`xfs`. However further testing shows that, ext4 should be
the default or preferred fs for RBD devices.
This patch bring that change
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
When the flex driver is disabled, the check for
volume attachments will fail and the finalizer
is never removed. To avoid this, just log the
failure to list volumes and remove the
finalizer anyway.
Resolves#3912
Signed-off-by: Kristoffer Grönlund <kgronlund@suse.com>
When displaying the CRDs OLM looks into the alm-examples field in the
CSV file, the NFS CRD example was missing so let's add it.
Signed-off-by: Sébastien Han <seb@redhat.com>
RHEL8 introduces some lvm changes. For OSDs on PVs to work
we need to set allow_changes_with_duplicate_pvs = 1.
This is required since we're copying the block image
under another location.
Signed-off-by: travisn <tnielsen@redhat.com>
currently CSI templates have hardcoded kubelet
path which will be used for mounting PVC,this
will not work if kubelet is configured to use
different path, with this PR kubelet path
can be configured for CSI.
Fixes: #3921
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
When running osds on pvc, the lvm is still holding the device when the cluster is deleted. As a result the PVs go into `failed` state
when the cluster is deleted. On deactivating the device, the 'failed' pvs get deleted as well. Solution involves:
- Running `lvchange -an <vg group name>` to deactivate the device.
- This command runs after 'osd prepare' completes.
- This command also runs after the 'osd daemon pod' is deleted or if the ceph-osd process terminates for some reasons.
Signed-off-by: Santosh Pillai <sapillai@redhat.com>
set containerized flag as false
This is not required as we are setting
containerized=false and we have deprecated
this flag in ceph-csi.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
This change is necessary drain canary pod needs to be schedulable on
the same nodes as the OSDs. Since it affects multiple OSDs, we need to
gather tolerations from multiple OSDs.
Signed-off-by: Rohan CJ <rohantmp@gmail.com>
Also:
* `cluster.yaml`: spec.mgr.modules is not explicily nullable
* Removed `required: mon` in `ceph_manifests.go`
Signed-off-by: Sebastian Wagner <sebastian.wagner@suse.com>
The node selector for running OSDs on PVCs was using the node name
rather than the node's hostname. In clusters where the node name
is different from the hostname this would cause the osd daemons
to be in pending state indefinitely. Now the node selector will
use the hostname as expected.
Signed-off-by: travisn <tnielsen@redhat.com>
On rare occasion, the ceph checks might not be 100% correct and the user
might decide to force an upgrade anyway.
Correctly, if we are in an upgrade, we perform `ok-to-stop` check for
each daemon, if one of them fails, we retry and eventually fail.
They are corner-cases where users would like to force the upgrade anyway.
Enhance the new CR property: "skipUpgradeChecks: true".
Closes: https://github.com/rook/rook/issues/3872
Signed-off-by: Sébastien Han <seb@redhat.com>
updated required rules for upgrading CSI from
v1.0 to v1.1 and also updated the document with
required steps
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>