsgr2, encryption and compression. This
required for Ceph to consider the new settings
it require new ceph daemons all over.
Signed-off-by: subhamkrai <srai@redhat.com>
when deploying csi, we'll check if csi-addons crds
are deployed we'll enable csi-addons sidecar by default.
Signed-off-by: subhamkrai <srai@redhat.com>