Add a section detailing a design to handle the volume-operations-blocked
on CSI restart issue when running with Multus.
See: https://github.com/rook/rook/issues/8085
Signed-off-by: Blaine Gardner <blaine.gardner@redhat.com>
(cherry picked from commit 2bf1e1f07b)
251 lines
14 KiB
Markdown
251 lines
14 KiB
Markdown
# Multus networking integration with Ceph (not finalized yet and subject to update)
|
|
|
|
We have already explored and explained the benefit of multi-homed networking, so this document will not rehearse that but simply focus on the implementation for the Ceph backend.
|
|
If you are interested in learning more about multi-homed networking you can read the [design documentation on that matter](../core/multi-homed-cluster.md).
|
|
|
|
To make the story short, [Multus](https://github.com/intel/multus-cni) should allow us to get the same performance benefit as `HostNetworking` as well as increasing the security.
|
|
Using `HostNetworking` results in exposing **all** the network interfaces (the entire stack) of the host inside the container where Multus allows you to pick the one you want.
|
|
Also, this minimizes the need of privileged containers (required for `HostNetworking`).
|
|
|
|
## Proposed CRD changed
|
|
|
|
We already have a `network` CRD property, which looks like:
|
|
|
|
```yaml
|
|
network:
|
|
provider:
|
|
selectors:
|
|
```
|
|
|
|
We will expand the `selectors` with the following two hardcoded keys:
|
|
|
|
```yaml
|
|
selectors:
|
|
public:
|
|
cluster:
|
|
```
|
|
|
|
Each selector represents a [`NetworkAttachmentDefinition`](https://github.com/intel/multus-cni/blob/master/doc/quickstart.md#storing-a-configuration-as-a-custom-resource) object in Multus.
|
|
At least, one must be provided and by default they will represent:
|
|
|
|
- `public`: data daemon public network (binds to `public_network` Ceph option).
|
|
- `cluster`: data daemon cluster network (binds to `cluster_network` Ceph option).
|
|
|
|
If only `public` is set then `cluster` will take the value of `public`.
|
|
|
|
## Multus supported configuration
|
|
|
|
### Interface type
|
|
|
|
As part of the CNI spec, Multus supports several [interface types](https://github.com/containernetworking/plugins#main-interface-creating).
|
|
Rook will naturally support any of them as they don't fundamentally change the working behavior.
|
|
|
|
### IPAM type
|
|
|
|
This is where things get more complex.
|
|
Currently there are [three different IPAM](https://github.com/containernetworking/plugins#ipam-ip-address-allocation) solutions available.
|
|
|
|
As part of our research we have found that the following IPAM types are not good candidates:
|
|
|
|
- host-local: Maintains a local database of allocated IPs, this only works on a per host basis, so not suitable for a distributed environment since we will end up with IP collision
|
|
To fix this, the [whereabouts project](https://github.com/dougbtv/whereabouts) looks promising but is not officially supported.
|
|
- static: Allocate a static IPv4/IPv6 addresses to container and it's useful in debugging purpose.
|
|
This cannot at scale because this means we will have to allocate IPs for **all** the daemon so it's not scalable.
|
|
|
|
You can find a more detailed analysis at the end of the document in the [rejected proposal section](#rejected-proposals).
|
|
|
|
## Ceph daemons implementation challenges
|
|
|
|
### Monitors and OSDs
|
|
|
|
The Ceph monitors only need access to the public network.
|
|
The OSDs needs access to both public and cluster networks.
|
|
|
|
Monitors requirements so far are the following:
|
|
|
|
- Predictable IP addresses
|
|
- Keep the same IP address for the life time of the deployment (IP should survive a restart)
|
|
|
|
### RGW implementation
|
|
|
|
Only need access to the public network.
|
|
They use service IP with a load-balancer so we need to be careful.
|
|
|
|
### MDS/RBD-MIRROR/NFS implementation
|
|
|
|
Only need access to the public network.
|
|
Nothing to do in particular since they don't use any service IPs.
|
|
|
|
### CSI pods
|
|
|
|
Steps must be taken to fix a CSI-with-multus issue documented
|
|
[here](https://github.com/rook/rook/issues/8085). To summarize the issue:
|
|
when a CephFS/RBD volume is mounted in a pod using Ceph CSI and then the CSI CephFS/RBD plugin is
|
|
restarted or terminated (e.g. by restarting or deleting its DaemonSet), all operations on the volume
|
|
become blocked, even after restarting the CSI pods. The only workaround is to restart the node where
|
|
the Ceph CSI plugin pod was restarted.
|
|
|
|
When deploying a CephCluster resource configured to use multus networks, a multus-connected network
|
|
interface will be added to the host network namespace for all nodes that will run CSI plugin pods.
|
|
This will allow Ceph CSI pods to run using host networking and still access Ceph's public multus
|
|
network.
|
|
|
|
The design for mitigating the issue is comprised of two components: a "holder" DaemonSet and a
|
|
"mover" Daemonset.
|
|
|
|
#### Holder DaemonSet and Pods
|
|
The Rook-Ceph Operator's CSI controller creates a DaemonSet configured to use the
|
|
`network.selectors.public` network specified for the CephCluster. This DaemonSet runs on all the
|
|
nodes that will have CSI plugin pods. Its pods exist to "hold" a particular network interface that
|
|
the CSI pods can reliably connect to for communication with the Ceph cluster. The process running
|
|
will merely be an infinite sleep.
|
|
|
|
These Pods should only be stopped and restarted when a node is stopped so that volume operations do
|
|
not become blocked. The Rook-Ceph Operator's CSI controller should set the DaemonSet's update
|
|
strategy to `OnDelete` so that the pods do not get deleted if the DaemonSet is updated while also
|
|
ensuring that the pods will be updated on the next node reboot (or node drain).
|
|
|
|
#### Mover DaemonSet and Pods
|
|
The Rook-Ceph Operator's CSI controller also creates a second DaemonSet configured to use host
|
|
networking. This DaemonSet also runs on all nodes that will have CSI plugin pods (and holder pods).
|
|
Mover pods exist to "move" the multus network interface being held by the holder pod on the node
|
|
into the host's network namespace to provide user's volumes with uninterrupted access to the Ceph
|
|
cluster, even when the CSI driver is restarted (or updated).
|
|
|
|
The mover must:
|
|
- be a privileged container
|
|
- have `SYS_ADMIN` and `NET_ADMIN` capabilities
|
|
- be on the host network namespace
|
|
- have access to the `/var/run/netns` directory
|
|
|
|
In order to not leave moved interfaces dangling in the host's network namespace, mover pods must
|
|
move interfaces back to their original namespace when CSI is being terminated. The most
|
|
straightforward way to accomplish this is to move interfaces back when the mover is being
|
|
terminated. If an interface is moved without user applications also being removed, this will cause
|
|
I/O disruption. Therefore, the DaemonSet should also use the `OnDelete` update strategy so that the
|
|
pods can be updated on node reboots (or node drains).
|
|
|
|
In order to better handle unexpected corner cases that leave moved interfaces in the host network
|
|
namespace (e.g., a mover is killed abruptly rather than gracefully terminated), instead treat "move"
|
|
operations as a disable-and-copy operation. To do this, disable the interface in the holder pod's
|
|
network namespace, and create a copy of the interface in the host namespace with the same MAC
|
|
address and IP config. From the user standpoint, the interface is still "moved" because the original
|
|
is disabled, so we keep the "mover" terminology. This merely helps Rook ensure that it is not
|
|
accidentally losing the original information.
|
|
|
|
A previous iteration of this design specified the mover application as a sidecar to Ceph CSI plugin
|
|
pods; however, this design would mean that the mover would need to be deleted and re-created
|
|
whenever the CSI plugin is updated, possibly resulting in I/O hangs in user pods during the update.
|
|
Keeping the mover independent allows CSI plugin updates to happen freely without complex
|
|
interactions between it and the mover.
|
|
|
|
#### Interactions between components
|
|
If a copied interface is left in the host network namespace after the holder pod is removed, multus
|
|
may later give the address to a different application, and the CSI driver may try to connect to the
|
|
different application with Ceph requests. We should try to avoid leaving interfaces on the host as
|
|
much as possible. Killing the mover pod abruptly will leave copied interfaces, but there is no way
|
|
to prevent this from happening.
|
|
|
|
If a holder pod is deleted, the interface hold will be lost. The mover must remove the
|
|
interface from the host's network namespace because multus may reassign the address to a different
|
|
application. We can document for users that they should not delete holder pods, but we cannot
|
|
prevent users from manually stopping holder pods. However, to prevent the Kubernetes scheduler from
|
|
terminating holder pods, the pods should be given the highest possible priority so that they are not
|
|
un-scheduled except by users.
|
|
|
|
There is a possible race condition where a mover pod is killed and where a holder is deleted before
|
|
a new mover starts up. In this case, the copied interface for the holder pod will be left in the
|
|
host network namespace, but the mover will not get a notification that the holder was removed. In
|
|
order to clean up from this case, upon startup, the mover should delete all interface copies in the
|
|
host network namespace that do not have a holder pod associated with them.
|
|
|
|
If the mover container is stopped, it should delete all copied interfaces in the host's
|
|
network namespace under the assumption that the CSI plugin is being removed, possibly by a
|
|
CephCluster being deleted or the node going down for maintenance. It might be possible to optimize
|
|
for the case where only the mover pod is being restarted, but it is very difficult to detect the
|
|
case where the mover is merely being restarted versus when the holder is also being removed without
|
|
possible race conditions between which pod might be stopped first by the Kubernetes API server
|
|
during a drain event. Therefore, focus on the simplest working implementation (described above)
|
|
instead of risking leaving the interface copy in host net namespace which could cause issues.
|
|
|
|
If an error occurs in the mover during network migration, it will fail and re-try migration until
|
|
the operation succeeds. If necessary, the mover will try to remove a partially-copied interface.
|
|
|
|
Restarting a node will cause the multus interface in the host namespace to go away. On restart, the
|
|
holder pod will get a new interface, and the mover will copy it into the host networking namespace again.
|
|
|
|
When a new node is added, holder and mover pods are added to it by their DaemonSets, and the
|
|
move/copy process described above occurs on the node.
|
|
|
|
The holder and mover DaemonSets should be deleted when the CSI driver components are removed. Both
|
|
the termination of the holder pods as well as the mover pods triggers the mover to remove the multus
|
|
interfaces from the host network namespace of a given node.
|
|
|
|
The initial implementation of this design will be limited to supporting a single CephCluster with
|
|
Multus until we can be sure that the CSI plugin can support multiple migrated interfaces as well as
|
|
interfaces that are added and removed dynamically. This limitation will be enforced by allowing only
|
|
a single instance of the holder DaemonSet. A possible (future) partial implementation may be
|
|
possible by restarting the CSI plugin Pods when network interfaces are added or removed.
|
|
|
|
**Known issue:** the Docker container runtime does not use Linux's native `/var/run/netns`
|
|
directory. This mitigation is known to work on cri-o runtime but not Docker. Therefore, this feature
|
|
will be disabled by default and enabled optionally by the
|
|
`ROOK_CSI_MULTUS_USE_HOLDER_MOVER_PATTERN=true` variable in the Rook-Ceph operator's config.
|
|
|
|
A previous version of the CSI proposal had the holder Pods creating "setup" and "teardown"
|
|
Kubernetes Jobs for migrating/un-migrating the multus networks. This design was rejected since new
|
|
Jobs wouldn't be able to be created if the Kubernetes namespace were in "Terminating" state.
|
|
|
|
## Accepted proposal
|
|
|
|
So far, the team has decided to go with the [whereabouts](https://github.com/dougbtv/whereabouts) IPAM.
|
|
It's an IP Address Management (IPAM) CNI plugin that assigns IP addresses cluster-wide.
|
|
If you need a way to assign IP addresses dynamically across your cluster -- Whereabouts is the tool for you. If you've found that you like how the host-local CNI plugin works, but, you need something that works across all the nodes in your cluster (host-local only knows how to assign IPs to pods on the same node) -- Whereabouts is just what you're looking for.
|
|
Whereabouts can be used for both IPv4 & IPv6 addressing.
|
|
|
|
It is under active development and is not ready but ultimately will allow to:
|
|
|
|
- Have static IP addresses distributed across the cluster
|
|
- These IPs will survive any deployment restart
|
|
- The allocation will be done by whereabouts and not by Rook
|
|
|
|
/!\
|
|
|
|
The only thing that is not solved yet is how can we predict the IPs for the upcoming monitors?
|
|
We might need to rework the way we bootstrap the monitors a little bit to not require to know the IP in advance.
|
|
|
|
## Rejected proposals
|
|
|
|
The following proposal were rejected but we keep them here for traceability and knowledge.
|
|
|
|
### IPAM type 'DHCP'
|
|
|
|
In this scenario, a DHCP server will distribute an IP address to a pod using a given range.
|
|
|
|
Pros:
|
|
|
|
- Pods will get a dedicated IP on a physical network interface
|
|
- No changes required in Ceph, Rook will detect the CIDR via the `NetworkAttachmentDefinition` then populate Ceph's flag `public_network` and `cluster_network`
|
|
|
|
Cons:
|
|
|
|
- IP allocation not predictable, we don't know it until the pod is up and running.
|
|
So the detection must append inside the monitor container is running, similarly to what the OSD code does today.
|
|
- Requires drastic changes in the monitor bootstrap code
|
|
- This adds a DHCP daemon on every part of the cluster and this has proven to be troublesome
|
|
|
|
Assuming we go with this solution, we might need to change the way the monitors are bootstrapped:
|
|
|
|
1. let the monitor discovered its own IP based on an interface
|
|
2. once the first mon is bootstrapped, we register its IP in a ConfigMap as well as populating clusterInfo
|
|
3. boot the second mon, look up in clusterInfo for the initial member (if the op dies in the process, we always `CreateOrLoadClusterInfo()` as each startup based on the cm so no worries)
|
|
4. go on and on with the rest of the monitors
|
|
|
|
TBT: if the pod restarts, it keeps the same IP.
|
|
|
|
### IPAM type 'DHCP' with service IP
|
|
|
|
We could and this is pure theory at this point use a IPAM with DHCP along with service IP.
|
|
This would require interacting with Kubeproxy and there is no such feature yet.
|
|
Even if it was there, we decided not to go with DHCP so this is not relevant.
|