The Snyk scan was failing on a warning with the
MPL 2.0 license, which is compatible with Rook.
Now the warnings are suppressed.
Signed-off-by: travisn <tnielsen@redhat.com>
(cherry picked from commit b718622919)
Fixes: #12930
This patch introduces a .snyk policy file that lets snyk suppress the warnings
about the MPL license in projects pulled in as dependencies.
Additinally, this fixes a typo in the name of the snyk workflow
file
Signed-off-by: Michael Adam <obnox@samba.org>
Co-authored-by: Travis Nielsen <tnielsen@redhat.com>
Co-authored-by: Blaine Gardner <b.blaine.gardner@gmail.com>
(cherry picked from commit d3bc9aafee)
krew is itself a plugin and it is wrong wording
to use krew plugin intead it should be kubectl
pluging.
Signed-off-by: subhamkrai <srai@redhat.com>
(cherry picked from commit 47c0038136)
The teardown guide is updated with the guidelines to use
third person wording and be more concise. Also, remove
the list of CRDs from the example that easily becomes
outdated as the list changes from release to release.
Signed-off-by: travisn <tnielsen@redhat.com>
(cherry picked from commit 40d4eedb83)
add view & edit ClusterRole for obc.
the roles are added to the default user facing roles
view / edit / admin respectively using k8s ClusterRole aggregation.
feature disabled for backward compatibility
and controlled with rbacAggregate.enableOBCs.
Signed-off-by: Cyril Jouve <jv.cyril@gmail.com>
(cherry picked from commit 45d897b8b3)
Update the multus canary test to reflect modern knowledge about how it
should be configured.
No longer test for the network device in OSD pods. Pods will utterly
fail to start if Multus is unable to attach interfaces.
Instead, look to the OSD map to test the connections more wholistically.
OSDs must have map IPs that include both public and cluster network.
This implicitly tests that the interfaces exist in the Pod, and it
additionally verifies other details, like Ceph `*_network` configs are
set propertly.
Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
(cherry picked from commit 3e2e906ea7)
When OSDs flap, ceph stops the OSD daemon if its marked down greater than
5 times in 600 seconds. But OSD pod restarts and marks the OSD `up` again.
This causes the PGs mapped to these OSDs to peer. While the PGs are peering,
IO to these PGs are blocked.
So we need to ensure that if ceph is marking OSD `down` due to flapping, OSD pod
should not restart to mark the OSDs `up` again.
This PR adds a sleep to the OSD pod if the container returned with a 0 exit code
Default behavior is to sleep for 6 hrs. But user can configure it from the
ceph cluster spec.
Signed-off-by: sp98 <sapillai@redhat.com>
(cherry picked from commit 4eb9f62205)
On mac development machines, the crds are being left in a
state of change with the description removed and the
OBC CRDs removed from crds.yaml and resources.yaml.
By skipping the related env vars, these resources
are no longer left unexpectedly modified.
Signed-off-by: travisn <tnielsen@redhat.com>
(cherry picked from commit 0bf117493d)
This is the latest available version.
The previously used version v2.0.0 was very outdated.
Fixes: #12883
Co-authored-by: subham rai subhamkrai <srai@redhat.com>
Signed-off-by: Michael Adam <obnox@samba.org>
Signed-off-by: Subham Rai subhamkrai <srai@redhat.com>
signed-off-by: Travis Nielsen <tnielsen@redhat.com>
Co-authored-by: Travis Nielsen <tnielsen@redhat.com>
(cherry picked from commit cef43e1155)
While two mgrs is considered sufficient, more mgr daemons are
now allowed in case the admin wants even more fault tolerance
to the active mgr going down, in case multiple mgrs go down.
Up to five mgr pods will be allowed. All mgrs will be in
standby mode except one active mgr. All mgr pods have a sidecar
that will update their respective pod specs with the active
or passive label.
Signed-off-by: travisn <tnielsen@redhat.com>
(cherry picked from commit 66547d27be)
Previously ceph-exporter would only bind to IPv4 interfaces. Now if the
CephCluster is configured with `dualStack: true` and/or `ipFamily: IPv6`
an additional flag (`--addrs ::`) will be added to the ceph-exporter
container to make it listen both IPv6 and IPv4 interfaces.
Signed-off-by: Matthew Penner <me@matthewp.io>
(cherry picked from commit d09a43df37)
For an OBC's name we cannot simply use the OBC's namespace and name,
because they can be reused, while the preceding bucket might be
retained by reclaimPolicy. (Commit 2733375ca4 also didn't solve
this issue, as it is an intra-cluster issue.) Therefore we instead
use the OBC's UID which should be unique within the cluster and
across clusters.
Signed-off-by: Sebastian Hasler <sebastian.hasler@stuvus.uni-stuttgart.de>
(cherry picked from commit 041fc1a71c)
some helm comments incorrectly indicate ceph v18 is not supported
Signed-off-by: Micah Nagel <micah.nagel@defenseunicorns.com>
(cherry picked from commit 0ff224d453)
Change how Rook detects network CIDRs for Multus networks. The IPAM
configuration is only defined as an arbitrary string JSON blob with a
"type" field and nothing more. Rook's detection of CIDRs for whereabouts
had already grown out of date since the initial implementation.
Additionally, Rook did not support DHCP IPAM, which is a reasonable
choice for users. And more, Rook did not support CNI plugin chaining,
which further complicates NADs. Based on the CNI spec, network chaning
can result in any changes to network CIDRs from the first-given plugin.
All these problems make it more and more difficult for Rook to support
Multus by inspecting the NAD itself to predict network CIDRs. Instead,
it is better for Rook to treat the CNI process as a black box. To
preserve legacy functionality of auto-detecting networks and to make
that as robust as possible, change to a canary-style architecture like
that used for Ceph mons, from which Rook will detect the network CIDRs
if possible.
Also allow users to specify overrides for CIDR ranges. This allows Rook
to still support esoteric and unexpected NAD or network configurations
where a CIDR range is not detectable or where the range detected would
be incomplete. Because it may be impossible for Rook to understand the
network CIDRs wholistically while residing only on a portion of the
network, this feature should have been present from Multus's inception.
Improving CIDR auto-detection and allowing users to specify overrides
for auto-detected CIDRs rounds out Rook's Multus support for CephCluster
(core/RADOS) installations. No further architectural changes should be
needed for CephClusters as regards application of public/cluster network
CIDRs for Multus networks.
Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
(cherry picked from commit 3c43268d0a)
Correctly set discoveryInterval default value by passing defaultDiscoverInterval to k8sutil.GetValue
Allow to set ROOK_DISCOVER_DEVICES_INTERVAL env var through discoveryDaemonInterval helm value
Signed-off-by: Louis Bailleul <louis.bailleul@pgs.com>
(cherry picked from commit e56122cbce)
It's better to move most of discover daemon setting
from env to configmap rook-ceph-operator-config.
Although, we are moving to configmap, we keep reading settings
from env but the priority will be configmap settings.
Signed-off-by: subhamkrai <srai@redhat.com>
(cherry picked from commit fb39580067)
This allows the rook mgr module to check if the discovery daemon is enabled. The udev blacklist setting was also moved just to keep similar settings in the same place.
Signed-off-by: Stephen Muth <smuth4@gmail.com>
(cherry picked from commit 37d8de0993)
The toolbox based on the operator image was added after the initial
release of v1.12.0, where the image tags from master were replaced
by hte release version. When the feature was backported,
the master tag remained. Now the version tag is set
as expected.
Signed-off-by: travisn <tnielsen@redhat.com>
This follow up the #12507
- fixes replacing of encrypted OSDs.
- Updates OSD status at the end of reconcile
Signed-off-by: sp98 <sapillai@redhat.com>
(cherry picked from commit 11b8d10a5a)
ceph-exporter's ServiceMonitor and Service CRD contain different port
name, which results in no metrics being collected by prometheus.
this commit makes GetCephMonitor configurable, which we use to set
consistent port names in ServiceMonitor and Service for ceph-exporter.
Signed-off-by: Divyansh Kamboj <dkamboj@redhat.com>
(cherry picked from commit 708dd29a97)
This simplifies the docs-check workflow definition by extracting functionality
directly coded into the workflow file into new make targets 'check-docs'
and 'check-helm-docs' and replacing the code in the workflow file by the simple invocation of
new make targets. As a side effect, it makes it easily possible for a
developer to check locally if they forgot to commit any autogenerated
docs.
Signed-off-by: Michael Adam <obnox@samba.org>
(cherry picked from commit 04670d3f76)
We need to restart all the ceph daemons whenever
cephCluster network settings are modified like
requiremsgr2, encryption and compression. This
required for Ceph to consider the new settings
it require new ceph daemons all over.
Signed-off-by: subhamkrai <srai@redhat.com>
(cherry picked from commit 29d2b6a071)
when deploying csi, we'll check if csi-addons crds
are deployed we'll enable csi-addons sidecar by default.
Signed-off-by: subhamkrai <srai@redhat.com>
(cherry picked from commit a755ec156a)