When CPU requests and limits are assigned to a pod,
the pod will be guaranteed the requests, up to the limits.
Even if there are spare CPU cycles, the pod cannot use
them. Thus, pods can be unnecessarily denied compute
when they need to burst if the limits are set.
Therefore, it is not recommended to set CPU limits
since the CPU requests are already guaranteeing that
no pod will be starved at least for its requests.
Signed-off-by: travisn <tnielsen@redhat.com>
Currently, when rook provisions OSDs(in the OSD prepare job), rook effectively run a
c-v command such as the following.
```console
ceph-volume lvm batch --prepare <deviceA> <deviceB> <deviceC> --db-devices <metadataDevice>
```
but c-v lvm batch only supports disk and lvm, instead of disk partitions.
We can resort to `ceph-volume lvm prepare` to implement it.
Signed-off-by: Liang Zheng <zhengliang0901@gmail.com>
If the import script is run on a system that has many kubernetes configs
in the kubeconfig file, it is useful to be able to specify the context
to use.
Signed-off-by: Raghavendra Talur <raghavendra.talur@gmail.com>
The pg_autoscaler mgr module is no longer possible to disable.
Ceph requires the module to always be enabled. Now the
autoscaling configuration is done with a per-pool setting.
Now the rook module is shown as an example to enable.
Signed-off-by: travisn <tnielsen@redhat.com>
Since v18.2.1 is the default recommendation for the ceph version,
update all the docs and examples to that version.
Signed-off-by: travisn <tnielsen@redhat.com>
Add the missing explanation of pgHealthCheckTimeout and pgHealthyRegex
in the CephCluster' CRD doc. In addition, remove a verbose sentence
from the explanation of `osdMaintenanceTimeout`.
Signed-off-by: Satoru Takeuchi <satoru.takeuchi@gmail.com>
This implements the "Ceph Config via Ceph Cluster CRD" design document
as a `cephConfig:` structure on the CRD.
This also fixes the `yq` commands used to manipulate the
`cluster-test.yaml` that caused CI issues for this PR and potentially
unknowingly others.
Signed-off-by: Alexander Trost <galexrt@googlemail.com>
This commits removes controller-runtime dependencies
from the apis dir and to achieve that we are removing
webhook.
Signed-off-by: subhamkrai <srai@redhat.com>
Originally we create it using this cmd
ceph fs subvolume create <vol_name> <subvol_name>
So we can have 2 variables filesystem and subvolume name,
Currently the CR doesn't allow us to make subvolume-name
as constant as needed to "csi" because of k8s limitations
Signed-off-by: parth-gr <paarora@redhat.com>
This commit adds new CSIDriverOptions section in
cephCluster CR. This section contains settings
for read affinity and kernel+fuse Mount options
These settings will be injected directly into
rook-ceph-csi-config cm to be applicable per
ceph cluster.
Signed-off-by: Rakshith R <rar@redhat.com>
change the json output of storageclass to also inclusde rados namespace,
and also added the changes in the csi secret
Signed-off-by: parth-gr <paarora@redhat.com>
This patch adds `pgHealthyRegex` field to DisruptionManagementSpec.
`pgHealthyRegex` is a regular expression that is used to determine which
PG states should be considered healthy. The default value of
`pgHealthyRegex` is:
^(active\+clean|active\+clean\+scrubbing|active\+clean\+scrubbing\+deep)$
which is effectively the same as before.
Signed-off-by: Ryotaro Banno <ryotaro.banno@gmail.com>
Allow end-user to have full control on NFS-Ganesha liveness probe:
- Disabled
- Enabled, using user-provided definition
- Enabled, using Rook's default liveness probe for Ganesha.
Signed-off-by: Shachar Sharon <ssharon@redhat.com>
It's convenient to visualize the supported OSD configurations.
In addition, remove the reference to the common issue section
about OSD on LV-backed PVC because this issue doesn't happen anymore
for new OSDs.
Closes: https://github.com/rook/rook/issues/10859
Signed-off-by: Satoru Takeuchi <satoru.takeuchi@gmail.com>
when creating networkFence CR, it requires IP's to block
which we get from running `rbd status ...` command. But,
the client.healthchecker user didn't had the right caps
to run hence it was giving error. Now, adding the required
caps `profile rbd-read-only` to osd so that rbd command can
be executed.
Signed-off-by: subhamkrai <srai@redhat.com>
Using the new configuration parameters prometheusEndpoint and
prometheusEndpointSSLVerify users can configure dashboard to
point to their prometheus instance.
closes: #12876
Signed-off-by: Redouane Kachach <rkachach@redhat.com>
When OSDs flap, ceph stops the OSD daemon if its marked down greater than
5 times in 600 seconds. But OSD pod restarts and marks the OSD `up` again.
This causes the PGs mapped to these OSDs to peer. While the PGs are peering,
IO to these PGs are blocked.
So we need to ensure that if ceph is marking OSD `down` due to flapping, OSD pod
should not restart to mark the OSDs `up` again.
This PR adds a sleep to the OSD pod if the container returned with a 0 exit code
Default behavior is to sleep for 6 hrs. But user can configure it from the
ceph cluster spec.
Signed-off-by: sp98 <sapillai@redhat.com>
While two mgrs is considered sufficient, more mgr daemons are
now allowed in case the admin wants even more fault tolerance
to the active mgr going down, in case multiple mgrs go down.
Up to five mgr pods will be allowed. All mgrs will be in
standby mode except one active mgr. All mgr pods have a sidecar
that will update their respective pod specs with the active
or passive label.
Signed-off-by: travisn <tnielsen@redhat.com>
Change how Rook detects network CIDRs for Multus networks. The IPAM
configuration is only defined as an arbitrary string JSON blob with a
"type" field and nothing more. Rook's detection of CIDRs for whereabouts
had already grown out of date since the initial implementation.
Additionally, Rook did not support DHCP IPAM, which is a reasonable
choice for users. And more, Rook did not support CNI plugin chaining,
which further complicates NADs. Based on the CNI spec, network chaning
can result in any changes to network CIDRs from the first-given plugin.
All these problems make it more and more difficult for Rook to support
Multus by inspecting the NAD itself to predict network CIDRs. Instead,
it is better for Rook to treat the CNI process as a black box. To
preserve legacy functionality of auto-detecting networks and to make
that as robust as possible, change to a canary-style architecture like
that used for Ceph mons, from which Rook will detect the network CIDRs
if possible.
Also allow users to specify overrides for CIDR ranges. This allows Rook
to still support esoteric and unexpected NAD or network configurations
where a CIDR range is not detectable or where the range detected would
be incomplete. Because it may be impossible for Rook to understand the
network CIDRs wholistically while residing only on a portion of the
network, this feature should have been present from Multus's inception.
Improving CIDR auto-detection and allowing users to specify overrides
for auto-detected CIDRs rounds out Rook's Multus support for CephCluster
(core/RADOS) installations. No further architectural changes should be
needed for CephClusters as regards application of public/cluster network
CIDRs for Multus networks.
Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
The object user was previously required to be created in the
same namespace as the object store and the cluster. Now,
the object user can be reconciled even in a different namespace
from the cluster and object store. The namespace would be specified
in the object user CR.
Signed-off-by: travisn <tnielsen@redhat.com>
If osd store is updated in the ceph cluster, then
delete OSDs one by one, cleanup disks and provision a new OSD on
the same disk
Signed-off-by: sp98 <sapillai@redhat.com>